• Title/Summary/Keyword: building fire safety

Search Result 644, Processing Time 0.024 seconds

Development of a Real-time Safest Evacuation Route using Internet of Things and Reinforcement Learning in Case of Fire in a Building (건물 내 화재 발생 시 사물 인터넷과 강화 학습을 활용한 실시간 안전 대피 경로 방안 개발)

  • Ahn, Yusun;Choi, Haneul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.97-105
    • /
    • 2022
  • Human casualties from fires are increasing worldwide. The majority of human deaths occur during the evacuation process, as occupants panic and are unaware of the location of the fire and evacuation routes. Using an Internet of Things (IoT) sensor and reinforcement learning, we propose a method to find the safest evacuation route by considering the fire location, flame speed, occupant position, and walking conditions. The first step is detecting the fire with IoT-based devices. The second step is identifying the occupant's position via a beacon connected to the occupant's mobile phone. In the third step, the collected information, flame speed, and walking conditions are input into the reinforcement learning model to derive the optimal evacuation route. This study makes it possible to provide the safest evacuation route for individual occupants in real time. This study is expected to reduce human casualties caused by fires.

Verification of firefighters' heuristics through big data analysis (빅데이터 분석을 통한 소방관의 경험법칙 검증 및 화재예방 활용)

  • Park, Sohyun;Park, Jeong-Hoon;Shin, Eun-Ji;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.50-55
    • /
    • 2020
  • The heuristics accumulated in the field activities of firefighters were reviewed through big data analysis of fire occurrences in Gyeonggi-do and researched to be utilized for proper fire prevention activities according to time, day, and target through quantitative modeling. Empirical rules with high sympathy were collected through direct interviews with firefighters. Among them, the rule of thumb that "Friday is the most fire-prone" is considered to be the most important in terms of fire monitoring and prediction. A big data comparison analysis was conducted, including the number of fires and damages that occurred in Gyeonggi-do in 2018. Furthermore, fire occurrence patterns by region, day of the week, time of day, and building type were derived. Regarding empirical rules that have been validated through research, relatively inexperienced firefighters also can make decisions by relying on refined quantitative predictive modeling and empirical rules including local government and time-based factors that reflect big fire occurrence data.

The Study on the Development of PBD Manual according to comparison Each country criteria (국내외 기준 비교를 통한 한국형 성능위주설계 지침서 개발에 관한 연구)

  • Koo, Tae-Yoon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.31-32
    • /
    • 2017
  • The Korea is conducted performance based on design according to fire fighting law in 2009, but it came out problems related to PBD consistently. Especially, there is no specific guideline or code related to evacuation safety verification. so it came out different results according to designer. This study is looking for each country criteria and suggest the basis data for Manual composition through comparison.

  • PDF

A Comparative Study of Tensile Strength of Architectural Membrane using Basalt Fiber (현무암섬유 기반 건축용 막재의 강도 비교 연구)

  • Kim, Ji-Hyeon;Shin, Hyeon-Uk;Song, Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.149-150
    • /
    • 2016
  • The membrane structure is being applied in structures for various uses for its many advantages as permeableness, lightweightness, constructability, resource saving, and management cost reduction, and the usage is being expanded. However, despite the development of membrane structure, the standard for architectural membrane performance that considered fire safety is still inadequate. Therefore, this study applied basalt fiber with flame resistance on architectural membrane. Also, this study confirmed the membrane applicability of basalt fiber through comparison with existing architectural membrane.

  • PDF

Density and Strength Properties according to the Paper Ash addition ratio of the Lightweight Composite Panel Core Using the Blast Furnace Slag and Polysilicon Sludge (고로슬래그와 폴리실리콘 슬러지를 활용한 경량복합패널 심재의 제지애시 첨가율에 따른 밀도 및 강도특성)

  • Lim, Jeong-Geun;Lee, Ji-Hwan;Park, Hee-Gon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.152-153
    • /
    • 2015
  • Recently, solar energy generation is one of the fastest growing industries for eco-friendly energy. Every year, solar energy generation industry grows to 42% on average. However, polysilicon sludge is generated from processing of polysilicon but, there is nothing to handle that. Therefore, we need research to recycle polysilicon sludge. Also, improved fire resistance efficiency of wall is required according to reinforced fire safety standards due to many cases of big fires in our country. This study focuses on density and strength properties according to the addition ratio of paper Ash for the lightweight composite panel core with polysilicon sludge. As a result of the test, adding paper ash 9% has the best density and strength properties.

  • PDF

Experimental study on smoke-logging phenomenon caused by sprinklers during a compartment fire (구획 화재시 스프링클러에 의한 스모크-로깅현상에 관한 실험적연구)

  • Kwon, Young-Jin;Yoon, Ung-Gi;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.121-122
    • /
    • 2014
  • This study contemplated the descending air current from the smoke layers related to the smoke logging phenomenon in the sprinkler applied design for effective evacuation safety design. As a result, database on the average particle diameter, particle velocity and distribution of sprinkling was obtained and the relationship between the water amount and particle diameter was obtained. Also, in relation to descending air current, the movement of smoke layer to the bottom at the descending air current velocity of 0.6m/s was observed and stable descending air current was observed in existence of fire source over 100kW in size.

  • PDF

Research on the Cognition and Education of Safety for Children (아동의 안전에 관한 인식과 교육 실태 조사 연구)

  • 이한용;우종웅;김일영
    • Korean Journal of Health Education and Promotion
    • /
    • v.18 no.3
    • /
    • pp.59-75
    • /
    • 2001
  • It is necessary to examine from primary school children's viewpoint to perception of safety as to how they cope with a condition threatening safety at the realistic world with risky environment and whether knowledge obtained through education is transmitted to action in a correct way. For this, this study explored and analyzed children's perspective to safety felt in life, their achievement of education to safety as trainees, and their perception extent to safety. As a result of it, following conclusion could be obtained. First, as for safety on their way to school and home, the lower grade they were, the more they felt safe, but the higher they were, the more they felt uneasy, which was examined that they generally had uncomfortable mind. Second, as for whether safety education was performed or not, it was indicated that safety education was generally executed, but lower graders responded that safety education was executed, but high graders responded that it was not executed. Third, as for observance of traffic rules, it was examined lower graders kept them well, but higher graders did not do so. Fourth, as for safety of play, it was indicated lower graders wore protective equipment by parents' concern, but higher graders did not wear them since they were full of confidence counting on their capability. Fifth, as for life safety, it was indicated the area most preferentially educated from parents' viewpoint was traffic safety, and the next ones were gas and fire safety. Sixth, as for fire safety, it was indicated they did not play with fire, but higher graders compared to lower ones, played with fire as the means of curiosity and play. Thus, curricula for children's safety education executed from adults' viewpoint should be established, and assessment of children's safety education should get out of the limitation of execution of safety education to habituated action by the transmission of children's knowledge. Also it is urgent to develop programs with which to perform children;'s education at the level of children, establish and operate safety education facilities for practice education that teachers and children can receive safety education through experience by building up children's safety education related entities. And it is thought that safety should not left to only children, but their safety would be kept by developing and training safety education programs to all organizations and individuals related to safety.

  • PDF

A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR (콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구)

  • Han, Bong-Hoon;Seo, Dong-Ho;Kwon, Young-Hee;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.23-32
    • /
    • 2017
  • Foam block, popularized as the self-interior goods, is susceptible to fire since the main material is the polyethylene flammable synthetic resin. However, it is widely used in homes, offices, and multi-use facilities. In order to understand the fire characteristics of the foam block, two kinds of foam blocks sold in the market (non-fire retardant and fire retardant) were evaluated according to standard of KS F 5660-1 (Reaction to fire test). In addition, the hazard analysis of the gas generated by the combustion of the specimen was performed using the FTIR gas analyzer. The cone calorimeter test showed that the ignition and flame combustion of both two specimens were burned as soon as the radiant heat blocking device was removed, and it was confirmed that the flame could become a rapid propagation factor during the fire. The analysis of the combustion gas through the FTIR gas analyzer showed that both the carbon dioxide and carbon monoxide classified as the common combustion gases and the acrolein, ammonia, and hydrogen cyanide causing serious damage to the human body were detected substantially. This study showed that a foam block product has high ignitionability and generates toxic gases. Hence, it is urgently required to establish the standards used for properly classifying the combustion characteristics of the material on the basis of the use conditions of a foam block product and to prepare the standards on the purpose of use.

Research on Fire Safety of Mortar-Containing Waste Tire Powders and Flame Retardant (폐타이어 분말과 난연제가 혼입된 모르타르의 화재안전에 관한 연구)

  • Park, Jeong-Jin;Son, Ki-Sang
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.12-17
    • /
    • 2010
  • The purpose of this study is to determine how effectively waste tire recycled material mixed with flame retardant work in combating fire. As discovered in the previous study, waste tire mixed with cement mortar has more insulation capacity. However, this mortar is weak against fire. Therefore flame retardant, with a specific proportional mix, will be added to increase its fire prevention capacity. Tests will be made in accordance with ISO 5657 procedures for measuring fire ignition time, flame and shape variation of test pieces at the Building Material Test Institute. The test piece will be set up with horizontal levels having a constant radiation heat of $1{\sim}5W/cm^2$. Temperature transfers and increases from the surface into the interior. Combustible gases result due to pyrolysis, and regular contact is maintained between the fire source and the center of the test piece for assessment purposes. Ignition has not been occurred without adding retardant meaning that there is almost no possibility of ignition of waste tire particle. This fact can be considered as fire load to appreciate a volume of combustion materials. Flame is not occurred due to heat-absorbing effect by adding non-organic series retardant into waste tire particle. Conclusions have been summarized as follows; 1) Combustion of building material can be decreased by adding retardant to waste tire-mixing mortar. But compressive strength and insulation capacity of the material should be measured later. 2) Firing prevention and ignition are main points of building fire. Reasonable fire engineering assessment of interior material should be made for establishing effective disaster prevention system.

A Numerical Study on Effects of Flow Through Openings on Convection (개구부의 유동이 대류에 미치는 영향에 관한 수치연구)

  • 박외철;이경아
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.52-56
    • /
    • 2000
  • The finite control volume method was utilized to investigate the effects of flow through openings on convection in an enclosure. Flow patterns and temperature distribution were compared for non-dimensional inflow velocity U=20, 40, 60 at Ra=$10^4$ and $5\times10^4$, respectively. The inflow velocity influenced temperature distribution in the enclosure significantly and lowered temperature on the top wall. The flow through openings forced the position of the highest temperature on the top wall to move toward the outflow opening.

  • PDF