• Title/Summary/Keyword: branch-line

Search Result 391, Processing Time 0.023 seconds

Design and Manufacture of Triple-Band Antennas with Two Branch Line and a Vertical Line for WLAN/WiMAX system applications (2개 분기선로와 수직 선로를 갖는 WLAN/WiMAX 시스템에 적용 가능한 삼중대역 안테나 설계 및 제작)

  • Choi, Tae-Il;Yoon, Joong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.740-747
    • /
    • 2019
  • In this paper, an antenna applicable to WLAN and WiMAX frequency bands is designed, fabricated, and measured. The proposed antenna is designed to have two branch strip line in the patch plane and a rectangular slit in the ground plane based on microstrip feeding for triple band characteristics and added a vertical strip in the ground plane to enhance impedance bandwidth characteristics. The proposed antenna is designed on a substrate with a relative permittivity of 4.4, a thickness of 1.0 mm, and has a size of $18.0mm(W1){\times}37.3mm$ (L4+L5+L7). From the fabricated and measured results, impedance bandwidths of 480 MHz (2.32 to 2.80 GHz) for 2.4/2.5 GHz band, 810 MHz (3.22 to 4.03 GHz) for 3.5 GHz band, and 1,820 MHz (5.05 to 6.87 GHz) for 5.0 GHz band were obtained based on the impedance bandwidth. Measured 3D pattern and gains are displayed.

A Study on Design Area of Fire Sprinkler System (스프링클러설비의 설계면적에 대한 연구)

  • Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.93-98
    • /
    • 2010
  • Even though the sprinkler system is a essential fire suppression system, the design engineers do not fully understand the concept of design area which sprinklers operate. They frequently made a mistake to form design area and calculate it. The shape of design area is a square or a rectangle which branch side line is a little longer than the cross main side. NFPA demands to lengthen the branch side to 1.2 times than the cross main side and FM demands 1.4 times. The longer the branch side at the same design area is, the bigger the water quantity and pressure is. At the results of hydraulic calculation of design areas, when the branch side is longer 1.2 times, the water quantity became 4.6% bigger than exact square and the pressure came to 4.67% bigger. When it is longer 1.4 times, the water quantity and the pressure are bigger 7.52%, 14.51%. Therefore, the sprinkler design engineers should follow the general rule of design area, exact square or rectangle which length along the branch line is a little longer than length along the cross main, to design more stable system.

Monitoring changes in the genetic structure of Brown Tsaiya duck selected for feeding efficiency by microsatellite markers

  • Yi-Ying Chang;Hsiu-Chou Liu;Chih-Feng Chen
    • Animal Bioscience
    • /
    • v.36 no.3
    • /
    • pp.417-428
    • /
    • 2023
  • Objective: Few studies have genetically monitored chickens over time, and no research has been conducted on ducks. To ensure the sustainable management of key duck breeds, we used microsatellite markers to monitor Brown Tsaiya ducks over time genetically. Methods: The second, fourth, sixth to eighth generations of the Brown Tsaiya duck selected for feeding efficiency and control lines were included in this study to investigate the genetic variations, effective population size, population structure and the differentiation between populations over time with 11 microsatellite markers derived from Brown Tsaiya duck. Results: The results showed there were a slight decrease in the genetic variations and an increase in within-population inbreeding coefficient (FIS) in both lines, but no consistent increase in FIS was observed in each line. The effective population size in the second and eighth generations was 27.2 for the selected line and 23.9 for the control line. The change in allele richness showed a downward trend over time, and the selected line was slightly lower than the control line in each generation. The number of private alleles (Np) in the selected line were higher than in the control line. Moderate differentiation was observed between the second and eighth generations in the selected line (FST = 0.0510) and the control line (FST = 0.0606). Overall, differentiation tended to increase with each generation, but genetic variation and structure did not change considerably after six generations in the two lines. Conclusion: This study provides a reference for poultry conservation and helps to implement cross-generation genetic monitoring and breeding plans in other duck breeds or lines to promote sustainable management.

A Study on the Out Flow Characteristics of Non-Point Source Pollution in the Branch River of So-yang Lake (소양호 지류하천의 비점오염원 유출특성에 관한 연구)

  • Choi, Han-Kuy;Choi, Chang-Ho;Park, Soo-Jin
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.199-205
    • /
    • 2009
  • This study selected Naerin Stream, Inbuk Stream and Buk Stream, branch rivers of Soyang Dam, also area of highland agriculture as test sites and measured flow and water quality, particularly eutrophication factors (BOD, COD, T-N, and T-P) in precipitation season and non precipitation season for a year, 2008. Based on the result, the study examined the change in water quality in relation to flow, and created flow discharged - pollution loads regression line by estimating pollution loads flowed from each branch river. And the study calculated annual pollution discharge loads for unit area and proposed regression equation on it by using regression analysis.

  • PDF

산화제 공급배관의 분기 위치에 따른 추진기관 성능 비교

  • Kim, Ji-Hoon;Lee, Han-Ju;Jung, Dong-Ho;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.179-185
    • /
    • 2005
  • It is an essential subject to decrease the mass of a launch vehicle for improving performance and efficiency of space launch system. Particularly, reducing the engine supporting area is necessary for high efficiency of propulsion system with clustered engine systems. The engine supporting area is related to the branch location of the oxidizer feeding line. This article deals the performance variation of the propulsion system such as the mass of the oxidizer feeding line, pressurization pressure of the oxidizer tank, and the onset of nucleation boiling in the oxidizer pipe with the branch location of the main feeding line.

  • PDF

Integer Programming Approach to Line Optimization of Multiple Surface Mounters (정수계획법에 의한 다수 표면실장기의 라인 최적화)

  • Kim Kyung-Min;Park Tae-Hyoung
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.46-54
    • /
    • 2006
  • We propose an optimization method for PCB assembly lines including multiple surface mounters. To increase the productivity of PCB assembly line, the component allocation, feeder assignment, and assembly sequence of each surface mounter should be optimized. The optimization Problem is formulated as an integer programming problem. We divide the overall problem into two hierarchical sub-problems: forward-path problem and backward-path problem. The clustering algorithm and branch-and-bound algorithm are applied to solve the forward-path problem. The assignment algorithm and connection algorithm are applied to solve the backward-path problem. Simulation results are presented to verify the usefulness of the proposed method.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Evaluation of Genetic Heterogeniety among the Corn Landraces Collected from Farmer's Field

  • Kim, In-Jong;Min, Hwang-Kee;Park, Jong-Yeol;Choi, Ik-Young;Kim, Nam-Soo
    • Plant Resources
    • /
    • v.1 no.1
    • /
    • pp.26-32
    • /
    • 1998
  • This paper describes the variations in eight agronomic traits in three unadapted local landraces and an inbred cultivar of corn. To compare the agronomic traits in field evaluation with molecular marker evaluation the genotypes of the plant introduction were also checked by 4 microsatellite-SSR loci. The variations of the eight agronomic traits were higher in the local landrades than in the inbred line. which was substantiated by the high genetic variation in the landrades with microsatellite-SSR loci. The level of genetic variation was also different between landraces. Since the genetic evaluation can be easily quantified by the analysis of microsatellite-SSR loci. the threshold level of genetic homogeneity in the population for parental lines in breeding program can be determined and the effort of maintaining the landrace population would be alleviated. As an example in our analysis. the entry from Whachon should not need the same number of selfing generations as the other two landraces to get the level of inbred state. Since this line showed lowest intra-genetic variation within the population.

  • PDF

Real-Time Expert System With Loss Reduction And Load Balancing (손실감소와 부하균등지수를 고려한 실시간 전문가 시스템)

  • Kim, Jung-Nyun;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1097-1099
    • /
    • 1998
  • This paper describes methods to quickly reconfigure the branch in a distribution system by using tie-line switches without branch overloading and feeder overloading, voltage in load points, and distribution system is represented by object-based structure to search efficiently.

  • PDF