• Title/Summary/Keyword: bridge loads

Search Result 717, Processing Time 0.035 seconds

Determination of equivalent blasting load considering millisecond delay effect

  • Song, Zhan-Ping;Li, Shi-Hao;Wang, Jun-Bao;Sun, Zhi-Yuan;Liu, Jing;Chang, Yu-Zhen
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.745-754
    • /
    • 2018
  • In the analysis of the effects of rock tunnel blasting vibration on adjacent existing buildings, the model of simplified equivalent load produces higher calculation result of vibration, due to the lack of consideration of the millisecond delay effect. This paper, based on the static force equivalence principle of blasting load, proposes a new determination method of equivalent load of blasting vibration. The proposed method, based on the elastic-static force equivalence principle of stress wave, equals the blasting loads of several single blastholes in the same section of millisecond blasting to the triangle blasting load curve of the exploded equivalent elastic boundary surface. According to the attenuation law of stress wave, the attenuated equivalent triangle blasting load curve of the equivalent elastic boundary is applied on the tunnel excavation contour surface, obtaining the final applied equivalent load. Taking the millisecond delay time of different sections into account, the time-history curve of equivalent load of the whole section applied on the tunnel excavation contour surface can be obtained. Based on Sailing Tunnel with small spacing on Sanmenxia-Xichuan Expressway, an analysis on the blasting vibration response of the later and early stages of the tunnel construction is carried out through numerical simulation using the proposed equivalent load model considering millisecond delay effect and the simplified equivalent triangle load curve model respectively. The analysis of the numerical results comparing with the field monitoring ones shows that the calculation results obtained from the proposed equivalent load model are closer to the measured ones and more feasible.

Effects of Minimum Horizontal Load on Structural Safety of System Supports (시스템 동바리 구조 안전성에 대한 최소 수평하중의 영향)

  • Chung, Dae Hyun;Kim, Gyeoung Yun;Won, Jeong-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.37-43
    • /
    • 2015
  • This study examined the effects of the minimum horizontal load on the structural behaviors and safety of system supports. The minimum horizontal load was frequently ignored in the design of system supports even though the level of that load was specified in the code and guide in Korea such as 'Standard Specification in Temporary Construction' and 'Guide to Installation of Shores for a Concrete Bridge'. To examine the effects of considering the minimum horizontal load, the finite element analysis were performed for various system supports. By varying installing parameters of system supports such as the vertical member spacing, the installation height, and the thickness of slab, the maximum combined stress ratios were estimated to investigate the structural safety of system supports. The results showed similar axial stress in vertical members but an increase in bending stress with a consideration of the horizontal load. The combines stress ratios are remarkably increased due to the consideration of the horizontal load. Consequently, the system supports, which were initially estimated to be safe when only the vertical loads were considered, were changed to be unsafe in most cases by the effects of the both the vertical and horizontal stresses. Therefore, the minimum horizontal load following the code and the guide is an essential load that could control the structural safety of system supports.

Characteristics of Non-point Pollutants from the Road Runoff (1): Water Quality (도로노면 유출수의 비점오염원 배출 특성(1): 기본 수질 항목)

  • Park, Sangwoo;Oh, Jeill;Choi, Younghwa;Seo, Jeongwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.225-233
    • /
    • 2007
  • Road runoff water is one of the non-point sources (NPSs) of pollution negatively influencing drinking water source. Numerous road runoff NPS waters have been studied for over the last decade. However, the sources of pollution can be conditional, seasonal, or accidental. Therefore, measurement of pollutant loadings in different site is necessary to estimate the effect of road runoff water. The objective of this study was to examine the quality of road runoff water from a city bridge in Seoul, Korea. This study was conducted for two years to assess annual discharge pollution loads. In this study, key water quality parameters including chemical oxygen demand ($COD_{Cr}$), biochemcial oxygen demand ($BOD_5$), total nitrogen (T-N), total phosphorus (T-P), and suspended solid (SS) were measured at 18 different events. The results showed that typically the pollutant concentrations are higher at the beginning of each event and decrease afterwards. The first 20% of the volume of the runoff from each event is transporting 46% ($COD_{Cr}$), 48% ($BOD_5$), 50% (T-N), 34% (T-P), 30% (SS), respectively. The event mean concentrations (EMCs) were $COD_{Cr}$ (199 mg/L), $BOD_5$ (41.2 mg/L), T-N (7.97 mg/L), T-P (0.42 mg/L) and SS (113 mg/L). Although the results were consistent with the previous study (Barbosa and Hvitved-Jacobsen, 1999), $COD_{Cr}$, $BOD_5$, T-N exhibit a stronger first flush effect compared to the other contaminants.

Characteristics of Non-point Pollutants from the Road Runoff (2): Heavy Metals and Pathogens (도로노면 유출수의 비점오염원 배출 특성(2): 중금속 및 병원성 미생물)

  • Park, Sangwoo;Oh, Jeill;Choi, Younghwa;Kim, Jonghwa;Ha, Jaewon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.235-242
    • /
    • 2007
  • Road runoff water includes various heavy metals (zinc, Zn; lead, Pb; copper, Cu; chrome, Cr; cadmium, Cd; etc.) and pathogens (E-coli and coliform). Since these pollutants are significantly harmful to human beings and have negative impact on water streams, numerous studies have been conducted to determine the characterization of these non-point pollutants from road runoff water. However, since these non-point pollutant concentrations vary depending on road traffic, road construction, and road maintenance, measurement of pollutant loadings in different site is necessary to estimate the effect of road runoff water on drinking water source. The objective of this study was to examine the quality of road runoff water from a city bridge in Seoul, Korea. This study was conducted for two years to assess annual discharge pollution loads. In this study, five key heavy metals (Zn, Pb, Cu, Cr, and Cd) and two pathogens (E-coli and coliform) were measured at 18 different events. The pollutant load mass transported was always higher than the corresponding runoff volume for Zn, Cu, and Cd, while Pb and Cr showed similar values between the load mass transported and the corresponding runoff volume. The event mean concentrations were Zn (0.908 mg/L), Pb (0.092 mg/L), Cu (0.141 mg/L), Cr (0.023 mg/L), and Cd (0.006 mg/L). Like Zn, Cu, and Cd, E-coli and coliform values (relatively high in Summer and Fall) are higher at the beginning of each event and decrease afterwards.

The Pseudo-Dynamic Test for the Seismic Retrofit System Utilizing Existing Bridge Bearings (교량의 기존 받침을 활용하는 내진보강시스템의 유사동적 실험)

  • Kwahk, Im-Jong;Cho, Chang-Beck;Kim, Young-Jin;Kwark, Jong-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.21-27
    • /
    • 2007
  • In this study, an approach that installs seismic isolation bearings was proposed for the seismic retrofit of the existing bridges. The method that replaces all existing bearings with seismic isolators was proposed already. However, in this study, we recommend to utilize the existing bearings for the benefit of safety and cost. According to our proposal, the seismic isolators do not support vertical loads but they Just function as the period shifter and the horizontal damper. To verify this approach experimentally, the real scale bearings and lead rubber bearings far the real highway bridges were designed and fabricated. And the responses of this isolated bridges to the assumed earthquakes were determined by the pseudo dynamic test scheme. The test results were also compared to the responses computed by the well known structural analysis software to check the reliability of the test. From the test results, we found that the retrofitted bridges using the proposed method showed stable performances under earthquakes.

A Study on the Dynamic Response of Highway Bridges by 4-Axles Single Truck (4축 단일차량에 의한 도로교의 동적응답에 관한 연구)

  • Chung, Tae-Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.397-404
    • /
    • 2011
  • In this paper, a research for the dynamic wheel loads of a 3D vehicle model, which relates to a tire-enveloping model, is carried out. A single truck with four axles is modeled as a 10-D.O.F. vehicle by modeling both contact length of tires and pitching of tandem spring axles. The dynamic equations of the vehicle are obtained using the Lagrange's equation, the solution of the equations is calculated by Newmark-${\beta}$ method. The validity of the developed 3D vehicle model is demonstrated by comparing results obtained from the proposed method with those from experimental data. The maximum impact factors of tire force are evaluated according to the various step bumps on which a 24-ton dump truck is running.

Deflection Analysis of Long Span Structures Using Under-Tension System (언더텐션 시스템을 이용한 장스팬 구조의 처짐 거동 해석)

  • Park, Duk-Kun;Lee, Jin;Ham, Su-Yun;Ahn, Nam-Shik;Lee, Ki-Hak;Lee, Jae-Hong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.66-69
    • /
    • 2008
  • This study presents deflection analysis of long span structures for pedestrian bridge on crossroads. For long span structures, the size of structural members should be determined considering the esthetic view and vehicle below the structures. As a result, the slenderness ratio of members is increased and the structure may be suffered from significant deflection. The under-tensioned system on lower part of the structure, is applied in order to reduce the deflection and the size of members. In this regard, the under-tensioned system enables the load of upper parts to carη to the end of beam by means of tensional force in cable. In addition, effectiveness of under-tensioned system can be different depending on the size of cable, the number and spacing of posts. This study is performed with conforming the effect by analytical various parameters (size of cable, number and spacing of post). Dead and live loads is supposed to apply in the slab, and the analytical result by MIDAS program are presented addressing the effect of the under-tensioned system.

  • PDF

Design and Implementation of a Bidirectional Power Supply Charger Using Super Capacitors and Solar Panel for Robot Cleaner Applications (슈퍼 커패시터 및 태양전지를 이용한 로봇청소기용 양방향 충전시스템 설계)

  • Zheng, Tao;Piao, Sheng-Xu;Kwon, Dae-Hwan;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.97-102
    • /
    • 2016
  • In this paper, a bidirectional power supply charger is proposed. This system used a solar cell panel to generate electricity and used super capacitors to store these energies, which can be used for the robot cleaner or some other electronic products. This system include a phase-shift controlled bidirectional dual active bridge (DAB) converter, solar panel super capacitors and DSP controller. In the daytime it can charge to the super capacitors to store the energy generated by the solar cell panel and in the night it will release the energy stored in the super capacitors to loads. A prototype of the proposed bidirectional power supply charger system was designed which can achieve 18V to 30V input, 10V/20W output to super capacitors and 9V/6.5W output when it acts as a charger for the robot cleaner. The system is verified to be sTable and reliable by both the simulation and experimental results.

An Experimental Study on Thermal Prestressing Method for Strengthening Concrete Bridge (콘크리트 교량의 보강을 위한 온도 프리스트레싱 공법의 실험적 연구)

  • Ahn, Jin-Hee;Kim, Jun-Hwan;Choi, Kyu-Tae;Kim, Sang-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2007
  • Traditional external post-tensioning method using either steel bars or tendons is commonly used as a retrofitting method for concrete bridges. However, the external post-tensioning method has some disadvantages such as stress concentration at anchorages and inefficient load carrying capability regarding live loads. Thermal prestressing method is a newly proposed method for strengthening and rehabilitation of concrete girder bridges. Founded on a simple concept of thermal expansion and contraction of steel, the method is a hybrid method of external post-tensioning and steel plate bonding, combining the merits of two methods. In this paper, basic concepts of the method are presented and an illustrative experiment is introduced. From actual experimental data, the thermal prestressing effect is substantiated and the FEM approach for its analysis is verified.

Design of Six-Component F/T Sensor with Flexible Fixed Ends (유연한 고정단을 가진 6축 F/T 센서의 설계)

  • Lee, Bong-Hee;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.771-780
    • /
    • 2010
  • This paper describes the design process of a six-component force/torque (F/T) sensor. The new six-component F/T sensor having leaf spring ends has been developed using a cross beam structure as the basic sensing element. Fundamental strain analysis of both ends fixed beam having a leaf spring structure is performed by finite element analysis. In order to obtain similar output sensing strains from the six component loads and minimize coupling strains, the optimal location of strain gages is determined and the strain gages are connected so that the bridge circuits with four strain gages would be balanced. Using leaf spring ends instead of rigid fixed ends, remarkable increment in output sensing strain can be achieved for two component forces. Several modifications in design result in a similar sensing strain of approximately $400\;{\mu}m/m$ for the six-component forces and moments, and a reduced coupling strain of $0\;{\mu}m/m$ between the forces and moments.