Development of An Expert system with Knowledge Learning Capability for Service Restoration of Automated Distribution Substation (고도화된 자동화 변전소의 사고복구 지원을 위한 지식학습능력을 가지는 전문가 시스템의 개발)

  • Ko Yun-Seok;Kang Tae-Gue
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.12
    • /
    • pp.637-644
    • /
    • 2004
  • This paper proposes an expert system with the knowledge learning capability which can enhance the safety and effectiveness of substation operation in the automated substation as well as existing substation by inferring multiple events such as main transformer fault, busbar fault and main transformer work schedule under multiple inference mode and multiple objective mode and by considering totally the switch status and the main transformer operating constraints. Especially inference mode includes the local minimum tree search method and pattern recognition method to enhance the performance of real-time bus reconfiguration strategy. The inference engine of the expert system consists of intuitive inferencing part and logical inferencing part. The intuitive inferencing part offers the control strategy corresponding to the event which is most similar to the real event by searching based on a minimum distance classification method of pattern recognition methods. On the other hand, logical inferencing part makes real-time control strategy using real-time mode(best-first search method) when the intuitive inferencing is failed. Also, it builds up a knowledge base or appends a new knowledge to the knowledge base using pattern learning function. The expert system has main transformer fault, main transformer maintenance work and bus fault processing function. It is implemented as computer language, Visual C++ which has a dynamic programming function for implementing of inference engine and a MFC function for implementing of MMI. Finally, it's accuracy and effectiveness is proved by several event simulation works for a typical substation.

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.

A Study on the Fire Response Scenarios Generation of Unmanned Light Rail Transit with Systems Engineering Architecture Design Methodology (시스템 아키텍처 설계 방법론에 기반한 무인운전 경량전철 차량의 화재대응 시나리오 생성에 관한 연구)

  • Han, Seok-Youn;Kim, Joo-Uk;Kim, Young-min
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.33-43
    • /
    • 2015
  • Modern systems development becomes more and more complicated due to the need on the ever-increasing capability of the systems. In addition to the complexity issue, safety concern is also increasing since the malfunctions of the systems under development may result in the accidents in both the test and evaluation phase and the operation phase. Light rail transit(LRT) with passenger capacity between bus and subway is driven by an unmanned control, so safety issues of LRT in emergency shall be considered more carefully than other rolling stock. Modern railway system is a complex system and many actions in emergency are required. In this view, interoperability approach is effective to identify the related elements in emergency. In this paper, we propose the method to generate the fire response scenario of unmann ed LRT based on the outputs of systems engineering architecture design methodology. The proposed method is could be contributed to establish more reliable and applicable fire response scenario.

Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System (DC 급전시스템의 지락보호계전시스템 개발)

  • Chung Sang-Gi;Jeong Rag-Gyo;Cho Hong-Sik;Lee Ahn-Ho;Kwon Sam-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.427-433
    • /
    • 2005
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot Identify the faulted region which causes long traffic delays and safety problem to passengers. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. One is bus differential protective relay and the other is ground overcurrent protective relay. Both type of relays is similar in principle to the ordinary bus differential protective relay and the ground overcurrent relay used in other power system. In DC traction power supply system, since it is ungrounded, ground fault current is not big enough to operate those relays. To solve the problem, a current control device, called device 'X', is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. Algorithms for these relays are developed and their validity are verified by EMTP simulation.

Implementation of IS-95C Multimedia Terminal using GPS (GPS 연동 IS-95C 멀티미디어 단말기 구현)

  • 하재승
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1133-1138
    • /
    • 2001
  • In this paper, we implemented that MMT(Multimedia Terminal) demonstrates spot news, weather forecast, sports news and cultural news employed CDMA mobile communication networks. The MMT displays mobile pictures/joint pictures/on screen ad and to make known Bus stop or Mobile stations. The MMT gives driver's and passenger's safety and valuable information for one's use GPS satellites. We verified to make real time mobile picture transfer use of CDMA2000 1×(IS-95C) network and development the scheduler control each module. This system tested on vehicle that train and bus. MMT was implemented high reliability and stability by the embedded system. The mobile terminal shows reliable data transfer rate about 74Kbps on IS-95C.

  • PDF

Analysis for Generation of Heat of Cubicle Eddy Current in A Hydroelectric Power Plant (수력발전소 큐비클 와전류에 의한 발열현상 분석)

  • Ok, Yeon-Ho;Lee, Eun-Chun;Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.431-433
    • /
    • 2000
  • The hydroelectric Power plant of the KOWACO have been establishing and operating a full scale electric power facility, doing the largest generation during the flood period of the summer season. When the huge capacity generator is run like the Chung-Ju's hydroelectric Power plant, the generator current per generator flows a great current estimated at 5,900 A. The bus bar of a great current flows in cubicle, owing to the bus bar current Eddy current is created around magnetic substance and a local heating phenomenon occurs due to Joule heat finally. a local heating phenomenon still exists the danger of safety accident due to contact and accompanies losses enough to healing capacity inevitably. this study applies and examines related theory and numerical formula about the heating cause of a great current & enforces technical verification about the method of heating reduction previous managed at the site.

  • PDF

Development of a Critical Value According to Commercial use Vehicle(BUS) (사업용 차량(버스)의 위험운전 임계값 개발)

  • Oh, Ju-Taek;Lee, Sang-Yong;Kim, Young-Sam
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.85-95
    • /
    • 2009
  • According to the accident statistics published by the National Police Agency in 2007, the number of commercial vehicle accidents explains 3.5 percent of the total number of traffic accidents of the year. Compared to other types of vehicles commercial vehicles may provide more serious damages to both driver himself and passengers. Thus, they generate more serious social and economic problems. There have been various forms of systems such as a digital speedometer or a black box to meet the social requirement for reducing traffic accidents and improving safe driving. However, since the current systems are based on the data often accidents happened, there are lots of limitations to control drivers in real-time. Also, the current speedometers provide drivers with only speeds of vehicles and RPM information regardless of actual dangerous drive behaviors. Therefor, they lack of the effectiveness in terms of safety. In this research, real-time information systems for improving driver safety based on automatic risky driving behaviors, and thresholds to determine risky driving patterns were studied.

  • PDF

System of Vehicle Auto Safety Simulation over MOST-CAN Network Gateway (MOST-CAN 네트워크 게이트웨이를 이용한 차량 자동 안전제어 시뮬레이션 시스템 설계 및 구현)

  • Choi, Yong-woo;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.773-776
    • /
    • 2009
  • Last of the car industry can be grouped in one-vehicle electronic equipment, the development of the network, and accordingly the communication between each of the network is important. The network currently being used in vehicles include CAN, LIN, MOST, FlexRay, etc. are used. Network of several different kinds of applications using the federation said they were also germ, which causes the driver some more convenient environment, the desire to drive a vehicle that is increasing. If vehicle for other network environments with one integrated environment to make it a gateway for research done actively, the more applications are expected to be developed. In this paper, using gateway between CAN bus used for Body Train-side control of the vehicle network and MOST provided for infotainment systems. In vehicle automatic safety control system will be designed by One of CAN Nodes car speed information sending to MOST Navigation while don't received GPS information in the tunnel.

  • PDF

RESULTS OF FUNCTIONAL SIMULATION FOR ABS WITH PRE-EXTREME CONTROL

  • IVANOV V.;BELOUS M.;LIAKHAU S.;MIRANOVICH D.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2005
  • The creation of automotive systems of active safety with intelligent functions needs the use of new control principles for the wheel and automobile. One of such directions is the pre-extreme control strategy. Its aim is the ensuring of wheel's work in pre-extreme, stable area of tire grip wheel slip dependence. The simplest realization of pre-extreme control in automotive anti-lock brake systems consists in the threshold and gradient algorithms. A comparative analysis of these algorithms, which has been made on 'hardware in-the-loop' simulation results of the braking for bus with various anti-lock brake systems (ABS), indicated their high efficiency.

Voltage Control and Security Assessment of Power System Using Mixed Integer Linear Programming (혼합정수 선형계획법을 이용한 계통의 전압제어 및 안전도 평가)

  • 김두현;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.70-76
    • /
    • 1999
  • In this paper, a mixed-integer programming approach is presented for adjusting the voltage profiles in a power system. The advent of large-scaled system makes the reactive power and voltage problem-an attempt to achieve an overall improvement of system security, service quality and economy-more complex and seriously, Although the problem is originally a nonlinear optimization problem, it can be formulated as a mixed integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The MILP code is developed by the branch and bound process search for the optimal solution. The variable for modeling transformer tap positions is handled as discrete one, and other variables continuous ones. Numerical data resulting from case study using a modified IEEE 30 bus system with outaged line show that the MILP can produce more reductions of magnitude in the operating cost. The convergence characteristics of the results are also presented and discussed.

  • PDF