• Title/Summary/Keyword: caisson-type

Search Result 62, Processing Time 0.031 seconds

Vibration Response Analysis of Gravity-type Caisson Breakwater (중력식 케이슨 방파제의 진동응답 분석)

  • Lee, So-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae;Han, Sang-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.91-96
    • /
    • 2013
  • In this paper, vibration response of gravity-type caisson breakwater is analyzed to suggest the direction for structural health monitoring (SHM) on harbor caisson structure. To achieve the objective, the following approaches are implemented. Firstly, vibration analysis methods are selected to examine the dynamic characteristics of the lab-scale caisson in the frequency and the modal domain. Secondly, vibration tests on the lab-scale caisson breakwater which is installed in 2-D wave tank were performed under several water level conditions. Thirdly, vibration response of the lab-scale caisson were analyzed in the frequency and modal domain. Finally, the direction of SHM for gravity-type caisson breakwater was suggested.

  • PDF

Vibration-based Structural Health Monitoring of Caisson-type Breakwaters Damaged on Rubble Mound (사석마운드가 손상된 케이슨식 방파제의 진동기반 구조건전성 모니터링)

  • Lee, So-Young;Kim, Jeong-Tae;Kim, Heon-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2010
  • In this paper, vibration-based structural health monitoring methods that are suitable for caisson-type structures are examined by an experimental evaluation. To achieve the objective, four approaches are implemented. First, vibration-based structural health monitoring methods are selected to monitor the structural condition of caisson-type breakwaters. Second, a lab-scaled caisson structure is constructed to verify the selected monitoring methods. Third, the vibration characteristics are numerically analyzed using an FE model due to the change in the rubble mound condition. Finally, experimental vibration tests of the lab-scaled caisson structure are performed to monitor the vibration responses due to changes in rubble mound conditions and the performances of the selected methods are examined from the monitoring results.

Structural identification of gravity-type caisson structure via vibration feature analysis

  • Lee, So-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.259-281
    • /
    • 2015
  • In this study, a structural identification method is proposed to assess the integrity of gravity-type caisson structures by analyzing vibration features. To achieve the objective, the following approaches are implemented. Firstly, a simplified structural model with a few degrees-of-freedom (DOFs) is formulated to represent the gravity-type caisson structure that corresponds to the sensors' DOFs. Secondly, a structural identification algorithm based on the use of vibration characteristics of the limited DOFs is formulated to fine-tune stiffness and damping parameters of the structural model. Finally, experimental evaluation is performed on a lab-scaled gravity-type caisson structure in a 2-D wave flume. For three structural states including an undamaged reference, a water-level change case, and a foundation-damage case, their corresponding structural integrities are assessed by identifying structural parameters of the three states by fine-tuning frequency response functions, natural frequencies and damping factors.

Shaking Table Tests for Evaluation of Seismic Performance of L-type Caisson Quay Walls (L형 케이슨 안벽 구조물의 내진성 평가를 위한 진동대 시험)

  • 한진태;황재익;이용재;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.148-156
    • /
    • 2003
  • Shaking table tests and pseudo-static analysis were performed, in this study, on newly-designed aseismatic L-type caisson quay walls, which were constructed by extending the bottom plate of gravity quay walls into the backfill soil. The L-type quay walls are expected to give economical benefits by reducing the cross-sectional area of the wall while maintaining its aseismatic efficiency as much as the classical caisson gravity quay wall. To confirm the effectiveness of the L-type structure, the geometry of L-type quay walls were varied for shaking table tests. And, to verify the influence of backfill soils on the seismic behavior of quay walls, additional shaking table tests were performed on the L-type quay wall after the backfill soils were replaced by gravels and light materials. As a result, it was found that L-type caisson quay walls are good earthquake resistant structures but increasing the length of bottom plate did not proportionally increase the effectiveness of the structure in its aseismatic performance. Replacing the backfill soils by the gravels and light materials, contrary to our expectation, was not an effective measure in improving the seismic performance of L-type caisson quay wall.

  • PDF

Seismic behavior of caisson-type gravity quay wall renovated by rubble mound grouting and deepening

  • Kim, Young-Sang;Nguyen, Anh-Dan;Kang, Gyeong-O
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.447-463
    • /
    • 2021
  • Caisson-type structures are widely used as quay walls in coastal areas. In Korea, for a long time, many caisson-type quay walls have been constructed with a low front water depth. These facilities can no longer meet the requirements of current development. This study developed a new technology for deepening existing caisson-type quay walls using grouting and rubble mound excavation to economically reuse them. With this technology, quay walls could be renovated by injecting grout into the rubble mound beneath the front toe of the caisson to secure its structure. Subsequently, a portion of the rubble mound was excavated to increase the front water depth. This paper reports the results of an investigation of the seismic behavior of a renovated quay wall in comparison to that of an existing quay wall using centrifuge tests and numerical simulations. Two centrifuge model tests at a scale of 1/120 were conducted on the quay walls before and after renovation. During the experiments, the displacements, accelerations, and earth pressures were measured under five consecutive earthquake input motions with increasing magnitudes. In addition, systematic numerical analyses of the centrifuge model tests were also conducted with the PLAXIS 2D finite element (FE) program using a nonlinear elastoplastic constitutive model. The displacements of the caisson, response accelerations, deformed shape of the quay wall, and earth pressures were investigated in detail based on a comparison of the numerical and experimental results. The results demonstrated that the motion of the caisson changed after renovation, and its displacement decreased significantly. The comparison between the FE models and centrifuge test results showed good agreement. This indicated that renovation was technically feasible, and it could be considered to study further by testbed before applying in practice.

Displacement Charateristics of Caisson-Type Breakwater under Earthquake Loadings (지진하중을 받는 케이슨 방파제의 변위 특성분석)

  • Shin, Eun-Chul;Jeon, Jae-Ku;Lee, Joong-Hwa;Lee, Chung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1258-1270
    • /
    • 2009
  • Recently, the earthquakes activities are more of frequency occurred in the country. In case of nomal or large magnitude earthquakes, which cause a rising number of life loss or widespread loss of property. It must be considered how to cope with the situperty of dpmage in the country ty account of ay earthquake. Consequently, the public works have currently ensured against a lot of risk about seismism not only on large scale structures but also relatively small structures. Therefore, in this study, in order to make the seismic stability safe, it has been evaluated by the seismic performance for caisson-type breakwater. The seismic response analyses have conducted on the caisson-type breaker under long-period, short-period and artificial seismic wave. The liquefaction potential of the foundation, which is caisson-type, is also estimated by using the simplified assessment method. Finally, the result of the numerical analysis by PENTAGON 2D finite element method(FEM) program are presented for 3 cases with time-history seismic analysis under the seismic load.

  • PDF

Probabilistic Seismic Hazard Analysis of Caisson-Type Breakwaters (케이슨 방파제의 확률론적 지진재해도 평가)

  • KIM SANG-HOON;KIM DOO-KIE
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.1 s.62
    • /
    • pp.26-32
    • /
    • 2005
  • Recent earthquakes, measuring over a magnitude of 5.0, on the eastern coast of Korea, have aroused interest in earthquake analyses and the seismic design of caisson-type breakwaters. Most earthquake analysis methods, such as equivalent static analysis, response spectrum analysis, nonlinear analysis, and capacity analysis, are deterministic and have been used for seismic design and performance evaluation of coastal structures. However, deterministic methods are difficult for reflecting on one of the most important characteristics of earthquakes, i.e. the uncertainty of earthquakes. This paper presents results of probabilistic seismic hazard assessment(PSHA) of an actual caisson-type breakwater, considering uncertainties of earthquake occurrences and soil properties. First, the seismic vulnerability of a structure and the seismic hazard of the site are evaluated, using earthquake sets and a seismic hazard map; then, the seismic risk of the structure is assessed.

Dynamic response analysis of the caisson-type quay wall using the wavelet transform (웨이브렛 변환을 이용한 케이슨식 안벽의 동적응답해석)

  • Moon, Yong;Kim, Jae-Kwon;Shin, Hyun-Yang;Seok, Jeong-Woo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.74-81
    • /
    • 2003
  • During the 1995 Hyogoken-Nambu earthquake, many caisson-type quay walls in Kobe Port moved several meters towards the seaside due to liquefaction and subsequent ground flow, To investigate the mechanism of quay wall damage, we carried out the numerical simulation using the 2-D effective stress analysis. Input earthquake motions used for the analyses are original Dip wave and the component wave in each compact support of wavelet transformation. The results suggested that the shear failure occurred in the foundation soil underneath the caisson type quay wall due to the deformation of the caisson type quay wall.

  • PDF

Experimental Modal Analysis for Damage Identification in Foundation-Structure Interface of Caisson-type Breakwater (케이슨식 방파제 지반-구조 경계부 손상식별을 위한 실험적 모드분석)

  • Lee, So-Young;Lee, So-Ra;Kim, Jeong-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • This paper presents an experimental modal analysis of a caisson-type breakwater to produce basic information for the structural health assessment of a caisson structure. To achieve the objective, the following approaches are implemented. First, modal analysis methods are selected to examine the modal characteristics of a caisson structure. Second, experimental modal analyses are performed using finite element analyses and lab-scale model tests. Third, damage scenarios that include several damage levels in a foundation-structure interface are designed. Finally, the effects of damage on the modal characteristics are analyzed for the purpose of utilizing them for damage identification.

Reliability Analysis of Caisson Type Breakwater using Load Surface (하중면을 이용한 케이슨식 방파제의 신뢰성해석)

  • Kim, Dong-Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.3
    • /
    • pp.209-215
    • /
    • 2009
  • A new load surface method for reliability of caisson type breakwater was proposed. Linear functions for horizontal wave force and uplift force were estimated by using water level and wave height then they were applied to the reliability analysis of breakwater using first order reliability method(FORM). In the numerical example, sliding and overturning failure probability of caisson type breakwater were analyzed by using load surface and they were compared with those by Monte Carlo simulation.