• 제목/요약/키워드: building rooftop

Search Result 128, Processing Time 2.24 seconds

필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로- (A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire-)

  • 황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

울산 주상복합건물 현장조사를 통한 화재사례 분석 (Analysis of fires case through on-field survey of residential and commercial building in Ulsan)

  • 조휘제;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.84-85
    • /
    • 2021
  • The fire that broke out in a residential and commercial complex in Ulsan in October 2020 was large, but no deaths occurred. For this reason, there was a difference from the previous cases, so it was analyzed through field survey. The fire was expanded to the entire building by aluminum composite panels constructed by external heat method and SMC panels in evacuation safety zones, and fire was expanded to nearby mart due to wind on the day of the fire, and there were many evacuation spaces such as 15th, 28th, and rooftop heliports.

  • PDF

일본의 건축물 녹화 관련제도 연구 (A Study on Related System of Building Greening in Japan)

  • 윤용한;주진희;김원태
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1397-1402
    • /
    • 2010
  • In recently, building greening to improve the urban environment is a very important areas. Thus, in order to promote the building greening is needed for the arrangement of its related system. In this study, analyzed the related system in Japan and the results obtained are as follows. Related system in Japan are to promote the spread of compulsory and dissemination of guidance. And to promote the spread of dissemination of guidance are to allowed a system to be included in green area of the site required, plans to loan the costs of greening, plans to subsidize the cost of greening, tax reduction and exemption, incentive on floor area ratio, plant supply and other technical guidance system. In conclusion, in order to promote the building greening note the related system of Japan and our related system should be arranged.

옥상 무근콘크리트 복합열화 방지를 위한 시공 프로세스 구축 및 배합 설계에 관한 연구 (A study of Building Mix-Design and Construction Process to Reduce the Combined Deterioration of Plain Concrete.)

  • 김대건;이우근;강예진;여동규;김도훈;이동운
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2018
  • In the case where the building's rooftop was laid without any foundation, the combined deterioration, such as the repetition of shrinkage and expansion caused by temperature changes, caused further cost generation and damage. To prevent this, the concrete mixing design and construction process shall be established to resist combined deterioration.

  • PDF

옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발 (Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse)

  • 조정화;이인복;이상연;김준규;크리스티나;최영배;이민형;정효혁;정득영
    • 생물환경조절학회지
    • /
    • 제31권3호
    • /
    • pp.246-254
    • /
    • 2022
  • 본 연구는 급속하게 성장하는 시설농업과 동시에 증가하는 에너지 사용량 및 탄소배출량을 저감하기 위해, 온실의 에너지 부하를 동적으로 분석하기 위한 작물에너지의 다중 회귀모델 개발을 수행하였다. 온실은 연중 안정적인 대량 생산을 위한 적절한 환경을 조성하기 위해 에너지 투입이 필요하다. 도시농업의 일종인 옥상온실 플랫폼을 통해 건물에서 버려지거나 활용되지 않는 에너지를 옥상온실에서 사용할 수 있다. 옥상온실의 효율적인 운영을 위해서는 다양한 환경 조건에 대한 동적 에너지 분석이 선행되어야 하며, 온실에 도입되는 태양 에너지의 40-75%가 작물을 위한 에너지 교환이므로 필수적으로 고려되어야 한다. 한국기계연구원 내 옥상온실에서 여름철에 청경채를 재배하며 생장단계에 따른 에너지 교환을 분석하였다. 작물을 중심으로 미기상 및 양액 환경 분석과 생장 특성 조사를 수행하였다. 정식일수에 따른 엽면적지수를 추정하였으며, 개발된 수식은 결정계수 0.99로 분석되었다. 또한 작물에너지 흐름에 지배적인 잎 표면온도로부터의 현열부하와 증발산에 의한 잠열부하로 나누어 모델을 개발하였다. 엽온과 증발산량을 각각 다중 회귀모델을 이용하여 추정하고 실측한 값을 비교해 보았을 때, 평균 결정계수 0.95, 0.71로 분석되었으며, 이 모델을 이용하여 옥상온실의 에너지 부하를 동적으로 산정하기 위한 모델에 입력값으로 사용할 수 있을 것으로 판단된다.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 - (Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.86-94
    • /
    • 2018
  • 제천 스포츠센터 화재로 29명이 사망하고 40명이 부상을 입었다. 이 논문에서는 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 요인을 분석하기 위해 저자의 화재조사 결과를 토대로 건물과 설비의 구조적인 요인을 분석하고 있다. 건물과 설비의 구조적인 요인은 필로티 구조의 주차장, 필로티 주차장과 로비 사이 방화구획 미비, 필로티 주차장에 스프링클러설비 미설치, 1층 주계단에 방화문 미설치, 옥상에 소화수조 미설치, 2층 주출입구에 벽체 매립형 방화문 설치, EPS실 및 배관 피트 층별 방화구획 부실, 배수배관 연결부의 누수, 화물용 승강기의 승강로와 실내에 면하는 벽체에 합판 설치, 폐쇄형 옥상구조로 개조, 주차장 반자 안쪽 천장에 스티로폼 단열재 부착, 2층 여탕 무창층 강화유리 구조, 드라이비트 외벽으로 분석하였다.

Types of Vertical Smart Farms and Awareness of their use in Korean Cities Types and Feasibility Analysis of Vertical Smart Farms in Korean Cities

  • Heo, Han Kyul;Lee, Eunseok
    • 인간식물환경학회지
    • /
    • 제24권3호
    • /
    • pp.257-266
    • /
    • 2021
  • Background and objective: Vertical smart farm (VSF) is an alternative that contributes to solving various problems such as climate change and food shortage. This study focused on the types and awareness of VSF to introduce and diffuse VSF. We aimed to investigate the types of VSF and citizens' awareness on VSF. We analyzed 1) where the smart farm technology could be implemented on a building; 2) what citizens think about VSF; and 3) suggested what is most necessary for the introduction and diffusion of VSF in the future based on citizens' perception. Methods: VSF types were investigated through case studies on VSF in Korea and overseas. Citizens' perception on VSF was investigated through a questionnaire survey. A statistical analysis was conducted with the survey results for implications of the introduction and diffusion of VSF. Results: Four types of VSF were derived: rooftop farms, facade farms, indoor farms, and farms using the whole building. The survey showed that 29.2%, 27.8%, and 22.2% of respondents knew well about urban agriculture, smart farms, and vertical smart farms, respectively. Respondents answered that improving awareness is the most important factor to introduce VSF. According to the statistical analysis, it was determined that education and promotion of the necessity of VSF would be important to diffuse the VSF. Conclusion: VSF can be a solution to a variety of problems we face. The results of this study suggest a direction for the introduction and diffusion of VSF. In order to introduce VSF in the future, additional studies must be conducted on the legal system.

학교 건축에 대한 BIPV시스템의 성능 평가 (Performance Evaluation of BIPV Systems Applied in School Buildings)

  • 박경은;김진희;김준태
    • 교육시설
    • /
    • 제11권5호
    • /
    • pp.14-23
    • /
    • 2004
  • Building-integrated photovoltaic(BIPV) systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Besides of these benefits, the application of PV systems into school buildings tends to play an important role in energy education to students. In this context, this study aims to analyse the applicability of PV systems into school buildings. For an existing school building, four types of BIPV designs were developed; rooftops, wall-attached, wall-mounted with angle, and sunshading device. Based on energy modeling of those BIPV systems, the whole 60.1kWp rated PV installation is expected to yield about 65.6MWh of electricity, that is about 50% more than the annual electricity consumption of the school, 44MWh. It was also found that the applicability of the PV systems into the school building was very high, and the rooftop systems with the optimized angle was the most efficient in energy production, followed by sunshading, wall-mounted with angle and wall-attached. It concludes that school buildings have a reasonable potential to apply PV systems in the aspects of building elements and electricity production.

수원시 소재의 한 대학 내 환경방사선량 측정 분석 (Analysis of the Environmental Radiation Dose Measured at the University Located in Suwon City)

  • 이인자;정유진;김청경;김희솔;윤현민;박다정;고요한
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.233-238
    • /
    • 2014
  • 경기도 수원시에 있는 한 대학의 두 건물(오래된 건물과 새 건물)의 실내외(지하, 옥상)에서 2013년 4월 첫 주부터~ 2014년 3월 말 주 까지 1년간 1주일에 2회씩 환경방사선량을 측정한 결과 다음과 같은 결론을 얻었다. 1. 두 건물의 환경방사선량은 $0.169727{\mu}Sv/hr$이었고, 가장 작게 측정된 값은 $0.076{\mu}Sv/hr$이었고, 가장 높게 측정된 값은 $0.300{\mu}Sv/hr$이었다. 2. 오래된 건물의 환경방사선량이 $0.176374{\mu}Sv/hr$, 새 건물이 $0.163053{\mu}Sv/hr$로 오래된 건물에서 더 높게 측정되었다. 3. 1년 중 가장 낮게 환경방사선량이 측정된 달은 11월로 평균 $0.152844{\mu}Sv/hr$이고, 가장 높게 측정 된 달은 5월로 평균 $0.197222{\mu}Sv/hr$이다. 4. 측정 장소 비교에서 실내의 환경방사선량은 $0.164649{\mu}Sv/hr$, 실외는 $0.174779{\mu}Sv/hr$로 실외에서 높게 측정되었다. 5. 계절별로 가장 낮게 측정된 환경방사선량은 겨울로 $0.157788{\mu}Sv/hr$이고, 가장 높게 측정된 계절은 봄 $0.183846{\mu}Sv/hr$이며, 봄, 여름, 가을, 겨울 순으로 적게 측정되었다.

외기조건이 개질된 라텍스 혼입콘크리트 슬래브 표면에 미치는 영향 (Effects of climate condition on concrete slab with modified-latex)

  • 차훈;김대건;최상환;문경식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.7-8
    • /
    • 2014
  • Latex-modified concrete using ready mix concrete (R-LMC) was developed for application of building construction project (specifically, the rooftop of a parking garage unable to use heavy equipments for bridge deck overlay) due to three major outstanding properties of R-LMC; bond strength, resistance of cracks at early age, and resistance of freezing and thawing. However, R-LMC at the placement stage is required to be sufficiently cured because R-LMC is very sensitive to rate of evaporation of surface moisture. This study focused on effects of different curing methods and climate condition on cracks on the surface of hardened R-LMC considering the chart of rate of evaporation of surface moisture from concrete provided by American Concrete Institute in manual for placement of latex modified concrete.

  • PDF