• Title/Summary/Keyword: buried pipeline

Search Result 219, Processing Time 0.025 seconds

The Development and Introduction of External Corrosion Direct Assessment Measures for Urban Gas Pipelines (외면부식 직접평가법 개발 및 국내 도입 연구)

  • Ryou, Young-Don;Lee, Jin-Han;Yoon, Yung-Ki;Lim, Ho-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.12-19
    • /
    • 2014
  • To minimize the risk of corrosion on buried pipeline and to maximize the efficiency of cathodic protection, various indirect inspection techniques have been used for decades. In the United States, 49 CFR has regulated the external corrosion direct assessment for buried pipelines. In Korea, there is no provision for external corrosion direct assessment but there is only, according to the KGS Code, provision that if the survey of the defects of buried pipeline and the leakage test for the pipe were conducted, it is deemed to leakage inspection. We, therefore, have suggested external corrosion direct assessment method appropriate to domestic status through the survey of the regulations and standards of UK and the USA and the investigation of domestic situation on coating damage detection method. The proposed external corrosion direct evaluation method was used as the basis when introducing the precision safety diagnosis regulation for the medium-pressure pipe in Korea.

Standards of Distance between Gas Pipeline and Tower Ground (가스배관과 철탑접지의 이격거리 관련 기준)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.18-22
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we investigated the arcing phenomena through soil between a power line tower and a pipeline and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

Experimental Study of Load Characteristics of Buried and Exposed Large-Diameter Pipelines Using Fiber-Optic Strain Sensor

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.194-201
    • /
    • 2020
  • In this study, an optical-fiber sensor was used to measure loads that could act in an environment similar to the loading conditions that exist in an actual pipe. The structure and the installation method of the optical-fiber strain sensor were applied considering the actual large pipe and the buried pipe environment. Load tests were performed using a displacement sensor and sandbags to determine the deflection of the pipe according to the external load, and the linear measurement results were verified. Considering the conditions that could exist in the actual pipe, the test method was presented, and the strain of the buried pipe generated at this time was measured.

Simplified modelling of continous buried pipelines subject to earthquake fault rupture

  • Paolucci, Roberto;Griffini, Stefano;Mariani, Stefano
    • Earthquakes and Structures
    • /
    • v.1 no.3
    • /
    • pp.253-267
    • /
    • 2010
  • A novel simple approach is presented for the seismic analysis of continuous buried pipelines subject to fault ruptures. The method is based on the minimization of the total dissipated energy during faulting, taking into account the basic factors that affect the problem, namely: a) the pipe yielding under axial and bending load, through the formation of plastic hinges and axial slip; b) the longitudinal friction across the pipe-soil interface; c) the lateral resistance of soil. The advantages and drawbacks of the proposed method are highlighted through a comparison with previous approaches, as well as with finite element calculations accounting for the 3D kinematics of the pipe-soil-fault systems under large deformations. Parametric analyses are also provided to assess the relative influence of the various parameters affecting the problem.

Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline (천연가스 공급배관의 사용적합성 통합프로그램)

  • Kim, Woo-Sik;Kim, Young-Pyo;Kim, Cheol-Man;Baek, Jong-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

Standards of Distance between Gas Pipeline and Tower Ground (가스배관과 철탑접지의 이격거리 관련 기준)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • 한국가스학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.191-195
    • /
    • 2006
  • Because of the continuous growth of energy consumption and also the tendency to site gas pipeline and power line along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. The lightning strokes collected by an electric substation or power line tower might cause arcing through the soil to an adjacent gas pipeline. This paper gives the outline of the resistance coupling and the standards of distance between gas pipeline and tower ground.

  • PDF

Acoustic Wave Propagation Characteristics Corresponding to the Cut-off Frequency in Gas Pipeline (가스 배관의 차단 주파수에 따른 음파전달특성 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.693-700
    • /
    • 2008
  • High-Pressure gas Pipeline which is buried in underground has the Possibility that will be exposed to unexpected dangerous impact of construction equipment. To protect from this kind of danger, the real-time health monitoring system of the high-pressure gas pipeline is necessary. First of all, to make the real-time health monitoring system clearly, the acoustic wave propagation characteristics which are made from various construction equipment impacts must be identified. In link of technical development that prevents the damage of high-pressure gas pipeline, this paper gives FEM(finite element method) and BEM(boundary element method) solutions to identify the acoustic wave propagation characteristic of the various impact input signals which consist of Direc delta function and convolution signal of 45 Hz square signal and random signal.