• 제목/요약/키워드: cadmium telluride(CdTe)

검색결과 41건 처리시간 0.032초

Photoluminescience properties for CdIn2Te4 single crystal grown by Bridgman method

  • Hong, Myung-Seok;Hong, Kwang-Joon;Kim, Jang-Bok
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.379-385
    • /
    • 2006
  • Single crystal of p-$CdIn_{2}Te_{4}$ was grown in a three-stage vertical electric furnace by using Bridgman method. The quality of the grown crystal has been investigated by x-ray diffraction and photoluminescence measurements. From the photoluminescence spectra of the as-grown $CdIn_{2}Te_{4}$ crystal and the various heat-treated crystals, the ($D^{o}$, X) emission was found to be the dominant intensity in the photoluminescence spectrum of the $CdIn_{2}Te_{4}$:Cd, while the ($A^{o}$, X) emission completely disappeared in the $CdIn_{2}Te_{4}$:Cd. However, the ($A^{o}$, X) emission in the photoluminescence spectrum of the $CdIn_{2}Te_{4}$:Te was the dominant intensity like in the as-grown $CdIn_{2}Te_{4}$ crystal. These results indicated that the ($D^{o}$, X) is associated with $V_{Te}$ which acted as donor and that the ($A^{o}$, X) emission is related to $V_{Cd}$ which acted as acceptor, respectively. The p-$CdIn_{2}Te_{4}$ crystal was obviously found to be converted into n-type after annealing in Cd atmosphere. The origin of ($D^{o},{\;}A^{o}$) emission and its to phonon replicas is related to the interaction between donors such as $V_{Te}$ or $Cd_{int}$, and acceptors such as $V_{Cd}$ or $Te_{int}$. Also, the In in the $CdIn_{2}Te_{4}$ was confirmed not to form the native defects because it existed in a stable bonding form.

이온성 액체를 이용한 수계 양자 점 합성 (Aqueous synthesis of quantum dots using functionalized ionic liquid)

  • 최숙영;김태영;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.254-254
    • /
    • 2010
  • We report aqueous synthesis of cadmium telluride (CdTe) quantum dots(QDs) using imidazolium-based ionic liquids with various functional groups. The functinalized ionic liquids were designed to have thiol groups, and then phase transfer with aqueous or organic solvents can be adjusted by changing side chain lengths of the cation and the choice of anion. The quantum yield was obtained IL-functionalized CdTe QDs reached up to 40% by post-treatment method.

  • PDF

Passivation effect on large volume CdZnTe crystals

  • B. Park;Y. Kim;J. Seo;J. Byun;K. Kim
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4620-4624
    • /
    • 2022
  • Several cadmium zinc telluride (CZT) crystals were fabricated into radiation detectors using methods that included slicing, dicing, lapping, polishing, and chemical etching. A wet passivation with sodium hypochlorite (NaOCl) was then carried out on the Br-etched detectors. The Te-rich layer on the CZT surface was successfully compensated to the Te oxide layer, which was analyzed with X-ray photoelectron spectroscopy data of both a Br-etched crystal and a passivated CZT crystals. We confirmed that passivation with NaOCl improved the transport property by analyzing the mobility-lifetime product and surface recombination velocity. The electrical and spectroscopic properties of large volume detectors were compared before and after passivation, and then the detectors were observed for a month. Both bar and quasi-hemispherical detectors show an enhancement in performance after passivation. Thus, we could identify the effect of NaOCl passivation on large volume CZT detectors.

Bridgman법에 의해 $CdIn_2Te_4$ 단결정 성장과 광발광 특성 (Photoluminescience Properties and Growth of $CdIn_2Te_4$ Single crystal by Bridgman method)

  • 홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.278-281
    • /
    • 2003
  • The p-CIn2Te4 single crystal was grown in the three-stage vertical electric furnace by using Bridgman method. The quality of the grown crystal has been investigated by the x-ray diffraction and the photoluminescence measurements. From the photoluminescence spectra of the as-grown CdIn2Te4 crystal and the various heat-treated crystals, the (Do, X) emission was found to be the dominant intensity in the photoluminescence spectrum of the CdIn2Te4:Cd, while the (Ao, X) emission completely disappeared in the CdIn2Te4:Cd. However, the (Ao, X) emission in the photoluminescence spectrum of the CdIn2Te4:Te was the dominant intensity like an as-grown CdIn2Te4 crystal. These results indicated that the (Do, X) is associated with VTe acted as donor and that the (Ao, X) emission is related to VCd acted as acceptor, respectively. The p-CdIn2Te4 crystal was found to be obviously converted into the n-type after annealing in the Cd atmosphere. The origin of (Do, Ao) emission and its TO phonon replicas is related to the interaction between donors such as VTe or Cdint, and accepters such as VCd or Teint. Also, the In in the CdIn2Te4 was confirmed not to form the native defects because it existed in the stable form of bonds.

  • PDF

빛을 이용한 CdTe 나노입자의 자기조립과정을 통한 나노리본으로의 변화 (Transformation of Semiconductor Nanoparticles into Twisted-Nanoribbons under Light)

  • 이승민;이기선;홍연기;박병흥;김기섭
    • 융복합기술연구소 논문집
    • /
    • 제3권1호
    • /
    • pp.51-54
    • /
    • 2013
  • Cadmium telluride(CdTe) nanowires were successfully synthesized from individual nanoparticles via self-assembly and the evolutionary process was investigated. The oxidation of tellurium ions on CdTe nanoparticles resulted in the organization of individual nanoparticle into twisted-nanoribbons. The nanoparticles self-assembled to twisted ribbons under light while nanoparticles under dark transformed to straight nanowires made of several layers of individual nanoparticles. The images of nanoribbons were analysed based on transmission electron microscopy and scanning electron microscopy. The photoluminescence was blue-shifted from 555 to 545nm.

  • PDF

대면적 기판에 균일한 CdTe 박막 증착을 위한 스퍼터링 방법 연구 (A Study on Sputtering Method for Uniform Deposition of CdTe Thin Film on Large-area Substrates)

  • 박주선;임채현;류승한;김남훈;양정태;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1264_1265
    • /
    • 2009
  • Cadmium Telluride (CdTe)를 이용한 박막형 태양전지 제작과 실용화에 있어 가장 큰 이슈는 대면적화에 따른 에너지 변환효율의 저하를 줄임으로써 고효율의 대면적 태양전지를 대량으로 생산하는 것이다. 따라서 본 연구에서는 태양전지 박막의 대면적 증착시 문제점 중에 하나인 불균일한 CdTe 박막의 증착을 방지하기 위한 선행연구를 진행하였다. 실험 방법으로는 Sputtering 법을 적용하여 박막 증착시 출력과 진공도에 따른 박막 두께의 표준편차와 RMS 표면 거칠기($R_{rms}$), 최고-최저점간 표면 거칠기($R_{p-v}$) 등의 거동을 고찰하였다. 이를 통해 Sputtering 공정 변수 중에 박막 두께의 표준 편차에 더 큰 영향을 미치는 변수를 조사하고, 후행 연구로 진행될 Sputtering 법을 이용하여 대면적에 균일하게 증착하는 방법에 적용하고자 한다.

  • PDF

Energy separation and carrier-phonon scattering in CdZnTe/ZnTe quantum dots on Si substrate

  • 만민탄;이홍석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.191.2-191.2
    • /
    • 2015
  • Details of carrier dynamics in self-assembled quantum dots (QDs) with a particular attention to nonradiative processes are not only interesting for fundamental physics, but it is also relevant to performance of optoelectronic devices and the exploitation of nanocrystals in practical applications. In general, the possible processes in such systems can be considered as radiative relaxation, carrier transfer between dots of different dimensions, Auger nonradiactive scattering, thermal escape from the dot, and trapping in surface and/or defects states. Authors of recent studies have proposed a mechanism for the carrier dynamics of time-resolved photoluminescence CdTe (a type II-VI QDs) systems. This mechanism involves the activation of phonons mediated by electron-phonon interactions. Confinement of both electrons and holes is strongly dependent on the thermal escape process, which can include multi-longitudinal optical phonon absorption resulting from carriers trapped in QD surface defects. Furthermore, the discrete quantized energies in the QD density of states (1S, 2S, 1P, etc.) arise mainly from ${\delta}$-functions in the QDs, which are related to different orbitals. Multiple discrete transitions between well separated energy states may play a critical role in carrier dynamics at low temperature when the thermal escape processes is not available. The decay time in QD structures slightly increases with temperature due to the redistribution of the QDs into discrete levels. Among II-VI QDs, wide-gap CdZnTe QD structures characterized by large excitonic binding energies are of great interest because of their potential use in optoelectronic devices that operate in the green spectral range. Furthermore, CdZnTe layers have emerged as excellent candidates for possible fabrication of ferroelectric non-volatile flash memory. In this study, we investigated the optical properties of CdZnTe/ZnTe QDs on Si substrate grown using molecular beam epitaxy. Time-resolved and temperature-dependent PL measurements were carried out in order to investigate the temperature-dependent carrier dynamics and the activation energy of CdZnTe/ZnTe QDs on Si substrate.

  • PDF

근접승화법을 이용한 CdTe박막의 성장에 관한 연구 (A Study on the Growth of CdTe Films by Close-Spaced Sublimation)

  • 이민석;허주열;김동환
    • 한국재료학회지
    • /
    • 제8권5호
    • /
    • pp.383-393
    • /
    • 1998
  • 고효율 박막형 태양전지 제조를 위해 근접승화법에 의한 CdTe박막의 성장을 연구하였다. 내부압력의 변화, 기판과 소스 사이의 거리, 기판과 소스의 온도 등의 변수가 성장속도와 미세구조에 미치는 영향을 관찰했다. 내부압력의 변화에 따라 성장과정이 diffusion limited transport와 sublimation limited transport로 나뉘어지며, 이 두가지 성장방식의 분기점은 기체분자의 평균자유행정거리에 의해 결정되었다. 소스의 형태에 따라서 박막의 성장속도와 미세구조는 큰 차이를 보였으며, 실험을 통해 이러한 차이가 증발표면의 온도강하에 의한 현상임을 규명하였다. 기판과 소스사이의 간격에 따른 성장속도를 해석하기 위해 일방향열해석을 통해 기판과 소스표면의 온도를 계산하였다. X선 회절분석과 표면형상의 관찰을 통해 성장속도가 박막의 미세구조에 영향을 줌을 알았다. 기판의 온도가 증가하면서 박막성장시 (111)로의 우선성장방위가 관찰되었지만 고온이 되면서 다시 random orientation의 경향을 나타냈다.

  • PDF

Low-temperture Synthesis of CdTe/Te Core-shell Hetero-nanostructures by Vapor-solid Process

  • 송관우;김태훈;배지환;이재욱;박민호;양철웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.580-580
    • /
    • 2012
  • Heterostructures has unique and important properties, which may be helpful for finding many potential applications in the field of electronic, thermoelectric, and optoelectronic devices. We synthesized CdTe/Te core-shell heterostructures by vapor-solid process at low temperatures using a quartz tube furnace. Two step vapor-solid processes were employed. First, various tellurium structures such as nanowires, nanorods, nanoneedles, microtubes and microrods were synthesized under various deposition conditions. These tellurium nanostructures were then used as substrates in the second step to synthesize the CdTe/Te core-shell heterostructures. Using this method, various sizes, shapes and types of CdTe/Te core-shell structures were fabricated under a range of conditions. These structures were analysed by scanning electron microscopy, high resolution transmission electron microscopy, and energy dispersive x-ray spectroscopy. The vapor phase process at low temperatures appears to be an efficient method for producing a variety of Cd/Te hetero-nanostructures. In addition, the hetero-nanostructures can be tailored to the needs of specific applications by deliberately controlling the synthetic parameters.

  • PDF

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.