• 제목/요약/키워드: building fire safety

검색결과 642건 처리시간 0.028초

Design of Smart Device Assistive Emergency WayFinder Using Vision Based Emergency Exit Sign Detection

  • 이민우;비나야감 마리아판;비투무키자 조셉;이정훈;조주필;차재상
    • 한국위성정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.101-106
    • /
    • 2017
  • In this paper, we present Emergency exit signs are installed to provide escape routes or ways in buildings like shopping malls, hospitals, industry, and government complex, etc. and various other places for safety purpose to aid people to escape easily during emergency situations. In case of an emergency situation like smoke, fire, bad lightings and crowded stamped condition at emergency situations, it's difficult for people to recognize the emergency exit signs and emergency doors to exit from the emergency building areas. This paper propose an automatic emergency exit sing recognition to find exit direction using a smart device. The proposed approach aims to develop an computer vision based smart phone application to detect emergency exit signs using the smart device camera and guide the direction to escape in the visible and audible output format. In this research, a CAMShift object tracking approach is used to detect the emergency exit sign and the direction information extracted using template matching method. The direction information of the exit sign is stored in a text format and then using text-to-speech the text synthesized to audible acoustic signal. The synthesized acoustic signal render on smart device speaker as an escape guide information to the user. This research result is analyzed and concluded from the views of visual elements selecting, EXIT appearance design and EXIT's placement in the building, which is very valuable and can be commonly referred in wayfinder system.

콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구 (A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete)

  • 권시원;오미현;곽규성;오상근
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

실측을 통한 융착식 플라스틱 입상배관 성능 평가 (An Applicability Estimation of Plastic Vertical Pipes using Electric Fusion Fittings through Measurement)

  • 박률;안영철;김현대;김정수;곽유식;김용경
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.595-599
    • /
    • 2013
  • The pipes used in buildings are generally categorized into metallic or plastic materials. Metal pipes, such as copper and stainless steel pipes, are mainly used for water and hot water supply, and for the heating system. However, plastic pipes made of polyethylene and cross-linked polyethylene are used for floor heating, water drainage, and air vent systems. Usually, plastic pipes have thermal demerits, such as high linear expansion coefficients and bending phenomenon by hot water, although the pipes have several merits of light weight, low price, low thermal conductivity, and the comparatively high workability of metal pipes. Therefore, if those kind of demerits are overcome, plastic pipes can be easily accepted for hot water systems. This research is aimed to evaluate the applicability for vertical heating pipes of a plastic pipe system consisting of electric fusion fitting of a conductive carbon compound and propylene random glass fiber pipe, through measurement of the expansion rate and leakage in summer and winter seasons, in the apartment construction field.

커튼월 건축물의 이중외피 시스템 적용에 따른 에너지 부하량 검토 (A Study on the Energy Load of the Curtain Wall Buildings according to the Application of the Double-skin Facade System)

  • 리바이홍;이준기;김성훈;이갑택;김동완;이경희
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.99-104
    • /
    • 2016
  • In this study, we researched the energy load according to the change of the inner window area ratio, the distance of the air gap and the azimuth of the curtain wall building, which installed the multistory double-skin facade(DSF). and we compared the results with the no double-skin facade situation as follows. With the DSF, it is better than other case, when the window area ratio is 40% and the air gap is 1.2m on the west, south-45-west, south-45-east and east. And it's best when the window area ratio is 40% and the air gap is 0.4m on the south. And on the east or south-45-east, the window area ratio is 40% and the air gap is 1.2m is better than other case with the DSF. On south, it is best when the window area ratio is 100% without DSF. On the south-45-west or west, it is best when the window area ratio is 40% without the DSF.

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • 제2권3호
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.

황토투수블록체를 적용한 친환경 조립식 빗물 침투형 저류시설의 구조 안정성 평가 (Structural Stability Evaluation of Eco-Friendly Prefabricated Rainwater Infiltration Type Detention Facility with Red Clay Water-Permeable Block Body)

  • 최형길;이태규;김호진;최희용
    • 한국건축시공학회지
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 2022
  • 최근 이상 기후에 의한 국지성 집중호우, 폭염 등의 빈번한 발생으로 통합적인 빗물관리 시스템의 도입이 필요하다. 따라서, 빗물침투와 저류를 동시에 구현함으로써 집중강우에 대한 홍수방지 뿐 아니라, 빗물침투를 통한 지하수위를 확보할 수 있는 경제적이며 친환경적인 빗물침투저류시설의 개발이 요구되고 있다. 본 연구에서는 황토를 포함한 친환경 무기질 결합재를 이용하여 만들어진 친환경 빗물침투저류시설의 구조적 안전성에 대해 검토했다. 상시하중과 부가적인 수직하중을 고려한 정적해석과 지진 스펙트럼을 고려한 동적해석을 수행했다. 그 결과, 본 연구에서 개발한 친환경 조립식 빗물 침투형 저류시설은 기존의 PE 블록 빗물저류시설과 비교하여 동일 하중조건 및 지진조건 하에서 발생되는 최대응력은 약 68.1% ~ 75.4%, 최대변위는 약 0.9% ~ 9.6% 수준으로서 우수한 구조적 안정성을 확보하는 것을 확인할 수 있었다.

철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측 (Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures)

  • 정우영;주부석
    • 한국지진공학회논문집
    • /
    • 제15권3호
    • /
    • pp.37-43
    • /
    • 2011
  • 구조물 내 설치된 파이프시스템은 주로 내부구성원들의 인간생활에 근간이 되는 기반시설로서 현대 도시생활의 생명선과 같은 역할을 한다. 이들 구조물 내 파이프시스템이 만약 지진발생에 의하여 손상될 경우 1차적으로 구조물 내 기능성이 저하되고 구조물 내 많은 정신적, 물질적 피해가 발생할 수 있다. 실제 내진공학에서 지진발생에 따른 비구조재요소의 거동은 크게 중요하게 고려되지 않으나 인적 및 물적 피해와 매우 밀접하게 연관되는 가스 혹은 수계파이프시스템에 대한 비구조적 요소의 거동예측 및 성능평가 연구는 보다 효과적인 구조물 유지관리를 위하여 그 필요성이 크다고 판단된다. 본 연구는 현재 일반적으로 널리 시공되어져 있는 노후 철근콘크리트 빌딩구조물 내 설치된 가스 혹은 수계파이프시스템에 대하여 실제 지진발생이 예측되는 거동을 살펴보고 이들 거동에 따른 성능평가 및 현 설계기준에 대한 검토도 병행하여 수행하고자 한다. 이를 위하여 본 연구에서는 해석적으로 발생 가능한 총 10회의 지진파에 대하여 현재 실제 건물 내 기설치된 수계파이프시스템 모델링 및 해석을 통하여 그 결과를 검증, 평가하였으며 부가적으로 실제 발생 가능한 파괴유형 분석을 통하여 현 설치된 수계파이프시스템의 설계에 대한 적절한 내진보강방법에 대하여도 제안하고자 한다.

학교 교실의 재실자밀도 기준 적정성 평가에 관한 연구 (A Study on the Adequacy Evaluation of Criteria of Occupant Load Density in School Classrooms)

  • 서동구;황은경
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.134-140
    • /
    • 2018
  • 본 연구는 학교 교실의 재실자밀도 기준에 대하여 학생 수 감소현상 및 지역별 편차 등에 의한 문제에 대응하기 위하여 기준의 적정성을 고찰하였다. 이에 교육부에서 제공하는 공시자료를 이용하여 유치원, 초등학교, 중학교, 고등학교 및 대학교 등에 대한 재실자밀도 기준을 분석하였다. 조사 결과, 학교 유형별로 데이터의 편차가 높게 나타났으며, 이에 중앙값을 나타내면 유치원($1.49m^2$/인), 초등학교($3.45m^2$/인), 중학교($2.64m^2$/인), 고등학교($2.45m^2$/인) 및 대학교 등($3.41m^2$/인)이 나타났다. 유치원을 제외한 재실자밀도 수치는 현 기준($1.9m^2$/인)보다 높은 것으로 나타났지만 최대 재실인원 산정의 목적을 고려하면 현재 기준은 즉시 개선은 필요하지 않은 것으로 판단되었다. 다만, 국가 교육정책의 개선 등의 영향에 따라 향후 개선을 한다면 조사결과를 토대로 $2.5m^2$/인으로 완화가 가능할 것으로 판단된다.

밀폐된 구획 내 일부 플라스틱류의 연기 특성 평가 (Evaluation of the Smoke Characteristics of Some Plastics in an Enclosed Compartment)

  • 유지선;강경신;이재승;정영진
    • 공업화학
    • /
    • 제34권4호
    • /
    • pp.421-425
    • /
    • 2023
  • Polymethyl methacrylate (PMMA), polycarbonate (PC), polyvinyl chloride (PVC), 그리고 polyacetal을 포함하는 일부 플라스틱류에 대한 연기특성을 조사하였다. 연기밀도는 ISO 5659-2의 기준에 의해 연기밀도시험기를 이용하여 정적인 연기 특성의 관련 값을 측정하였다. 또한 불꽃을 동반하는 연소와 불꽃을 동반하지 않는 연소를 구분하여 측정하였다. 불꽃방식의 복사열 50 kW/m2 의 조건하에서 연기의 최대비광학밀도(Dm) 측정값은 PMMA (401.26)가 최저로, PVC (1345.04)가 최대로 나타났다. 또한 비불꽃방식의 복사열 50 kW/m2 의 조건하에서 연기의 Dm 측정값은 PMMA (262.82) 가 최저로, PVC (1385.43)가 최대로 나타났다. 대상물의 연소 시 연기발생은 복사열 유속의 영향을 상당히 받으며, 탄화성 플라스틱은 연소 시 비탄화성 플라스틱보다 높은 연기 발생량을 나타내었다. 주 고분자 사슬에 방향족 그룹이 있는 폴리머는 열분해로 인해 다량의 숯이 생성되므로 다량의 연기를 발생시켰다.

건축공사의 공정관리를 위한 타워크레인 양중 효율성 분석 (Efficiency Analysis of Tower Crane Lifting Work for Project Management of Construction)

  • 배정현;김기혁;이동훈
    • 한국건설안전학회 논문집
    • /
    • 제2권2호
    • /
    • pp.63-69
    • /
    • 2019
  • 현재 빌딩 건설 프로젝트의 규모가 점점 더 커지고 있다. 이에 따라 다른 양중 장비보다 생산성이 높은 타워크레인 사용이 지속적인 증가하고 있는 추세이다. 그러나 무거운 물건을 운반하는 장비는 임대료가 비싸고 비효율적으로 운영되고 있으며 양중 작업의 생산성 및 효율성이 저하된다는 문제가 있는 것으로 분석되었다. 따라서 본 연구에서는 우선 현장에서 비효율적으로 운영되는 타워크레인을 조사한 후 타워크레인 작업에 영향을 미치는 항목들에 대한 점검 목록을 작성했다. 그 후 현장 방문을 통해 타워 크레인 점검표를 종합적인 데이터 가치로 도출했다.