• Title/Summary/Keyword: bridge sites

Search Result 143, Processing Time 0.021 seconds

Determination of the Origin of Particulate Organic Matter at the Estuary of Youngsan River using Stable Isotope Ratios (${\delta}^{13}C$, ${\delta}^{15}N$) (탄소 및 질소 안정동위원소 비를 이용한 영산강하구역 유기물 기원 추정 연구)

  • Lee, Yeon-Jung;Jeong, Byung-Kwan;Shin, Yong-Sik;Kim, Sung-Hwan;Shin, Kyung-Hoon
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2013
  • Organic carbon and total nitrogen stable isotope ratios of suspended materials were determined at 3 stations (from Mongtan Bridge to Youngsan river estuary barrage) (n=6, each) from November 2008 to August 2009, in order to understand the origin of particulate organic matter at the Estuary of Youngsan River. Allochthonous organic matter, ammonia-N and silicate were increased after heavy rain (in August). Carbon isotope ratios were significantly different between stations in November and August, and it was possible to determine the origin of organic matter. The heavier nitrogen isotope ratios, as well as higher phosphate concentrations, were found in November than other sampling times. Livestock wastewater and farmland input was likely the main causes of these high values. In addition, YS3 station, the nearest site to estuary barrage, appears to be affected by a substantial amount of livestock wastewater and farmland input, considering that nitrogen isotope ratios were heavier than those at the upper sites. These results suggest that the analysis of stable isotope ratios is a simple but useful tool for the determination of organic matter origin in aquatic environments.

Sensitivity Identification Method for New Words of Social Media based on Naive Bayes Classification (나이브 베이즈 기반 소셜 미디어 상의 신조어 감성 판별 기법)

  • Kim, Jeong In;Park, Sang Jin;Kim, Hyoung Ju;Choi, Jun Ho;Kim, Han Il;Kim, Pan Koo
    • Smart Media Journal
    • /
    • v.9 no.1
    • /
    • pp.51-59
    • /
    • 2020
  • From PC communication to the development of the internet, a new term has been coined on the social media, and the social media culture has been formed due to the spread of smart phones, and the newly coined word is becoming a culture. With the advent of social networking sites and smart phones serving as a bridge, the number of data has increased in real time. The use of new words can have many advantages, including the use of short sentences to solve the problems of various letter-limited messengers and reduce data. However, new words do not have a dictionary meaning and there are limitations and degradation of algorithms such as data mining. Therefore, in this paper, the opinion of the document is confirmed by collecting data through web crawling and extracting new words contained within the text data and establishing an emotional classification. The progress of the experiment is divided into three categories. First, a word collected by collecting a new word on the social media is subjected to learned of affirmative and negative. Next, to derive and verify emotional values using standard documents, TF-IDF is used to score noun sensibilities to enter the emotional values of the data. As with the new words, the classified emotional values are applied to verify that the emotions are classified in standard language documents. Finally, a combination of the newly coined words and standard emotional values is used to perform a comparative analysis of the technology of the instrument.

Load Transfer Mechanism of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 하중전이기구)

  • ;Cho Sung-Min;Jung Sung-Jun;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.187-196
    • /
    • 2005
  • Since the allowable bearing capacities of piles in weathered/fractured rock are mainly governed by settlement, the load-displacement behavior of pile should be known accurately. To predict pile head settlement at the design stage, the exact understanding of the load-transfer mechanisms is essential. Therefore, in this research, the load-transfer mechanism of drilled shaft socketed into weathered rock was investigated. For the investigation, five cast-in-place concrete piles with diameters of 1,000 mm were socketed into weathered gneiss. The static axial load tests and the load-transfer measurements were performed to examine the axial resistant behavior of the piles. A comprehensive field/laboratory testing program on weathered rock at the Held test sites was also performed to describe the in situ rock mass conditions quantitatively. And then, the effect of rock mass condition on the load transfer mechanism was investigated. The f-w (side shear resistance-displacement) curve of the pile in moderately weathered rock reached to yielding point at a for millimeter displacements, and after yielding point, the rate of resistance increment dramatically decreased. However, the f-w curve in the highly/completely weathered rock did not show the obvious yielding point, and the resistance gradually increased showing the hyperbolic pattern until relatively high displacement (>15 mm). The q-w (end bearing resistance-displacement) curves showed linear response at least until the base displacement of approximately 10 mm, regardless of rock mass conditions.

Study of Polymer Rapid Setting Cement Concrete Using Electric Arc Furnace Oxidizing Slag Aggregate (전기로(電氣爐) 산화(酸化)슬래그 잔골재를 이용한 폴리머 속경성(速硬性) 시멘트 콘크리트 기초물성(基礎物性) 연구(硏究))

  • Jung, Won-Kyong;Gill, Yong-Soo;Kang, Seung-Hee
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.30-40
    • /
    • 2012
  • Electric arc furnace slag is made in ironworks during steel refining, it is been increasing chemical and physical resistibility using ageing method of unstable state of melting steel slag for using concrete's fine aggregates. Which is been changing stable molecular structure of aggregates, it restrains moving of ion and molecule. In Korea, KS F 4571 has been prepared for using the electric arc furnace oxidizing slag to concrete aggregates(EFS). In this study, Electric arc furnace oxidizing slag is used in the PRCC(Polymer Rapid setting Cement Concrete) which is applied a bridge pavement of rehabilitation, largely. The results showed that the increment of compressive strength development by 10- 20%. The flexural strength of EFS-Con increased greatly as the electric arc furnace oxidizing slag changed. The compressive strength and flexural strength developed enough for opening the overlayed EFS-Con to the traffic after 4 hours of EFS-Con placement. The permeability of EFS-Con was evaluated as negligible due to its very low charge passed. Thus, EFS-Con could be used at repairing or overlaying the concrete at fast-track job sites.

Development of BIM and Augmented Reality-Based Reinforcement Inspection System for Improving Quality Management Efficiency in Railway Infrastructure (철도 인프라 품질관리 효율성 향상을 위한 BIM 기반 AR 철근 점검 시스템 구축)

  • Suk, Chaehyun;Jeong, Yujeong;Jeon, Haein;Yu, Youngsu;Koo, Bonsang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.6
    • /
    • pp.63-65
    • /
    • 2023
  • BIM and AR technologies have been assessed as a means of enhancing productivity within the construction industry, through the provision of effortless access to critical data on site, achieved via the projection of 3D models and associated information onto actual structures. However, most of the previous researches for applying AR technology in construction quality management has been performed for construction projects in general, resulting in only overall on-site management solutions. Also, a few previous researches for the application of AR in the quality management of specific elements like reinforcements focused only on simple projection, so conducting specific quality inspection was impossible. Hence, this study aimed to develop a practically applicable BIM-based AR quality management system targeted for reinforcements. For the development of this system, the reinforcement inspection items on the quality checklist used at railway construction sites were analyzed, and four types of AR functions that can effectively address these items were developed and installed. The validation result of the system for the actual railway bridge showed a degradation of projection stability. This problem was solved through model simplification and enhancement of the AR device's hardware performance, and then the normal operation of the system was validated. Subsequently, the final developed reinforcement quality inspection system was evaluated for practical applicability by on-site quality experts, and the efficiency of inspection would significantly increase when using the AR system compared to the current inspection method for reinforcements.

Fabrication Technique and Structural Performance Verification of PSC U-Type Segment Girder Using On-Site Pretension Method (현장 프리텐션 긴장 방식 적용 PSC U형 분절 거더 제작 기술 및 구조 성능 검증)

  • Sangki Park;Jaehwan Kim;Dong-Woo Seo;Ki-Tae Park;Hyun-Ock Jang
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.17-26
    • /
    • 2023
  • Prestressed Concrete (PSC) girders are divided into pre- and post-tension types as prestressing method, and I- and U-type as cross-sectional shape. There are both advantages and disadvantages depending on each prestressing method and cross-sectional shape, and each method is applied to bridge construction sites. In this study, a new girder design was attempted to develop that overcomes its shortcomings by using the pretension method and U-type cross sectional shape. Its structural performance was verified in this study. Pretension type girders are mainly manufactured in factories because they require a reaction arm and related facilities, and have the disadvantage of being limited in weight and span length for road transportation. In addition, in the case of the U-type cross-section, structural stability is very reliable during construction against overturning, but its own weight is relatively large comparing to I-type, and the post-tension method is mainly applied after on-site production. In this study, a PSC girder manufacturing method using the field pretension was proposed and a span length of 40 m real-scale test specimen was manufactured and verified its structural performance.

Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer (무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석)

  • Lee, Jea-Koo;Kyung, Kee-Sung;Kim, Hak-Nam;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.9 no.1
    • /
    • pp.23-37
    • /
    • 1990
  • In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

  • PDF

Ecological health assessment of Yangjaecheon and Yeouicheon using biotic index and water quality (생물지수와 수질을 이용한 양재천과 여의천의 생태건강성평가)

  • Jin Hyo Lee;Hyeon Han;Jun Yeon Lee;Young Seop Cha;Seog Ju Cho
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.2
    • /
    • pp.172-186
    • /
    • 2022
  • Benthic macroinvertebrates are important ecological and environmental indicators as primary or secondary consumers, and therefore are widely used in the evaluation of aquatic environments. However, there are no comprehensive river ecosystem monitoring surveys that link the major physicochemical water quality items with benthic macroinvertebrates in urban streams. Therefore, this study investigated the distribution characteristics of benthic macroinvertebrates and physicochemical water quality items (17 items) in Yangjaecheon and Yeouicheon from 2019 to 2020. At the same time, by applying Spearman's rank correlation analysis and nonmetric multidimensional scaling (nMDS) analysis in the water quality data and biotic index, we tried to provide basic data for diagnosing the current status of river ecosystems in major urban rivers in Seoul. Based on the study results, a total of 39 species and 3,787 individuals were identified in Yangjaecheon, the water quality(based on BOD, TOC, and TP) of Yangjaecheon was higher than Grade Ib(good), and the BMI using benthic macroinvertebrates appeared as Grade C(normal) at all the sites. In Yeouicheon, a total of 51 species and 4,199 individuals were identified, the water quality(based on BOD, TOC, TP) was higher than Grade Ib(good) similar to Yangjaecheon, and the BMI of both Upstream and Saewon bridge was Grade B(good), while Yeoui bridge was Grade C(normal). Overall, analysis results for the distribution of benthic macroinvertebrates by a nonmetric multidimensional scaling method showed no significant difference between the two streams (p=0.1491). Also, significant environmental variables related to benthic macroinvertebrates distribution were determined as water temperature and DO. On the other hand, the results of the correlation analysis between biotic index and major water quality items confirmed that R1 and BMI could be used for on-site urban river water quality evaluation.

The Abuse and Invention of Tradition from Maintenance Process of Historic Site No.135 Buyeo Gungnamji Pond (사적 제135호 부여 궁남지의 정비과정으로 살펴본 전통의 남용과 발명)

  • Jung, Woo-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.2
    • /
    • pp.26-44
    • /
    • 2017
  • Regarded as Korea's traditional pond, Gungnamj Pond was surmised to be "Gungnamji" due to its geological positioning in the south of Hwajisan (花枝山) and relics of the Gwanbuk-ri (官北里) suspected of being components to the historical records of Muwang (武王)'s pond of The Chronicles of the Three States [三國史記] and Sabi Palace, respectively, yet was subjected to a restoration following a designation to national historic site. This study is focused on the distortion of authenticity identified in the course of the "Gungnamji Pond" restoration and the invention of tradition, whose summarized conclusions are as follows. 1. Once called Maraebangjuk (마래방죽), or Macheonji (馬川池) Pond, Gungnamji Pond was existent in the form of a low-level swamp of vast area encompassing 30,000 pyeong during the Japanese colonial period. Hong, Sa-jun, who played a leading role in the restoration of "Gungnamji Pond," said that even during the 1940s, the remains of the island and stone facilities suspected of being the relics of Gungnamji Pond of the Baekje period were found, and that the traces of forming a royal palace and garden were discovered on top of them. Hong, Sa-jun also expressed an opinion of establishing a parallel between "Gungnamji Pond" and "Maraebangjuk" in connection with a 'tale of Seodong [薯童說話]' in the aftermath of the detached palace of Hwajisan, which ultimately operated as a theoretical ground for the restoration of Gungnamj Pond. Assessing through Hong, Sa-jun's sketch, the form and scale of Maraebangjuk were visible, of which the form was in close proximity to that photographed during the Japanese colonial period. 2. The minimized restoration of Gungnamji Pond faced deterrence for the land redevelopment project implemented in the 1960s, and the remainder of the land size is an attestment. The fundamental problem manifest in the restoration of Gungnamji Pond numerously attempted from 1964 through 1967 was the failure of basing the restorative work in the archaeological facts yet in the perspective of the latest generations, ultimately yielding a replication of Hyangwonji Pond of Gyeongbok Palace. More specifically, the methodologies employed in setting an island and a pavilion within a pond, or bridging an island with a land evidenced as to how Gungnamji Pond was modeled after Hyangwonji Pond of Gyeongbok Palace. Furthermore, Chihyanggyo (醉香橋) Bridge referenced in the designing of the bridge was hardly conceived as a form indigenous to the Joseon Dynasty, whose motivation and idea of the misguided restoration design at the time all the more devaluated Gungnamji Pond. Such an utterly pure replication of the design widely known as an ingredient for the traditional landscape was purposive towards the aesthetic symbolism and preference retained by Gyeongbok Palace, which was intended to entitle Gungnamji Pond to a physical status of the value in par with that of Gyeongbok Palace. 3. For its detachment to the authenticity as a historical site since its origin, Gungnamji Pond represented distortions of the landscape beauty and tradition even through the restorative process. The restorative process for such a historical monument, devoid of constructive use and certain of distortion, maintains extreme intimacy with the nationalistic cultural policy promoted by the Park, Jeong-hee regime through the 1960s and 1970s. In the context of the "manipulated discussions of tradition," the Park's cultural policy transformed the citizens' recollection into an idealized form of the past, further magnifying it at best. Consequently, many of the historical sites emerged as fancy and grand as they possibly could beyond their status quo across the nation, and "Gungnamji Pond" was a victim to this monopolistic government-led cultural policy incrementally sweeping away with new buildings and structures instituted regardless of their original space, and hence, their value.

Change in Water Quality on Upper Stream of Mankyeong River (만경강 상류 지역 수질의 시기별 변화)

  • Moon, Young-Hee;Park, Jong-Min;Son, Jae-Gwon;Kim, Kea-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.252-257
    • /
    • 2001
  • To get the basic information for the water quality improvement and control of water resource at Mankyeong river stream, the water quality in four site of main stream and three site of branch stream at the upper stream were investigated mainly from February to August in 2000. The water temperature was affected by depth, flow rate of the water, and air temperature, and ranged 6.4 to $30.8^{\circ}C$. The pH, DO and BOD values of the water was $5.9{\sim}9.7$, $4.6{\sim}14.50\;mg/L$, and $0.1{\sim}11.8\;mg/L$ range, respectively. The content of total nitrogen, $NO_3-N$ and $NH_4-N$ was $1.19{\sim}10.61\;mg/L$, $1.00{\sim}5.93\;mg/L$, and ND $(non\;detected){\sim}2.79$ mg/L, respectively. The concentration of total phosphorus was ND to 1.14 mg/L. The concentration of Cl ion was $3.5{\sim}196.4\;mg/L$. The content of Fe and Mn was $0.002{\sim}0.100\;mg/L$ and $ND{\sim}0.04\;mg/L$, respectively. The contents of heavy metal Cd, Cu, and Zn were $ND{\sim}0.03\;mg/L$, $ND{\sim}0.05\;mg/L$, and $0.001{\sim}0.17\;mg/L$, respectively. Pb was not detected in all the samples. The pH, total nitrogen contents, and total phosphorus content were frequently exceeded the water quality standard for agriculture. The degree of water pollution was very varied by the sampling place. The water quality was generally polluted in the dry season more than in rainy season. The highest level of water pollution observed in the area of Samyea Bridge among the 7 sites.

  • PDF