• 제목/요약/키워드: built-in storage battery

검색결과 22건 처리시간 0.02초

배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가 (Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage)

  • 김현준;김도현;김경태;한병문
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

Grid-tied Power Converter for Battery Energy Storage Composed of 2-stage DC-DC Converter

  • Kim, Do-Hyun;Lee, Yoon-Seok;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1400-1408
    • /
    • 2013
  • This paper proposes a new grid-tied power converter for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

Analysis, Design and Implementation of Flexible Interlaced Converter for Lithium Battery Active Balancing in Electric Vehicles

  • Dai, Shuailong;Wang, Jiayu;Li, Teng;Shan, Zhifei;Wei, Yewen
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.858-868
    • /
    • 2019
  • With the widespread use of modern clean energy, lithium-ion batteries have become essential as a more reliable energy storage component in the energy Internet. However, due to the difference in monomers, some of the battery over-charge or over-discharge in battery packs restrict their use. Therefore, a novel multiphase interleaved converter for reducing the inconsistencies of the individual cells in a battery pack is proposed in this paper. Based on the multiphase converter branches connected to each lithium battery, this circuit realizes energy transferred from any cell(s) to any other cell(s) complementarily. This flexible interlaced converter is composed of an improved bi-directional Buck-Boost circuit that is presented with its own available control method. A simulation model based on the PNGV model of fundamental equalization is built with four cells in PSIM. Simulation and experimental results demonstrate that converter and its control achieve simple and fast equalization. Furthermore, a comparison of traditional methods and the HNFABC equalization is provided to show the performance of the converter and the control of lithium-based battery stacks.

2단 DC-DC 컨버터로 구성된 배터리 에너지저장용 계통연계형 전력변환장치 (Grid-tied Power Conditioning System for Battery Energy Storage Composed of 2-stage DC-DC converter)

  • 박아련;김도현;김경태;한병문;이준영
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1848-1856
    • /
    • 2012
  • This paper proposes a new grid-tied power conditioning system for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through theoretical analysis and computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

소형화된 듀얼 주파수 FM 송신기 개발 (Development of miniaturized dual-frequency FM transmitter)

  • 류정탁
    • 한국산업정보학회논문지
    • /
    • 제16권5호
    • /
    • pp.31-35
    • /
    • 2011
  • 본 논문에서는 소형화된 듀얼 주파수 FM 송신기의 개발과 현장에서의 실험 결과를 보여주고 있다. 개발된 시스템의 크기는 2.6 cm ${\times}$ 2.6 cm ${\times}$ 2.6 cm 이다. 사용주파수는 88.1 MHz 과 88.3 MHz를 사용하였다. 시스템의 동작 전원은 3.7 V로 전원 공급은 한번 충전에 7시간 사용할 수 있는 내장 밧데리를 사용하였다. 전송 주파수의 채널 분리도는 40dB이다. 현장에서의 실험 결과 3m 이내의 공간에서 전파 특성이 안정적이며 이는 개발 제품이 원하는 사용 범위에 속한다.

에너지 자립섬 EMS 어플리케이션의 기능적 특성 (Functional Properties of Stand-alone Microgrid EMS Application)

  • 이하림;전영환;채우규;박중성
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.115-119
    • /
    • 2016
  • For many past years, research in the operation of stand-alone Microgrid, which provides electric power generated from renewable energy sources and energy storage system instead of diesel generators, has been a major issue in order to prepare the exhaustion of fossil fuel and to protect environment, in island grids. Samso Island, known as the world's first stand-alone Microgrid in Denmark, is connected to the mainland grid through AC system, which has different technical conditions with Korea's isolated power system. Korea's first stand-alone Microgrid has been built in Ga-sa island, Chun-la-nam-do, based on Energy Management System (EMS) operation, and other islands are under construction to follow the next step. These stand-alone Microgrid's has large capacity of Battery Energy Storage System (BESS) and the proportion of the renewable energy sources are large, which makes it necessary to use a Microgrid-Energy Management System (MG-EMS) to operate the grid effectively and economically. However, since the main subject of MG-EMS is different from EMS, specific characteristics and functions must be different as well. In this paper, the necessary characteristics and functions are explained for a general MG-EMS compared to a large power system EMS.

하드웨어 시뮬레이터에 의한 양극형 직류배전시스템의 동작특성 분석 (Operational Characteristic Analysis of Bipolar DC Distribution System using Hardware Simulator)

  • 이진규;이윤석;김재혁;한병문
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.476-483
    • /
    • 2014
  • This paper describes the operational analysis results of the bipolar DC distribution system coupled with the distributed generators. The energy management for AC/DC power trade and the operational principle of distributed generators and energy storages were first analyzed by computer simulation with PSCAD/EMTDC software. After then a hardware simulator for the bipolar DC distribution system was built, which is composed of the grid-tied three-level inverter, battery storage, super-capacitor storage, and the voltage balancer. Various experiments with the hardware simulator were carried out to verify the operation of bipolar DC distribution system. The developed simulator has an upper-level controller which operates in connection with the controllers for each distributed generator and the battery energy storage based on CAN communication. The developed hardware simulator are possible to use in designing the bipolar DC distribution system and analyzing its performance experimentally.

Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구 (A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed)

  • 이상우;강진규;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

공동주택 발코니 PV 연계 가정용 BESS의 에너지 절감 효과 분석 (Analysis of Energy Saving Effect of the Residential BESS Connected to the Balcony-PV in Apartment Houses)

  • 김차년;엄지영;김용기
    • 한국태양에너지학회 논문집
    • /
    • 제40권3호
    • /
    • pp.21-31
    • /
    • 2020
  • The government mandates gradually zero energy building and Photovoltaic power generation systems installed in buildings are emerging as the most realistic alternative to increase the independence rate of building energy. In this study, we propose a method to reduce the power consumption of households by increasing the PV capacity of balconies and applying the method used the charged electric power stored in batteries after sunset. In order to evaluate the electric power energy savings of the residential BESS, a balcony PV 1.2 kW and a battery pack 2 kWh were installed for 9 houses in 4 apartments in Seoul and Gyeonggi-do. The BESS is charged when the balcony PV is generated electric power, and when solar power generation is finished, it supplies power to the electric appliances connected to the load. As a result of installing the solar PV module 1.2 kW and 2 kWh class BESS for 3 households located in Seoul and Gyeonggi-do, the average electric power consumption saving rate was 40%. The reduction in electricity consumption in the case of zero generation surplus power by maximizing the utilization rate of BESS has been improved to about 53%. Therefore, in order to increase the self-sufficiency rate of electric energy in apartment houses, it is effective to increase the solar photovoltaic capacity of the balcony and apply the residential BESS. In the future, it is believed that the balcony PV and home BESS will play a key role in achieving mandatory zero-energy housing.

DC 마이크로그리드의 동작분석을 위한 하드웨어 시뮬레이터 개발 (Development of Hardware Simulator for Operation Analysis of DC Microgrid)

  • 이지헌;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.251-252
    • /
    • 2011
  • This paper describes the development of hardware simulator for the operation analysis of DC microgrid, which has a wind power, solar power and fuel cell as a distributed generation, and a supercapacitor and battery as an energy storage. A detailed simulation model for the DC microgrid was developed for operation analysis. Based on simulation results a hardware simulator was built in the lab for the purpose of operation analysis. The developed hardware simulator can be utilized to evaluate with practical manner the performance of actual microgrid in the field.

  • PDF