Research on Concrete Damage and Fireproofing Applications in Underground Fires (지하공간 화재에 따른 콘크리트 손상과 내화재 적용에 대한 연구)

  • Soon-Wook Choi;Soo-Ho Chang;Tae-Ho Kang;Chulho Lee
    • Tunnel and Underground Space
    • /
    • v.33 no.3
    • /
    • pp.169-188
    • /
    • 2023
  • Fires in tunnels are characterized by higher temperature rise and higher maximum temperatures compared to ground fires. For this reason, countries such as the Netherlands and Germany have developed separate temperature-time curves for use in tunnel fires. Fires in tunnels cause damage to the tunnel lining, such as loss of section and deterioration of the material properties. This study reviewed the design concept of fire stability of structures, section loss due to spalling, changes in physicochemical and mechanical properties of tunnel lining materials, fireproofing materials for structure safety, and fire damage prediction models. In order to secure the stability of a structure against fire, it is necessary to identify the type of structure and the possible fire load at the design stage, identify the expected section loss and damage range, and prepare for such damage through fireproofing materials. In this study, we have summarized the matters that can be referred to in performing such a series of tasks and presented our opinions on them.

An Analysis of the importance in fire-stations' works and redesign by disaster management steps (재난관리 단계별 소방업무 중요도분석 및 업무재설계)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.572-582
    • /
    • 2014
  • Fire-stations' works limited to the existing fire protection rescue and emergency services in rapidly changing disaster environment are not difficult to deal with the fire service demand of the people any longer. In this study, after calculating the importance of the disaster management about fire-stations' works by disaster management steps thorough a survey of experts about Fire and Disaster, firefighting tasks are to be redesigned. Experts have the higher rating in preparation step of firefighting tasks. Because securing resources and building systems in preparation step and safety training in prevention step have a high importance, it is required to improve efficiency of firefighting tasks through redesign. The most important point in redesign is to realize fire-stations' works are to expand and to develop such a policy if fire-offices excavate the civil and government cooperation works and provide such legal and institutional basis of establishment and operation. And it should be sought to maintain international cooperation for international disaster response. Ultimately, fire-offices will have further expansion in quality and simultaneously quantitatively by excavating 'collaboration (business cooperation)' or enhancing existing works in addition to existing 'fire and rescue, first aid' business.

A Study on the Status of Waterproof Pressure of Indoor Hydrant Proportioner by a survey (옥내소화전의 방수압 실측에 의한 실태조사 연구)

  • Choi, Kyu-Chool;Jeong, Sang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.255-263
    • /
    • 2009
  • A indoor hydrant proportioner that is installed as fire extinction equipment when a fire breaks out in a building plays a vital role for a fire extinction at an early stage. The indoor waterproof hydrant proportioner installed currently can function in case of fire as fire extinction equipment only when it can maintain proper waterproof pressure meeting the standards stipulated in NFSC. The results of the survey on the waterproof pressure of the indoor hydrant proportioner installed in most buildings showed that the waterproof pressure installed inside the buildings was higher than the agreed level suggested by NFSC, which is very desirable state and is regarded as the results of fire facilities being maintained and managed by regular fire inspections. It is thought that the safety management of fire extinction facilities should be kept up both regularly and steadily through TAB.

  • PDF

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Study on an Adaptive Guidance Plan by Quickest Path Algorithm for Building Evacuations due to Fire (건물 화재시 Quickest Path를 이용한 Adaptive 피난경로 유도방안)

  • Sin, Seong-Il;Seo, Yong-Hui;Lee, Chang-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.197-208
    • /
    • 2007
  • Enormously sized buildings are appearing world-wide with the advancement of construction techniques. Large-scaled and complicated structures will have increased difficulties for dealing with safety, and will demand well-matched safety measures. This research introduced up-to-date techniques and systems which are applied in buildings in foreign nations. Furthermore, it proposed s direct guidance plan for buildings in case of fire. Since it is possible to install wireless sensor networks which detect fires or effects of fire, the plan makes use of this information. Accordingly, the authors completed a direct guidance plan that was based on omnidirectional guidance lights. It is possible to select a route with concern about both time and capacity with a concept of a non-dominated path. Finally, case studies showed that quickest path algorithms were effective for guiding efficient dispersion routes and in case of restriction of certain links in preferred paths due to temperature and smoke, it was possible to avoid relevant links and to restrict demand in the network application. Consequently, the algorithms were able to maximize safety and minimize evacuation time, which were the purposes of this study.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

A Study on the Review of Repair Methods and Repair Materials for the Prevention of Fire spread of Building Exterior Materials (건축물 외장재의 화재확대방지를 위한 보수구법 및 보수재료 검토에 관한 연구)

  • Lee, Byeong-Heun;Jin, Seung-Hyeon;Park, Sung-Ha;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.105-111
    • /
    • 2019
  • In Korea, the results of a field survey on the construction of flammable exterior materials implemented in 2018 revealed that 147,559 buildings belong to this category. It was found that the fire spreading cases in upper and adjacent constructions are about 3,500 per year, the fires of starting in flammable exterior material are about 1,500 per year. In this study, we investigated the repair method of buildings constructed by flammable exterior material and conducted performance verification of each repair materials for prevention of similar fire. In the case of the repair method, a method of reinforcing with a repair material after removing the existing building finishing material and a method of attaching the repair material after performing the face finishing are proposed. In addition, we conducted cone calorimeter tests of 6 materials such as fireproof gypsum board, mineral wool, hard urethane foam, ceramic board and ALC panel as dryvit and repairing materials, and investigated basic combustion performance of that materials.

Numerical Study on the Effect of Damper Position on Characteristics of Thermal Flow at the Vestibules and Fire Door (댐퍼의 위치가 부속실 및 방화문에서의 열 유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Moon, Hyo-Jun;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The pressurized smoke control system is important for fire safety in building because it is directly concerned with egress time of people. Even though the damper plays an essential role in the pressurized smoke control system, the phenomena of backflow smoke occurs for a certain the damper position. The research for a position of damper effects on distribution of air flow at the fire door is not performed. In this study, numerical simulation using FDS 5.5 was carried out to analyze the effect of the position of damper on flow distribution at the fire door. To simulate real situation, effects of opening and closing of fire door was considered. As a result, when HRR was between 200 kW and 400 kW, in the case which the damper was on the opposite wall of the fire door, the back flow to the vestibules was large compared to the two other cases of damper position. But when HRR was above 400 kW, Effect on damper position was not occurred.

Action Plan of Security Service against a Fire case in a Tall Building Event (경호행사시 초고층건물 화재 대응방안)

  • Son, Kyung-Hwan
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.37-61
    • /
    • 2014
  • Nowadays the world is threatened because of terrors that take aim at Soft-Targets available and easy to access to the people rather than more secured Hard-Targets. The inspection department of the Presidential Security Service develops and acts a perfect safety plan wherever the President stays so that it is possible to get immediate actions for various contingencies. Some events, in which the President take part, could be held in a lower or higher store in a tall building. Additional to the routine work at this case it is to emphasize on a plan of fire precaution to check the spot and respond to a real fire situation, so that the damage could be minimized. First, the agents of the President Security Service should possess basic knowledge concerning to the fire accidents and be trained on their manuals, even in a busy events plan. An organization, whatever it is, could be improved in that it tries to develop not only the personal abilities, but also education programs of the organization continually. And enhanced abilities of the members lead to the driving force for the advance. The knowledge of fire accident should be able to adapt to the real situation. Second, related to the event, it should be cooperated with the relevant departments, so that it is possible to conduct and control the system. It is urgently required to know that the security event could not be done perfectly with only one part or department. Third, from the time of recognizing of the event it is necessary for the fire department to get an action plan with fire fighting measures, evacuation measures based of the instructions given by the Security Service. Fourth, on the knowledge of the action plan of the fire department the Security Service should inspect the safety activities of the spot and establish the practical operation plan through the fire fighting and evacuation plan. Fifth, the Security Service should share final informations and plan of fire fighting in a high-rise building with the other relevant departments. If not, it could cause a great confusion that could lead to a great damage.

  • PDF