• Title/Summary/Keyword: building loads

Search Result 953, Processing Time 0.023 seconds

Evaluation of thermal comfort and cooling loads for a multistory building

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.1
    • /
    • pp.65-77
    • /
    • 2017
  • The latest UK Climate Projections (UKCP09) show that mean daily temperatures will increase everywhere in the United Kingdom. This will significantly affect the thermal and energy performance of the current building stock. This study examines an institutional fully glazed building and looks into the changes in the cooling loads and thermal comfort of the occupants during the occupied hours of the non-heating period. Furthermore, it investigates the effect of relative humidity (RH) on thermal comfort. The Design Summer Year (DSY) 2003 for London Heathrow has been used as a baseline for this study and the DSY 2050s High Emissions scenario was used to examine the performance of the building under future weather conditions. Results show a 21% increase of the cooling loads between the two examined scenarios. Thermal comfort appears to be slightly improved during the months of May and September and marginally worsen during the summer months. Results of the simulation show that a relative humidity control at 40% can improve the thermal comfort for 53% of the occupied hours. A comparison of the thermal comfort performance during the hottest week of the year, shows that when the relative humidity control is applied thermal comfort performance of the 2050s is similar or better compared to the thermal comfort performance under the baseline.

High-frequency force balance technique for tall buildings: a critical review and some new insights

  • Chen, Xinzhong;Kwon, Dae-Kun;Kareem, Ahsan
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.391-422
    • /
    • 2014
  • The high frequency force balance (HFFB) technique provides convenient measurements of integrated forces on rigid building models in terms of base bending moments and torque and/or base shear forces. These base moments or forces are then used to approximately estimate the generalized forces of building fundamental modes with mode shape corrections. This paper presents an analysis framework for coupled dynamic response of tall buildings with HFFB technique. The empirical mode shape corrections for generalized forces with coupled mode shapes are validated using measurements of synchronous pressures on a square building surface from a wind tunnel. An alternative approach for estimating the mean and background response components directly using HFFB measurements without mode shape corrections is introduced with a discussion on higher mode contributions. The uncertainty in the mode shape corrections and its influence on predicted responses of buildings with both uncoupled and coupled modal shapes are examined. Furthermore, this paper presents a comparison of aerodynamic base moment spectra with available data sets for various tall building configurations. Finally, e-technology aspects in conjunction with HFFB technique such as web-based on-line analysis framework for buildings with uncoupled mode shapes used in NALD (NatHaz Aerodynamic Loads Database) is discussed, which facilitates the use of HFFB data for preliminary design stages of tall buildings subject to wind loads.

Across-wind excitation mechanism for interference of twin tall buildings in tandem arrangement

  • Zu, G.B.;Lam, K.M.
    • Wind and Structures
    • /
    • v.26 no.6
    • /
    • pp.397-413
    • /
    • 2018
  • Excitation mechanism of interference effect between two tall buildings is investigated with wind tunnel experiments. Synchronized building surface pressure and flow field measurements by particle image velocimetry (PIV) are conducted to explore the relationship between the disturbed wind flow field and the consequent wind load modification for twin buildings in tandem. This reveals evident excitation mechanisms for the fluctuating across-wind loads on the buildings. For small distance (X/D < 3) between two buildings, the disturbed flow pattern of impaired vortex shedding is observed and the fluctuating across-wind load on the downstream building decreases. For larger distance ($X/D{\geq}3$), strong correlation between the across-wind load of the downstream building and the oscillation of the wake of the upstream building is found. By further analysis with conditional sampling and phase-averaged techniques, the coherent flow structures in the building gap are clearly observed and the wake oscillation of the upstream building is confirmed to be the reason of the magnified across-wind force on the downstream building. For efficient PIV measurement, the experiments use a square-section high-rise building model with geometry scale smaller than the usual value. Interference factors for all three components of wind loads on the building models being surrounded by another identical building with various configurations are measured and compared with those from previous studies made at large geometry scale. The results support that for interference effect between buildings with sharp corners, the length scale effect plays a minor role provided that the minimum Reynolds number requirement is met.

Evaluation of mode-shape linearization for HFBB analysis of real tall buildings

  • Tse, K.T.;Yu, X.J.;Hitchcock, P.A.
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.423-441
    • /
    • 2014
  • The high frequency base balance (HFBB) technique is a convenient and relatively fast wind tunnel testing technique for predicting wind-induced forces for tall building design. While modern tall building design has seen a number architecturally remarkable buildings constructed recently, the characteristics of those buildings are significantly different to those that were common when the HFBB technique was originally developed. In particular, the prediction of generalized forces for buildings with 3-dimensional mode shapes has a number of inherent uncertainties and challenges that need to be overcome to accurately predict building loads and responses. As an alternative to the more conventional application of general mode shape correction factors, an analysis methodology, referred to as the linear-mode-shape (LMS) method, has been recently developed to allow better estimates of the generalized forces by establishing a new set of centers at which the translational mode shapes are linear. The LMS method was initially evaluated and compared with the methods using mode shape correction factors for a rectangular building, which was wind tunnel tested in isolation in an open terrain for five incident wind angles at $22.5^{\circ}$ increments from $0^{\circ}$ to $90^{\circ}$. The results demonstrated that the LMS method provides more accurate predictions of the wind-induced loads and building responses than the application of mode shape correction factors. The LMS method was subsequently applied to a tall building project in Hong Kong. The building considered in the current study is located in a heavily developed business district and surrounded by tall buildings and mixed terrain. The HFBB results validated the versatility of the LMS method for the structural design of an actual tall building subjected to the varied wind characteristics caused by the surroundings. In comparison, the application of mode shape correction factors in the HFBB analysis did not directly take into account the influence of the site specific characteristics on the actual wind loads, hence their estimates of the building responses have a higher variability.

Will CFD ever Replace Wind Tunnels for Building Wind Simulations?

  • Phillips, Duncan A.;Soligo, Michael J.
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.2
    • /
    • pp.107-116
    • /
    • 2019
  • The use of computational fluid dynamics (CFD) is becoming an increasingly popular means to model wind flows in and around buildings. The first published application of CFD to both indoor and outdoor building airflows was in the 1970's. Since then, CFD usage has expanded to include different aspects of building design. Wind tunnel testing (WTT) on buildings for wind loads goes back as far as 1908. Gustave Eiffel built a pair of wind tunnels in 1908 and 1912. Using these he published wind loads on an aircraft hangar in 1919 as cited in Hoerner (1965 - page 74). The second of these wind tunnels is still in use today for tests including building design ($Damljanovi{\acute{c}}$, 2012). The Empire State Building was tested in 1933 in smooth flow - see Baskaran (1993). The World Trade Center Twin Towers in New York City were wind tunnel tested in the mid-sixties for both wind loads, at Colorado State University (CSU) and the [US] National Physical Laboratory (NPL), as well as pedestrian level winds (PLW) at the University of Western Ontario (UWO) - Baskaran (1993). Since then, the understanding of the planetary boundary layer, recognition of the structures of turbulent wakes, instrumentation, methodologies and analysis have been continuously refined. There is a drive to replace WTT with computational methods, with the rationale that CFD is quicker, less expensive and gives more information and control to the architects. However, there is little information available to building owners and architects on the limitations of CFD for flows around buildings and communities. Hence building owners, developers, engineers and architects are not aware of the risks they incur by using CFD for different studies, traditionally conducted using wind tunnels. This paper will explain what needs to happen for CFD to replace wind tunnels. Ultimately, we anticipate the reader will come to the same conclusion that we have drawn: both WTT and CFD will continue to play important roles in building and infrastructure design. The most pressing challenge for the design and engineering community is to understand the strengths and limitations of each tool so that they can leverage and exploit the benefits that each offers while adhering to our moral and professional obligation to hold paramount the safety, health, and welfare of the public.

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

Dynamic Analysis for Base Isolated Structure with Shear Keys (쉬어키를 가진 면진건축물의 동적해석)

  • Han, Duck-Jeon;Kim, Tae-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.1 s.23
    • /
    • pp.45-53
    • /
    • 2007
  • Recently, high-rise base isolated building structures with shear keys are often constructed in Japan which frequently occurs earthquakes. High-rise buildings are less damaged because those buildings have longer natural period than md or low rise buildings. The shear key is device that prevents the base isolators operating by the wind loads not by the earthquake loads. In case of big base shear force acts on the shear keys by earthquake, this device is broken and base isolator is operated. Therefore, seismic intensities play a role in acting on the shear keys. If wind loads are hither than the earthquake loads, the shear keys designed by wind loads are not operated in earthquakes. So, the requirements of shear keys in high-rise base isolated building structures must be examined in Korea with moderate seismic legions. In this study shear keys are applied with 5 and 15 stories base isolated building structures and investigated their dynamic responses to original and 1/2 scale downed El Centre NS(1940) ground motions. The results show that the yield shear forces of the shear keys affect significantly the dynamic behavior of base isolated building structures

  • PDF

Wind Load Evaluation of Tall Building Using Kalman Filter (칼만 필터를 이용한 고층건물의 풍하중산정 기법에 관한 연구)

  • Hwang Jae-Seung;Kim Hong-Jin;Choi Rak-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.688-695
    • /
    • 2005
  • The aim of this study is to develop a procedure to estimate the wind loads from the accelerations of a tall building structure. The wind loads may be directly calculated using the inverse analysis or simply integrating the wind pressures of the overall structure. But, these methods are too expensive and impossible to implement in some cases. In this study, a simple method is proposed to estimate the wind loads using the Kalman filter. This method is very stable compared to the direct integration of the acceleration to get the velocity or displacement. The proposed method is verified thorough numerical analysis, and results show that the proposed method is robust and estimates the wind loads accurately.

  • PDF

Behaviour of Multi-Storey Prefabricated Modular Buildings under seismic loads

  • Gunawardena, Tharaka;Ngo, Tuan;Mendis, Priyan
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1061-1076
    • /
    • 2016
  • Prefabricated Modular Buildings are increasingly becoming popular in the construction industry as a method to achieve financially economical buildings in a very short construction time. This increasing demand for modular construction has expanded into multi-storey applications where the effect of lateral loads such as seismic loads becomes critical. However, there is a lack of detailed scientific research that has explored the behaviour of modular buildings and their connection systems against seismic loads. This paper will therefore present the nonlinear time history analysis of a multi-storey modular building against several ground motion records. The critical elements that need special attention in designing a modular building in similar seismic conditions is discussed with a deeper explanation of the behaviour of the overall system.

Calculation of Wind Loads on the Cladding of Apartment Building according to Panel Size (패널 크기에 따른 아파트 건축물 외장재의 풍하중 산정)

  • Cho, Kang-Pyo;Jeong, Seung-Hwan;Kim, Won-Sool
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.739-744
    • /
    • 2007
  • Wind loads for cladding can be estimated using the maximum wind pressure including gust effects from wind-tunnel tests. However, when estimating the maximum wind pressure with gust effects, wind pressure coefficients for cladding would be different according to the averaging time of wind pressures, In the paper, for wind pressures obtained from wind-tunnel tests for apartment buildings, whose window panes were damaged by actual strong wind, it was investigated how pressure coefficients varied according to the size of cladding and averaging time using TVL method of Lawson. In result, it was found that the lesser the size of cladding and averaging time were, the larger pressure coefficients became. Accordingly, to estimate wind loads for cladding of apartment buildings and design it, the averaging time of wind pressures should be considered properly.

  • PDF