• Title/Summary/Keyword: bubble mark

Search Result 5, Processing Time 0.017 seconds

Manometer Scale Mark Formation using Thermal Reaction For Storage Application (열 반응을 이용한 나노사이즈 마크형성)

  • Jung, Moon-Il;Kim, Joo-Ho;Hwang, In-Oh;Kim, Hyun-Ki;Bae, Jae-Cheol;Park, In-Sik;Kuwahara, Masashi;Tominaga, Junji
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.127-131
    • /
    • 2005
  • We report a nanometer scale mark formation using a $PtO_x$ thin film or a TbFeCo rare-earth transition metal film and the mechanism. The multi-layer samples($ZnS-SiO_2/PtOx/ZNS-SiO_2,\;ZnS-SiO_2/TbFeCo/ZnS-SiO_2$) were prepared with a magnetron sputtering method on a polycarbonate or a glass substrate. By laser irradiation of approximately a few nanoseconds, nanometer scale marks were fabricated. During the fabrication process, the thin films were thermally reacted or inter-diffused during the laser irradiation. 75 nm bubble marks in the PtOx multi-layer sample by an approximately 4-ns laser irradiation. Inside the bubble mark, Pt particles with a few nanometer sizes are distributed. The $50{\sim}100$ nm bubble marks in the TbFeCo multi-layer sample by a few nanosecond laser irradiations. We will report the detail structure of the samples, the bubble mark formation process and the mechanism.

  • PDF

Improvement of Noise Characteristics in Super-RENS Disc (Super-RENS 디스크의 노이즈 특성 향상)

  • Kim, Joo-Ho;Hwang, In-Oh;Kim, Hyun-Ki;Park, In-Sik;Bae, Jae-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • The research topic of super-RENS technology is shifting from the signal intensity (CNR; Carrier to Noise Ratio) to the signal uniformity (Jitter or bER). To achieve an uniform signal characteristics, it is important to reduce signal fluctuation in a super-RENS disc. In this study, we investigated the relation between signal fluctuation and low frequency noise (LFN), and analyzed LFN increase in recording and readout processes. It was found that signal fluctuation had a close relationship with the LFN. Also, it was found that the recorded mark shape such a bubble type and high readout power increased the LFN in recording and readout process of a super-RENS disc. So, using non-bubble type recording material and low super-resolution readout material, we markedly improved the LFN in a super-RENS disc.

  • PDF

Changes of Potassium in Open Heart Surgery (개심술시의 포타시움 변화)

  • 이홍섭
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.422-427
    • /
    • 1978
  • Alterations in the serum and urine potassium were studied in twenty patients who underwent open heart surgery in National Medical Center during the period from Jan.1978 to June 1978. There were twelve cases congenital heart disease and eight acquired heart disease. Rigg-Kyvsgaad mark IV roller pump and Polystan bubble oxygenator were used in all patients. Hemodilution was carried out by priming the oxygenator with Hartmann`s solution. Measurements were made of the serum electrolyte, gas analysis and twenty four hour urine electrolytes. During the bypass, the serum potassium decreased Significantly from 4.2?.47 to 3.6?. 72 mEq. per liter. [p<0.05] Fifty seven miliequivalant of potassium chloride were added during operation-urine potassium was higher in the diuretic group than in the non diuretic group. Plasma potassium level in the diuretic group was more significantly reduced than nondiuretic group. In this series large amount of urine potassium loss was noted on the day of operation, the first and second post operative day.

  • PDF

Heat Flow Analysis of Ferritic Stainless Steel Melt during Ti wire feeding (Ti 와이어 피딩에 따른 페라이트계 스테인레스강 제강시 열유동 해석)

  • Kim, Min-Gi;Hwang, Dong-Chan;Choi, Jae-Joo;Shin, Sang-Yoon;Ye, Byung-Joon;Kim, Ji-Hun;Kim, Won-Bae
    • Journal of Korea Foundry Society
    • /
    • v.29 no.6
    • /
    • pp.277-283
    • /
    • 2009
  • Recently an increase in production cost of 300 series stainless steel with a sudden increase in nickel cost has caused a decrease in demand for 300 series stainless steel so that 400 series stainless steel has begun to make a mark. Although 400 series stainless steel has good properties, it has a problem of lack of corrosion resistance. There is Ti in 400 series stainless steel alloys to solve the problem above and it has lower density than the others. For that reason, wire feeding process has been applied for adding Ti alloy in 400 series stainless steel. This paper presents consideration of variation on the depth of wire dissolution by conditions of wire feeding which are wire injection speed, the temperature of molten steel, wire diameter and bubble generation rate. The computer program for solution of conducting wire feeding has been developed in Flow3D.

Experimental Studies on Extracorporeal Circulation by Rygg-Kyvsgaard Heart-Lung Machine, Hartman`s Solution Prime,and Moderate Hypothermia: [Part I] (Hartmann`s 용액으로 충진한 혈희석 체외순환에 관한 실험적 연구: (1보: 심폐기 Rygg-Kyvsgaard 의 혈산화와 혈압 및 혈액상에 미치는 영향))

  • 지행옥
    • Journal of Chest Surgery
    • /
    • v.4 no.2
    • /
    • pp.69-80
    • /
    • 1971
  • Total body perfusion using Rygg-Kyvsgaard Heart-Lung-Machine, Mark IV, Polystan was attempted in the dogs by the hemodilution method with total prime of buffered Hartman's solution and under hypothermia. The first of all, the functions of Rygg--Kyvsgaard Heart-Lung-Machine and the effects of the hemodilution perfusion by buffered Hartman's solution was studied. At the same time the changes of blood pressure, oxygen consumption, and influence on the blood pictures were observed before, during, and in 1-3 days after perfusion. Hemodilution rates were the average 74. 22cc/Kg(the ranges of 67 to 81 cc/Kg) and perfusion flow rates were maintained in the mean 62. 6cc/Kg/min., Although it was possible to check up to 87 cc/ Kg/min. The total body perfusion continued for 60-80 minutes. Hypothermia was employed between $36^{\circ}C$ and $32^{\circ}C$ of the rectal temperature. Arterial pressure was ranged approximately between 68mmHg and 149mmHg, but generally, it was maintained over 80mmHg. Venous pressure was measured between 6.5cm $H_2O$and 11.5cm $H_2O$. Optimum oxygenation can be expected when oxygen flow into the disposable bubble oxygenator was maintained approximately at 3.5 L/min .. Inthis way, the oxygen contents were measured in the mean value of 13.11${\pm}$O.56 vol. % of arterial blood and 8.67+1.08 vol.% of venous blood(P${\pm}$0.86 vol.% in arteriovenous oxygen difference and 2. 97${\pm}$0.62cc/Kg in oxygen consumption were calculated. According to these dates, it is as plain as pikestaff that excellent oxygenation and good tissue perfusion was accomplished. Erythrocyte, hemoglobin and hematocrit were decreased about 38% during extracorporeal circulation and these were not recovered until 1-3 days after perfusion. These decrease was resulted from relatively high degree of hemodilution rate and no blood transfusion to compensate during these experimental studies. The platelets were also decreased about 76% during perfusion, but on the contrary, it was increased progressively after perfusion and in 1-3 days after perfusion was returned to the control level. Leucocyte were also decreased during perfusion, but it was increased progessively after perfusion and in 1-3 days after perfusion exceed the control level. This increase was resulted from postoperative infection of the wound, but its analysis were not changed significantly.

  • PDF