• Title/Summary/Keyword: building fire safety

Search Result 644, Processing Time 0.026 seconds

A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (II) (일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사(II))

  • Lee, Jae-Won;Kim, Dong-Eun;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.316-321
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

A Study on the Inland Signal-fire in Chosun Dynasty (조선시대 내지봉수에 관한 연구)

  • Yoon, Jae-Woong;Lee, Chul-Young
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.47-64
    • /
    • 2009
  • This research was to analyze the inland signal-fire which is the main facility of military protective duty for safety of land in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, oval, rectangular, indeterminate form. The majorities were oval type. 2. Plan configuration of brazier which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of brazier was about 3~4.5m. The diameter of brazier was 1.5~2.5m. Building base that protect ground moisture and infilteration of rainfall was found in 5 inland singal-fire, the height of it was about 0.3m~2.5m. 3. The heigh to protective wall remained until present was about 1m, the depth was about average 1.2m. 4. Entrance was mainly stairs or open type and average width was 1.0~1.2m. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 5. The storage of inland signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the brazier.

  • PDF

Analysis of Fire Characteristics based on the Thickness and Incident Heat Flux of Wood (합판류 목재의 두께별 입사열유속에 따른 연소특성 비교 연구)

  • Hwang, Sun-Woo;Park, Won-Hee;Kim, Chang-Yong
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.13-21
    • /
    • 2020
  • This study tested the wood used in building interiors; each type had various incident heat fluxes based on their thickness. The combustion characteristics measured were effective heat of combustion, heat release rate peak and arrival time, maximum average rate of heat emission, and piloted ignition temperature. The wood specimens used in the experiment were 4.8 to 18 mm thick. 25, 35, 50, and 60 kW/㎡ were applied to the incident heat flux that the wood specimens were exposed to. The wood specimens tested were two types of medium-density fiberboard (each with a different density), treated red pine, particle board, and plywood. A comprehensive comparison of different fire characteristics was conducted to analyze the fire patterns corresponding to each type of wood in this way, the risk of fire was studied. The risk of fire was particularly high for particle board. The results of quantifying the fire characteristics of the types of wood studied could function as important input data with which to calculate the fire load of composite combustibles.

A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot (지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구)

  • Song, Young-Joo;Kong, II-Chean;Kim, Hak-Jung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • Today, building constructions are becoming larger, higher, deeper, and complex to improve quality of human life and meet various needs. As a result, new design space for non - typically standardized space has been created, and targets for performance-based design are also becoming increased. An evacuation safety evaluation of performance-based design should be compared with ASET and RSET estimation so that the value of RSET does not exceed the value of ASET. However, there is a problem that it is difficult to secure the safety with using the performance-based design evaluation method currently in use, especially in case of the underground parking lot, because it has wide compartment area and various routes for evacuation. Therefore, in order to overcome these problems, this paper first investigates the simulation setting method of the performance-based design that is currently in use, and then conducts two fire simulations and three evacuation simulations for underground parking lots each time, so performs the evacuation safety evaluationin total six cases of situations. Here this paper analyzes the problem with comparative evaluation research and suggests the better solution for improved evacuation safety evaluation of performance-based design.

An Study on the Preparation of Fire Behavior of Fixed Combustibles for Fire Simulation in Building (건축물의 화재성상 시뮬레이션을 위한 주요가연물 연소특성 DB 구축)

  • Seo, Yoon-Jeong;Kim, Dong-Eun;Hong, Hae-Ri;Hwang, Hyen-Bea;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.73-76
    • /
    • 2011
  • 최근 건축물에서 공동주택의 비율이 증가하고 있으며 동시에 공동주택의 화재비율도 증가하는 경향을 보이고 있다. 또한 화재 시 인명 피해의 주원인인 가연물은 소재가 다양화되고 있으나 안정성 보다는 디자인, 기능성에 치중되어 그에 따른 화재 위험성도 커져가고 있다. 따라서 본 연구는 전보의 실내장식물에 이어 공동주택에서 많이 사용되어지는 적재가연물을 가연물 조사를 바탕으로 선정하여 Furniture Calorimeter를 이용해 그 연소특성을 알아보았다. 그 결과, 소파가 타 시료에 비해 화재 시 높은 위험성을 나타냈으며, 일본건축학회에 발표된 데이터와 비교한 결과 소파의 데이터가 유사한 것으로 나타났다.

  • PDF

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Study on the Activation·Specification of 119 Rescue & Care in JeJu (제주도 119구조·구급대의 활성화 및 전문화 방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.153-168
    • /
    • 2002
  • Since 1992, conventional fire fighting businesses have been converted into a metropolitan autonomous fire fighting system to be ready for a variety of disasters. However, the corresponding investment has been overlapped due to the non-integration of businesses to prevent any potential disasters, and a series of collaborative systems have been not functioning so well. In the meantime, our fire fighting sector has been trying to set up its own clean and faithful position by abolishing any inconvenient system or outsourcing private sectors, and expanded its work scope from conventional fire fighting even to rescue and emergency works. While focusing on handling disaster, the fire fighting sector has been widely trusted and reliable throughtout our nation. Moreover, our fire fighting sector has secured nation wide mobile organizations, technical personnel by field, special equipments and independent communication network. In addition, the fire fighting sector has knowledges, expertise and capabilities required for managing disasters, while in charge of almost every disaster management works including fire, explosion, collapse, disaster and flood. It becomes an organization for comprehensive disaster management under an absolute national trust, which is based on the system for prevention, preparation and countermeasure against a variety of disasters. Thus, our fire fighting sector must make many efforts and try to modernize conventional education and training. The ways to facilitate rescue and emergency works may include the nurture of technical fire fighting personnel along with modernized equipments, the reinforcement of rescue and emergency education, the facilitation of operating civil defense corps, the facilitation of operating volunteer fire fighting corps, the better arrangement of 119 briefing room for public healthcare in provincial offices, the sterilization of rescue instruments and equipments the better repair education for emergency rescue member, the establishment of regional emergency assistant system and the expansion of fire fighting personnel and equipments. In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations: Building up security system along with operational expansion, building up a system for emergency medical treatment, building up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119 we can review the following considerations : Improving the education for fire fighting training corps under Jeju Provincial Fire and Disaster Management Department, providing rescue members with more opportunities for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. If these requirements are met, it is expected that the fire fighting departments in Jeju province can cope with every accident and disaster a little more rapidly and quickly in compliance with local needs, so that they can keep their own position as a public fire fighting organization which may be trusted by the public.

  • PDF

An Investigation Study on the Evacuation Capacity Computation for the Development of Korea Life Safety Code (한국형 인명안전기준 개발을 위한 피난용량 산정에 관한 연구)

  • Koo, In-Hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.65-66
    • /
    • 2020
  • When evacuation safety Design of buildings, the calculation of evacuation capacity is the most important factor that it directly impact of evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, in this study we anlayze the evacuation capacity standards of each countries as basic study for development the Korean Life Safety Standards

  • PDF

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.