• 제목/요약/키워드: cable tunnel

검색결과 200건 처리시간 0.028초

알루미네이트계 급결제를 사용한 숏크리트의 산침식에 대한 저항성 평가 (Evaluation on the Acid Attack Resistance of Shotcrete with Aluminate Accelerator)

  • 김성수;김홍삼;김동규;윤하영;봉원용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.249-252
    • /
    • 2006
  • Recently, as it has greatly increased the demand on the serviceability of subway, cable tunnel and underground storage, the stability of tunnel structures has been attracting the concern of engineers and researchers. Thus the aim of the present study is to evaluate acid attack resistance of shotcrete using in tunnel structures. And, in order to understand the deterioration mechanism, test using scanning electron microscopy(SEM) analysis and X-ray diffraction showed that the deterioration mechanism due to acid attack in shotcrete.

  • PDF

전력구 내부온도 예측 및 최적냉각설계에 관한 연구 (Study on The Underground tunnel Cooling System)

  • 김민주;강연욱;장태인;강지원;김두진;윤종건;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.424-425
    • /
    • 2015
  • In the underground cable tunnel, The transmission efficient is lowered due to the local heating region. In this reason, the cooling system is needed. For adapting the cooling system, Preceding study on the factor of increasing temperature in the underground tunnel is essential. In this paper optimal cooling system suggest.

  • PDF

불확실성을 고려한 다중요소 의사 결정기반의 지중전력구 감시 및 진단 (Power Tunnel Monitoring and Diagnosis Based On Multiple Attribute Making Decision with Uncertainty)

  • 이지혜;김상태;이지훈;김종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.349-350
    • /
    • 2015
  • Traditional power tunnel monitoring and diagnosis system provides simple alert in accordance with limits which set by operator using various field installed various sensor measurements. System's algorithm is too simple and it has uncertainty of sensor with error. In this paper, proposed algorithm give operator verification using installed sensor measurements such as environmental sensors for fire prevention because of cable overheat in the power tunnel.

  • PDF

강 사장교 가설 중 임시 제진방법에 대한 풍동실험 연구 (Wind Tunnel Aeroelastic Studies of Steel Cable-stayed Bridge with Wind Cable and Temporary Support)

  • 조재영;심종한;이학은;권오훈
    • 한국강구조학회 논문집
    • /
    • 제18권1호
    • /
    • pp.33-45
    • /
    • 2006
  • 일반적으로 사장교와 같은 장대교량은 완성 후에 비하여 시공 중 바람에 흔들리기 쉬어 내풍 안정성 문제가 발생하는 경우가 많다. 완공상태에서 충분한 내풍안정성을 확보하고 있더라도 시공단계에서는 설계풍속 이하에서 플러터 등의 공기역학적 진동현상 이 발생하는 경우가 많기 때문에 가설공법이 결정되면 반드시 풍동실험을 능한 적절한 제진 대책 안을 입안해 두어야 한다. 본 연구에서는 가설단계를 고려한 3차원 전교모형실험을 통하여 주경간이 500m인 사장교의 공기역학적 거동을 살펴보았다. 작업 중에 안정성 확보가 중요한 밸런스드 캔틸레버 상태인 가설단계 50% 에서 내풍케이블 및 가설벤트를 이용한 4가지 제진 대책방안을 수립하여 각각에 대하여 내풍 안정성을 검토하였다. 각 설치방안 별 제진효과를 서로 비교 분석하여 검토 범위 내에서 사장교 시공 중 가장 효율적인 임시 제진방안을 제시하였다. 추가적으로 밸런스드 캔틸레버 상태와의 내풍안정성을 비교하기 위하여 완성계와 제진 대책이 없는 주경간 폐합전의 프리캔틸레버 상태에 대하여 살펴보았다.

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

지중무선 시스템을 이용한 침매터널 구간 계측관리 사례연구 (Case Study of Immersed Tunnel Instrumentation Management Using Wireless System)

  • 한상욱;김병희;한병원;이계춘
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.768-773
    • /
    • 2009
  • Measuring method being applied for off-shore works is performed by using data logger or manual measuring instrument with wiring the cable connected from the sensor up to the position where measuring is allowed.(upper part of embankment or marine structure) Measuring management by using existing measuring method may be acceptable on the condition that the ground deformation volume(vertical, horizontal) is generally minimal and the site condition is good. But loss of measuring instrument, sensor cable failure or cutting is taken place frequently due to significant change of ground behavior caused by an external force change(embankment, excavation) under very soft ground condition(N value below 0-4). In case of the marine works, in particular, loss rate of measuring instrument is highly represented due to the factors of working barge anchoring, constructional interference and natural disaster. In order to solve these problems, measuring management was performed with employing underground wireless system at the immersed tunnel site. Measuring data was obtained freely under the marine environment by using underground wireless communication and cable cutting potential by ground behavior could be reduced. Measuring cost savings and its installation convenience were maximized by way of off-shore tower installation or cabling and by minimizing constructional interference of off-shore working barge. This case of measuring management was accomplished successfully.

  • PDF

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;김유성;송윤호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

The aerodynamic characteristics of twin column, high rise bridge towers

  • Ricciardelli, Francesco;Vickery, Barry J.
    • Wind and Structures
    • /
    • 제1권3호
    • /
    • pp.225-241
    • /
    • 1998
  • The high-rise supporting towers of long-span suspension and cable-stayed bridges commonly comprise a pair of slender prisms of roughly square cross-section with a center-to-centre spacing of from perhaps 2 to 6 widths and connected by one or more cross-ties. The tower columns may have a constant spacing as common for suspension bridges or the spacing may reduce towards the top of the tower. The present paper is concerned with the aerodynamics of such towers and describes an experimental investigation of the overall aerodynamic forces acting on a pair of square cylinders in two-dimensional flow. Wind tunnel pressure measurements were carried out in smooth flow and with a longitudinal intensity of turbulence 0.10. Different angles of attack were considered between $0^{\circ}$ and $90^{\circ}$, and separations between the two columns from twice to 13 times the side width of the column. The mean values of the overall forces proved to be related to the bias introduced in the flow by the interaction between the two cylinders; the overall rms forces are related to the level of coherence between the shedding-induced forces on the two cylinders and to their phase. Plots showing the variation of the force coefficients and Strouhal number as a function of the separation, together with the force coefficients spectra and lift cross-correlation functions are presented in the paper.

전력구의 지진응답해석법에 사용되는 응답변위법의 보수성 평가 (Conservativeness of Response Displacement Method used in Seismic Response Analysis of Power Cable Tunnels)

  • 임재성;양대승;황경민;김재민
    • 한국전산구조공학회논문집
    • /
    • 제34권4호
    • /
    • pp.243-254
    • /
    • 2021
  • 이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답변위법(Response Displacement Method, RDM)의 보수성을 평가하였다. 이를 위하여 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답변위법에 의한 해석은 다음과 같은 세 가지 방법을 적용하였다: (1) 단일코사인방법, (2) 이중코사인방법, (3) 부지응답해석법. 그리고 이들 응답변위법의 보수성을 평가하기 위하여 지반-구조물 상호작용을 고려한 동적해석법으로 구한 응답과 비교하였다. 비교결과, 설계지진력을 결정하는 방법 중에서 부지응답해석법이 가장 변동폭이 작았으며, 이중코사인방법이 가장 보수적인 결과를 보였다. 마지막으로 이중코사인방법을 적용할 때, 응답변위법에 의한 부재력이 동적해석에 의한 값보다 클 확률이 80% 이상이 되기 위한 지반강성 보정계수 C값으로 기능수행수준에서 0.9, 붕괴방지수준에서 0.7을 추천하였다.

실대형 하중재하 시험 및 현장계측을 통한 쉴드터널 세그먼트 안정성 분석 (Stability analysis of shield tunnel segment lining by field measurement and full scale bending test)

  • 이규필;장수호
    • 한국터널지하공간학회 논문집
    • /
    • 제21권5호
    • /
    • pp.611-620
    • /
    • 2019
  • 쉴드터널은 직경 3~4 m 규모의 전력구 등에 주로 적용되었으나, 최근 직경 7~8 m 규모의 쉴드터널이 인천국제공항 활주로 하부에 시공되었으며, 한강 하저구간 도로 및 철도터널 시공완료 및 계획중에 있다. 쉴드터널 단면이 증가함에 따라 세그먼트 또한 대형화되고 있으며, 이로 인하여 세그먼트의 설계, 시공 및 성능평가 시 여러 문제점이 야기되고 있다. 따라서 본 연구에서는 직경 약 8 m 규모의 쉴드터널에 대한 현장계측 및 실대형 하중재하 시험을 통하여 쉴드터널 세그먼트 라이닝 구조적 안정성 분석, 축력을 고려한 세그먼트 사용성 검토방안의 적합성 및 품질관리 방안에 대하여 검토하였다.