• 제목/요약/키워드: calculating formula

검색결과 243건 처리시간 0.03초

2성분계 콘크리트의 구조체 보정강도(mSn) 산정을 위한 적산온도 기반 콘크리트의 압축강도 예측 연구 (A Study on the Prediction of Concrete Strength Based on Maturity Method for Calculating the Concrete Strength Correction Value (mSn) of Two-Component Concrete)

  • 김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.129-130
    • /
    • 2023
  • The compressive strength of concrete is greatly affected by the temperature inside the concrete at the initial age immediately after pouring. In the KCI Concrete Standard Specification, only the temperature correction strength (Tn) according to the curing temperature is applied in the mixing strength calculation formula, and mSn is not considered. The formula based on the Chrino model of the blast furnace slag concrete was calculated, and the strength of the structural concrete and the strength of the water cured specimen in the same mixture were compared with the predicted strength. As a result, the error between the predicted strength and the measured strength was greater in the structural concrete than in the concrete specimen.

  • PDF

비상발전기용량 산정식 개선에 관한 연구 (A Study on the Improvement of the Arithmetic for Emergency Generator Capacity)

  • 이종혁;김진오
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1517-1522
    • /
    • 2018
  • This paper describes the improvement of the arithmetic for emergency generator capacity. This formula which calculates emergency generator is dependent on the Korean Design Standard of building electrical equipment issued by the Ministry of Land, Infrastructure and Transport, and the technical data related to the generator. when appling the formula, the capacity of the generator is insufficient at the starting conditions of the load facility. In case of emergency, the generator is not operated normally. $PG_2$ of the formula ($PG_1$, $PG_2$, $PG_3$) applied in determining the capacity of the emergency generator is selected by calculating the capacity of the generator based on only biggest one motor among the load equipment and $PG_3$ may not be able to start the generator normally in case of emergency because there is an error such that the power factor is applied at the last start of the motor having the maximum capacity of the load. We analyze the problem of capacity calculation of emergency generators used for general purposes. As a consequence, the improved formulas have been presented for safety of electrical installation.

Research on axial bearing capacity of cold-formed thin-walled steel built-up column with 12-limb-section

  • Wentao Qiao;Yuhuan Wang;Ruifeng Li;Dong Wang;Haiying Zhang
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.437-450
    • /
    • 2023
  • A half open cross section built-up column, namely cold-formed thin-walled steel built-up column with 12-limbsection (CTSBC-12) is put forward. To deeply reveal the mechanical behaviors of CTSBC-12 under axial compression and put forward its calculation formula of axial bearing capacity, based on the previous axial compression experimental research, the finite element analysis (FEA) is conducted on 9 CTSBC-12 specimens, and then the variable parameter analysis is carried out. The results show the FEA is in good agreement with the experimental research, the ultimate bearing capacity error is within 10%. When the slenderness ratio is more than 96.54, the ultimate bearing capacity of CTSBC-12 decreases rapidly, and the failure mode changes from local buckling to global buckling. With the local buckling failure mode unchanged, the ultimate bearing capacity decreases gradually as the ratio of web height to thickness increases. Three methods are used for calculating the ultimate bearing capacity, the direct strength method of AISI S100-2007 gives result of ultimate axial load which is closest to the test and FEA results. But for simplicity and practicality, a simplified axial bearing capacity formula is proposed, which has better calculation accuracy with the slenderness ratio changing from 30 to 100.

Performance Analysis of a Loss Retrial BMAP/PH/N System

  • Kim Che-Soong;Oh Young-Jin
    • 한국산업정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.32-37
    • /
    • 2004
  • This paper investigates the mathematical model of multi-server retrial queueing system with the Batch Markovian Arrival Process (BMAP), the Phase type (PH) service distribution and the finite buffer. The sufficient condition for the steady state distribution existence and the algorithm for calculating this distribution are presented. Finally, a formula to solve loss probability in the case of complete admission discipline is derived.

  • PDF

Conditions for No Soil -Push By Outside of Front Cutting Surface on Bent Blade

  • Chen, Cuiying;Mao, Hanping
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1088-1094
    • /
    • 1993
  • One of the important restraint conditions for determination of rotary tiller parameters is whether the outside of front cutting surface on blade in rotary tiller pushes untilled soil in operation. By theoretical analysis and graphic verification on computer, no sil-push conditions is put forward and formula for calculating the position angle of its bent line derived, as is convenient for selection of rotary tiller parameters and design and drawing of its blade.

  • PDF

The Optimal Condition for Velocity Modulation

  • Park, Joon-Suk;Kim, Do-Nyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1157-1159
    • /
    • 2003
  • The effect of the scan velocity modulation is studied. The effect of the velocity modulation on the picture image is judged from the intensity profile of the image. The intensity profile is obtained as time integral of moving Gaussian beam. To confirm the applicability of this integral formula, the measurement and simulation data is compared. And by calculating the intensity profile for different amounts of velocity modulation, the optimum modulation displacement that gives the best image quality is obtained. This optimum modulation displacement can be used in designing scan velocity modulation system.

  • PDF

A NOVEL MERHOO AND PROCEDURE FOR ON-LINE MEASUREMENT OF FLUID PROPERTIES FOR CONTROL AND OPTIMIZATION

  • Kaya, Azmi;Keyes, Marion-A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.844-847
    • /
    • 1989
  • This work describes an on-line method and procedure for calculating the fluid properties in real time while system is in operation. The method utilizes function blocks of distributed control systems. Thermodynamic relations of fluid from tables along with a fluid property formula are imbedded into the proposed signal processing block. Once the pressure and temperature measurements are entered the system provides other properties.

  • PDF

On an Approximation for Calculating Multivariate t Orthant Probabilities

  • Hea Jung Kim
    • Communications for Statistical Applications and Methods
    • /
    • 제4권3호
    • /
    • pp.629-635
    • /
    • 1997
  • An approximation for multivariate t probability for an orhant region(i.e., a rectangular resion with lower limits of $-\infty$ for all margins) is proposed. It is based on conditional expectations, a regression with binary variables, and the exact formula for the evalution of the bivariate t integrals by Dunnett and Sobel. It is noted that the proposed approximation method is espicially useful for evaluating the multivariate t integrals where there is no simple method available until now.

  • PDF

가공배전선에 의한 유도전압 특성 분석 (An Analysis of the Induced Voltage characteristic on 22.9kV-Y Distribution Lines)

  • 임용훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.500-502
    • /
    • 2003
  • This paper reviews calculating of induced voltage onto a communication line from 22.9kV-Y Distribution Lines. The coexistence of both power line and communication line in parallel generates the induction of significant longitudinal voltage in the weak current line. In order to evaluate a precise induced voltage, this paper indicated some problems about coefficient and numerical formula. It also presents some induced voltage production technology standard application.

  • PDF