• 제목/요약/키워드: cBPM

Search Result 29, Processing Time 0.022 seconds

The Study of the SOA Enabled ERP Systems Implementation in Service Industry: Case Study

  • Kim, Gyu-C.
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.1
    • /
    • pp.73-93
    • /
    • 2012
  • The primary objective of this research is to explain how to implement the Service Oriented Architecture (hereafter SOA) enabled Enterprise Resource Planning (hereafter ERP) system successfully for service industries. An implementation of the ERP system help many organizations to alleviate the difficult job of supporting inflexible or legacy systems that in most cases result in cost increases, data redundancy and inaccuracy, and various inefficiencies. However, the ERP system is losing its market share rapidly to the cloud computing system which utilizes the Software-as-a-service (hereafter SaaS) and SOA. The SOA is an approach to integrate various types of IT resources to leverage existing ERP system, while at the same time building an infrastructure that can readily respond to new business environment and offer new dynamic applications. The companies that implement this system have less of a need for the kinds of all-in-one ERP system that have dominated the back office for decades and can move freely to best-of-breed applications. This research will identify the benefits and costs of the SOA enabled ERP system through case studies and its impact on competitive priorities such as cost, quality, delivery, and flexibility.

Analysis of Intermolecular Interaction in Thermotropic Aromatic Polyurethanes with Flexible Spacers (Spacer를 가지고 방향족 polyurethane의 분자간 상호 작용에 의한 액정성의 발견)

  • Lee, Jong Back;Song, Jin Cherl
    • Textile Coloration and Finishing
    • /
    • v.7 no.4
    • /
    • pp.8-15
    • /
    • 1995
  • A series of thermotropic Polyurethanes mesogenic unit were synthesized by polyaddition of a para-type diisocyanate such as 2,5-tolylene diisocyanate(2,5-TDI) with 4-4'-bis($\omega$-hydroxyalkoxy) biphenls(BPm: $HOCmH_{2m}OC_{6}H_{4}OC_{m}H_{2m}OH$ : m is the carbon number of the hydroxyalkoxy group) in DMF. Intrinsic viscosities of the polymers were in the range of 0.41~0.99dL/g DSC thermograms for these polymers exhibited two endothermic peaks corresponding to phase transitions of melting and isotropization. For examplem polyurethane 2,5-TDI/BPll with [η]=0.99 prepared from 2.5-TDI and 4,4'-bis[11-hydroxyundecaoxy biphenyl(BP11) a liquid crystalline phase from 156 to 173$^{\circ}C$. The thermotropic properites of liquid crystalline polyurethanes have been investigated by wide-angle X-ray scatter(WAXS), infrared (IR) spectroscopy, and differential scanning calorimetry (DSC). The mesomorphic behavior of the polyurethanes was concluded to be greatly dependent on the intermolecular hydrogen bonds through the urethane.

  • PDF

Performance of CWDM Fabricated by the PLC-AWG Technology (평판형 AWG 기술을 이용한 광대역 파장다중화/역다중화 소자의 제작 및 특성)

  • Moon, H.M.;Kwak, S.C.;Hong, J.Y.;Lee, K.H.;Kim, D.H.;Kim, J.J.;Choi, S.Y.;Lee, J.G.;Lee, J.H.;Lim, K.G.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.3
    • /
    • pp.185-189
    • /
    • 2007
  • A novel technology for CWDM (Coarse Wavelength Division Multiplexer) utilizing a PLC (Planar Lightwave Circuit)-AWG (Arrayed Waveguide Grating) fabrication process is proposed. BPM (Beam Propagation Method) Simulation results on the employed parabolic-horn-type input slab waveguide of AWG and the performance of the 20 nm-channel spacing CWDM with flattened passband are presented. Waveguides of $0.75{\triangle}%$ have been used in this experiment and the insertion loss at the peak wavelength is 3.5 dB for a Gaussian spectrum and is 4.8 dB for a flat-top spectrum. The bandwidth at 3 dB is better than 10 nm and 13 nm for Gaussian and flat-top spectra, respectively.

Observation of Muscle Activity and Muscle Fatigue During Isotonic Exercise at a Constant Face Using Metronome (메트로놈을 사용한 일정한 페이스의 등장성 운동시 근활성도 및 근육 피로도 관찰)

  • Jun won Choi;Chang hyun Song;Jong min Kim;Woon Mo Jung;Won Gyeong Kim;Han Sung Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.284-292
    • /
    • 2023
  • This study attempted to observe muscle activity and muscle fatigue among isotonic exercise of Biceps Brachii and Deltoidus Medius, which correspond to upper limb muscles, using metronome. For the experiment, 13 adult men participated to evaluate biosignals (ECG, EMG). For quantitative evaluation, 1RM and MVIC test were carried out and a constant pace isotonic excise session was conducted. Five sets of exercise were performed, and each set proceeded to the failure point while the speed condition (30bpm) was assigned. As a result of the experiment, muscle activity in both muscles was significantly reduced in fifth set compared to first set. Muscle fatigue has been confirmed to occur at a significant level within the set, but there was only a significant difference in both muscles in the first and second sets between sets. This is similar to the results of previous studies that gives the same rest time(2min), but further research is needed to see if the conditions for the number of repetitions are affected. Based on the recent increase of interest in muscle strength exercise, this study was conducted to observe the results by varying the conditions of common exercise.

Effect of human biosignal according as foot was heating with hot water (발 부분 온수 열자극시 인체 현상에 미치는 영향)

  • Lee, Woo-Cheol;Min, Kyeug-Kee;SaKong, Sug-Chin
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.5-15
    • /
    • 2006
  • In this paper, we measured the biosignal using hot-water system(STYX ford202) on foot. The biosignal transition data is observed from hot-water thermotherapy on foot. pre and post demonstration conditions under 43$^{\circ}C$ and 45$^{\circ}C$ are checked about 9 physiological factors for 10 persons and 10 days. (Checking Time: pre-test, post-test(5, 10, 15, 20 minutes)). The biosignal transition of demonstration's results showed as belows; Forehead Temperature($^{\circ}C$): -0.69 $\pm$ 0.01 dec, Leg Temperature($^{\circ}C$): 1.51 $\pm$ 0.22 inc, Blood Flow($m\ell/min$): 1.18 $\pm$ 0.50 inc, Blood Pressure(mmHg): (max) -1.49$\pm$ 2.81, (min) -0.06 $\pm$ 0.13 dec, Heart Rate(bpm): 6.97 $\pm$ 0.72 inc, Blood Sugar($mg/d\ell$) : -2.41 $\pm$ 1.55 dec, Oxygen Saturation(%): 1.34 $\pm$ 0.28 inc, Body Fat(%) -1.75 $\pm$ 0.15 dec, Weight(kg): -0.10 $\pm$ 0.04 dec. (dec: decrease, inc: increase)

Wearable Intelligent Systems for E-Health

  • Poon, Carmen C.Y.;Liu, Qing;Gao, Hui;Lin, Wan-Hua;Zhang, Yuan-Ting
    • Journal of Computing Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.246-256
    • /
    • 2011
  • Due to the increasingly aging population, there is a rising demand for assistive living technologies for the elderly to ensure their health and well-being. The elderly are mostly chronic patients who require frequent check-ups of multiple vital signs, some of which (e.g., blood pressure and blood glucose) vary greatly according to the daily activities that the elderly are involved in. Therefore, the development of novel wearable intelligent systems to effectively monitor the vital signs continuously over a 24 hour period is in some cases crucial for understanding the progression of chronic symptoms in the elderly. In this paper, recent development of Wearable Intelligent Systems for e-Health (WISEs) is reviewed, including breakthrough technologies and technical challenges that remain to be solved. A novel application of wearable technologies for transient cardiovascular monitoring during water drinking is also reported. In particular, our latest results found that heart rate increased by 9 bpm (P < 0.001) and pulse transit time was reduced by 5 ms (P < 0.001), indicating a possible rise in blood pressure, during swallowing. In addition to monitoring physiological conditions during daily activities, it is anticipated that WISEs will have a number of other potentially viable applications, including the real-time risk prediction of sudden cardiovascular events and deaths.

A study on the fabrication of Y-branch for optical power distribution and its coupling properties with optical fiber (광분배를 위한 Y-branch 제작과 광파이버와의 결합특성에 관한 연구)

  • 김상덕;박수봉;윤중현;이재규;김종빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3277-3285
    • /
    • 1996
  • In this paper, w designed an opical power distribution device for application to an optical switching and an optical subscriber loop. We fabricated PSG thin film by LPCVD. Based on the measured index of fabricted thin film, rib-type waveguide was transformed to two-dimension by the effective index method and we simulated dispersion property to find asingle-mode condition. We found that the optimum design parameters of rib-type waveguide are:cladding layer of 3.mu.m, core layer of 3.mu.m, buffer layer of 10.mu.m, and core width of 4.mu.m. Each side of the guiding region was etched down to 4.mu.m to shape the core. We used these optimum parameters of the rib-type waveguide with branching angle of 0.5.deg. and simulted the Y-branch waveguide by the BPM simulation. Numerical loss in branching area was claculated to be 0.1581dB and equal to the total loss of the Y-branch. The loss of the fabricated Y-branch waveguide on PSG film ws 1.6dB at .lambda.=1.3.mu.m before annealing but was 1.2dB after annealing at 1000.deg. C for 10 minutes. Consequently, the loss of branching area from 3000.mu.m to 6000.mu.m in the z-direction was 0.8dB, and single-mode propagation was confirmed by measuring the near field pattern. For coupling the fabricated Y-branch waveguide with an optical fiber, we fabricated V-groove which was used as the upholder of optical fiber. An etching angle was 54.deg. and the width and depth of guiding groove was 150.mu.m, 70.mu.m, respectively. The optical fiber is inserted onto V-groove. Both the Y-branch and V-groove were connected through the index matching oil. Coupling loss after connecting Y-branch and the optical fiber on V-groove was 0.34dB and that after injecting index mateching oil was 0.14dB.

  • PDF

Prediction of 305 Days Milk Production from Early Records in Dairy Cattle Using an Empirical Bayes Method

  • Pereira, J.A.C.;Suzuki, M.;Hagiya, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.11
    • /
    • pp.1511-1515
    • /
    • 2001
  • A prediction of 305 d milk production from early records using an empirical Bayes method (EBM) was performed. The EBM was compared with the best predicted estimation (BPE), test interval method (TIM), and the linearized Wood's model (LWM). Daily milk yields were obtained from 606 first lactation Japanese Holstein cows in three herds. From each file of 305 daily records, 10 random test day records with an interval of approximately one month were taken. The accuracies of these methods were compared using the absolute difference (AD) and the standard deviation (SD) of the differences between the actual and the estimated 305 d milk production. The results showed that in the early stage of the lactation, EBM was superior in obtaining the prediction with high accuracy. When all the herds were analyzed jointly, the AD during the first 5 test day records were on average 373, 590, 917 and 1,042 kg for EBM, BPE, TIM, and LWM, respectively. Corresponding SD for EBM, BPE, TIM, and LWM were on average 488, 733, 747 and 1,605 kg. When the herds were analyzed separately, the EBM predictions retained high accuracy. When more information on the actual lactation was added to the prediction, TIM and LWM gradually achieved better accuracies. Finally, in the last period of the lactation, the accuracy of both of the methods exceeded EBM and BPM. The AD for the last 2 samples analyzing all the herds jointly were on average 141, 142, 164, and 214 kg for LWM, TIM, EBM, and BPE, respectively. In the current practices of collecting monthly records, early prediction of future milk production may be more accurate using EBM. Alternatively, if enough information of the actual lactation is accumulated, TIM may obtain better accuracy in the latter stage of lactation.

Gastric Dilatation and Volvulus in Shih-tzu (시츄에서 발견된 위확대염전)

  • Moon, Joon Ho;Kim, Hyun Ah;Ryu, Minok;Jang, Min;Ji, Seoyeon;Lee, Inhyung;Yoon, Junghee;Choi, Mincheol;Youn, Hwayoung;Lee, Byeong Chun;Jang, Goo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.255-258
    • /
    • 2015
  • Gastric dilatation and volvulus (GDV) is an acute and life-threatening disease most commonly affecting large- and giant-breed dogs. However a 17-year-old Shih-tzu (4 kg, spayed female) was hospitalized for acute GDV. Repeated unproductive retching, lethargy, and excessively enlarged abdomen were observed. Physical examination indicated that the patient had suffered from hypothermia ($36.5^{\circ}C$), tachycardia (240 bpm), slowed capillary refill time (> 2 sec.), and pale mucous membrane. Grade III murmur with normal lung sound was auscultated. Abdominal palpation revealed that tympanic regions existed in both the left and right sides. Systolic blood pressure decreased gradually from 220 to 40 mmHg within 4 hours. In blood analysis, slight azotemia was observed by blood urea nitrogen (BUN; 29.1 mg/dl) and creatinine (1.6 mg/dl). Blood lactate concentration (8.13 mmol/l) was severely elevated. Additionally, dilatation and volvulus of the stomach was observed by radiograph. Supportive oxygen, heat, fluid, and drugs were administered with gastric decompressions (e.g., gastrocentesis and nasogastric tube). However the patient entered into comatose status with uncontrollable systolic blood pressure, despite the administration of dobutamine intravenously. The case was closed by euthanasia, considering welfare and age. We finally diagnosed the patient as a GDV, thus this is the first GDV case report in small-breed dog such as Shih-tzu.