A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics (성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구)

  • Seo, Dong-Goo;Lee, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

A Study on Domestic and Foreign Fire Cases for the Development of Korean Life Safety Standards (한국형 인명안전기준 개발을 위한 국내외 화재사례 조사)

  • Lee, Byeong-Heun;Jin, Seung-Hyun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.61-62
    • /
    • 2020
  • After the fire in Grenfell, a special fire safety survey was conducted, and the spirit of building fire safety is increasing. However, as can be seen from the fact that more than 80 people were injured in the Ulsan residential fire in 2020, there are no cases of making it a life safety standard for buildings, and there is an urgent need to investigate this. In this research, we will investigate the five fires that occurred in Grenfell, England, derive the problems, and use them as basic data for establishing the safety standards for Korean-style human life in the future.

  • PDF

Development of User-centered Fire Safety Evaluation Model for School Buildings (교육시설의 사용자 중심 화재안전수준 평가모형 개발)

  • Park, Sung-Chul;Kim, Jin-Wook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.238-239
    • /
    • 2021
  • This study presented the development of a user centered school facility fire safety evaluation model that would support fire safety evaluation, which is globally recognized as being important in terms of school safety, to be more efficiently implemented in the school field mainly by students. The study consisted of five steps. First, actual condition survey tools were developed based on the major fire safety evaluation items derived through literature review. Second, the characteristics of domestic school facilities in terms of fire safety were developed using the survey tools. Third, an evaluation model at a level utilizable by students was developed based on the foregoing characteristics. Fourth, the applicability of the model was verified through a trial application of the model to elementary school students. Finally, legal and institutional improvement plans and fire safety education materials were presented through a policy proposal.

  • PDF

An Experimental Study to Evaluate the Fire Risk of Building Windows (건축물 창호의 화재위험성 평가를 위한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.77-78
    • /
    • 2022
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame (건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

A Study on the Correlation of Analysis between Flashover and Smoke Production Rate in Building Structure (건축구조물에 있어서 플래시오버와 연기발생량의 상관관계 분석에 관한 연구)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.236-237
    • /
    • 2013
  • The fire safety design of performance is fire behavior inside buildings must be scientifically described and systemized as a theory, thereby allowing application to fire safety design of buildings. In this study, experiment of fire behavior according to disposition of combustibles were performed for correlation analysis between flashover and smoke production rate in building structure. As a result, smoke production rates is happened more than 80 m2/s in compartment(ISO 9705). Also, even if the fire load for flashover to if occur smoke did not, which confirmed that the delay time of occurrence.

  • PDF

Establishment of Performance Based Design Standardization of Fire Protection Systems for High-Rise Buildings (초고층 건축물의 화재안전성능 표준화 구축)

  • Son, Bong sei
    • Journal of the Society of Disaster Information
    • /
    • v.5 no.1
    • /
    • pp.66-74
    • /
    • 2009
  • As building heights increase, so do these challenges in Korea. High-rise buildings present a variety of challenges to fire safety and protection. The fire protection technology in our country is still on a weak situation which is mainly due to the lack of concerns by the government, companies and citizen. This paper provides general guidance regarding fire-related property protection system for high-rise building performance based design. The importance of high-rise building in of the number of occupants, the value of property, and the a catastrophic loss would have on the community all warrant an increased level of protection and life safety. Because, We have to prepare a new spacial code and standard guidance for fire protection at the stage of the high-rise building design.

  • PDF

An Experimental Study on Characteristics of the Residential Container Building Fire (주거용 컨테이너 화재 특성에 관한 실험적 고찰)

  • Lee, Jung-Yun;Jung, Ki-Chang;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.24-27
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Fire temperature and radiant heat flux were measured, in order to investigate the hazard-reduction effects during the fire emergency of residential container buildings. According to the test results, flash over occur in 10 minutes, peak fire temperature was $935.5^{\circ}C$, peak radiant heat flux was $24.99kW/m^2$ at 8minutes after residential container building fire.

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

A Study on Fire Scenario Analysis Based on Fire Statistics for Building Fire Risk Analysis (건축물 화재위험평가를 위한 화재통계 기반 화재시나리오 분석에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Koo, In-Hyuk;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.81-82
    • /
    • 2022
  • This study aims to establish a methodology for rational fire risk assessment for building evacuation safety in case of fire, and specifically, to propose a fire risk assessment technique using fire scenarios considering various uncertain factors in case of fire. In order to analyze the extent to which the assumed conditions can occur, that is, the probability of each accident caused by fire, the safety rate is analyzed according to the presence or absence of each factor by using fire statistics. Factors related to the fire protection performance and evacuation ability of buildings are defined as disaster factors. In this study, disaster factors were classified into the following three categories.