• Title/Summary/Keyword: brain recording

Search Result 93, Processing Time 0.027 seconds

Quantitative analysis of oculomotor system by automatic identification algorithm (자동판별 알고리즘에 의한 동안계의 정량적인 해석)

  • 장인호;이세현;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.637-640
    • /
    • 1986
  • The design and use of a micro-computer-based system for quantitative study of ocular kinetics are described. An algorithm for microcomputer analysis of electro-oculographically recorded saccadic eye movement is presented. From a brief, 4-min recording session detailed statistical information about saccade amplitude, duration, and velocity can be obtained. Since this data is not significantly altered by practice of motivational factors, it provides a sensitive functional test of the oculomotor system and its brain control system.

  • PDF

Improved Feature Extraction of Hand Movement EEG Signals based on Independent Component Analysis and Spatial Filter

  • Nguyen, Thanh Ha;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.515-520
    • /
    • 2012
  • In brain computer interface (BCI) system, the most important part is classification of human thoughts in order to translate into commands. The more accuracy result in classification the system gets, the more effective BCI system is. To increase the quality of BCI system, we proposed to reduce noise and artifact from the recording data to analyzing data. We used auditory stimuli instead of visual ones to eliminate the eye movement, unwanted visual activation, gaze control. We applied independent component analysis (ICA) algorithm to purify the sources which constructed the raw signals. One of the most famous spatial filter in BCI context is common spatial patterns (CSP), which maximize one class while minimize the other by using covariance matrix. ICA and CSP also do the filter job, as a raw filter and refinement, which increase the classification result of linear discriminant analysis (LDA).

A Study on the Development of Integrated Chaos Analysis System for EEG (뇌파신호의 카오스 특징 추출을 위한 통합 시스템의 개발)

  • Woo, Yong-Ho;Kim, Hyun-Sool;Kim, Taek-Soo;Choi, Yoon-Ho;Park, Sang-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.962-964
    • /
    • 1995
  • In this paper, an integrated chaos analysis system for EEG (ICASE) is designed for the analysis of brain functions based on the chaos theory. Nonlinear dynamic characteristics of EEG such as 3-D attractor, Poincare section, correlation dimension, Lyapunov exponents and power spectrum are extracted by this system. The results show that chaotic attractors which indicate the presence of deterministic, dynamics of complex nature could be identified from a routine EEG recording for normal and pathological activity. This proves that the chaotic analysis of EEG may be an appropriate tool in the classification of brain activity and thus a possible diagnostic tool.

  • PDF

Difference of Neuronal Recovery by Incubation Condition after Transient Hypoxia (배양조건에 의한 일과성 저산소상태 후 신경세포회복의 차이)

  • Moon, Soo-Hyeon;Oh, Jae-Inn;Park, Youn-Kwan;Chung, Heung-Sub;Lee, Hoon-Kap;Lee, Ki-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1161-1170
    • /
    • 2000
  • Objective : The transverse hippocampal slice is one of the most commonly studied in vitro models of mammalian brain physiology. However, despite its broad usage, there has been no standardization of slice preparation techniques or recording condition. It is well known that variations in recording conditions can result in profound different effects to neuronal responses. Evoked field potentials, recorded extracellularly, were used to investigate the effects of variations in hippocampal slice preparation protocol on hypoxia responses of CA1 neurones. Material & Methods : Before hypoxic injury, hippocampal slices were incubated for 4 hours. During incubation period, the slices were placed in a incubation chamber($21^{\circ}C$) for recovery from preparation injury and then transferred to recording chamber($34^{\circ}C$) for more recovery and baseline electric recording with current stimulation(0.1Hz). Various time periods in incubation chamber and recording chamber were applied to each experimental group(group 1=60min : 180min, group 2=90min : 150min, group 3=180min : 60min, time in incubation chamber : time in recording chamber) before 10 min hypoxia produced by replacing 95% $O_2$+5% $CO_2$ mixed gas to 95% $N_2$+5% $CO_2$ gas. Calcium, Magnesium ions and several drugs effecting on glutamate receptor also were studied. Recoveries from hypoxic injury of hippocampal slices were estimated by percent recovery of population spike(PS). Statistic analysis of study were performed using paired t-test. Results : The percent recovery of PS after 10min hypoxia was considerably enhanced by increasing the period of current stimulation during incubation period before hypoxic injury. Temperature effect on the result of this experiment was also studied(group 4) but the result from this showed no statistic significance. Low magnesium ion concentration of artificial CSF(Mg-free aCSF) during incubation period enhanced the recovery of PS but low calcium (calcium-free) and high magnesium ion concentration(2mM) reduced it after hypoxic injury. L-glutamate($100{\mu}M$) and AP-5($50{\mu}M$) had no effect on the recovery of PS but CNQX($10{\mu}M$) in artificial CSF during incubation period markedly enhanced the recovery of PS. Co-treatment of AP-5($50{\mu}M$), CNQX($10{\mu}M$) and high magnesium concentration(2mM) enhanced recovery of PS in immediate following period of hypoxic injury but the effect of cotreatment after then decayed rapidly and lost statistic significance. Conclusions : Judging from above results, the condition of baseline recording is important in observing the recovery of population spike after hypoxia, and the time and the condition should be controled more strictly to obtain reliable results.

  • PDF

Interval estimate of physiological fluctuation of peak latency of ERP waveform based on a limited number of single sweep records

  • Nishida, Shigeto;Nakamura, Masatoshi;Suwazono, Shugo;Honda, Manabu;Nagamine, Takashi;Shibasaki, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.1.1-5
    • /
    • 1994
  • In the single sweep record of event-related potential (ERP), the peak latency of P300, which is one of the most prominent positive peaks in the ERP record, might fluctuate according to the recording conditions. The fluctuation of the peak latency (measurement fluctuation) is the summation of the fluctuation caused by physiological factor (physiological fluctuation) and one by noise of background EEG (noise fluctuation). We propsed a method for estimating the interval of the physiological fluctuation based on a limited number of single sweep records. The noise fluctuation was estimated by using the relationship between the signal-to-noise (SN) ratio and the noise fluctuation based on the P300 model and the background EEG model. The interval estimate of the physiological fluctuation were obtained by subtracting the interval estimate of the noise fluctuation from that of the measurement fluctuation. The proposed method was tested by using simulation data of ERP and applied to actual ERP and data of normal subjects, and gave satisfactory results.

  • PDF

NMDA Receptor-dependent Inhibition of Synaptic Transmission by Acute Ethanol Treatment in Rat Corticostriatal Slices

  • Choi, Se-Joon;Kim, Ki-Jung;Choi, Hyeong-Seok;Kim, Seong-Yun;Yim, Dong-Seok;Cho, Young-Jin;Hahn, Sang-June;Sung, Ki-Wug
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.6
    • /
    • pp.303-307
    • /
    • 2006
  • The effects of ethanol on corticostriatal synaptic transmission were examined, using extracellular recording and analysis of population spike amplitudes in rat brain slices, to study how acute ethanol intoxication impairs striatal function. Ethanol caused a decrease in population spike amplitudes in a dose dependent manner ($50{\sim}200mM$). Pretreatment with picrotoxin, a ${\gamma}-amino$ butyric acid $(GABA)_{A}$ receptor antagonist, increased the population spikes but ethanol (100 mM) was still effective in decreasing the population spikes under this condition. In the presence of $_{(DL)}-2-amino-5-phosphonovaleric$ acid (APV), N-methyl-D-aspartate (NMDA) receptor antagonist, the inhibitory action of ethanol on population spikes was not shown. These results suggest that ethanol inhibits the glutamatergic corticostriatal synaptic transmission through blockade of NMDA receptors.

Electroencephalography (EEG) based Toxicity Test of Algae Organic Matter on Zebrafish (조류기인 유기물질의 제브라피쉬에 대한 뇌파측정기반 독성평가)

  • Oh Sehyun;Jang hyeongjun;Cho Yunchul
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.3
    • /
    • pp.223-230
    • /
    • 2023
  • Harmful algae blooms have become a serious environmental problem in major river basins in Korea. They are known to produce various algal organic matters (AOMs) including intracellular organic matters (IOMs) and extracellular organic matters (EOMs). Generally AOMs cannot be easily removed by coagulation/flocculation process in conventional drinking water plants. AOMs produced by blue-green algae also include various toxins such as Microcystins, Anatoxin-a, and Saxitoxin known to have harmful effects on living organisms in aquatic environment. In this study, toxic effects of EOMs produced by three different algae species (Microcystis sp., Anabaena sp., and Oscillatoria sp.) on zebrafish were investigated using electroencephalography (EEG) recording method, a technology for recording brain activity. Electroencephalographic changes in zebrafish revealed that a low EOM had a negative effect on zebrafish compared to both Anabaena sp. and Oscillatoria sp. at 30 ppm EOM exposures. This result might be due to Microcystins present in EOMs produced by Microcystis sp. As a result of power spectrum density anallysis, exposure to EOMs produced by Microcystis sp. caused a state of vigilance in zebrafish. This EEG based toxicity test can be used to examine effects of harmful materials at low levels on living organisms in an aquatic system.

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

Research on development of electroencephalography Measurement and Processing system (뇌전도 측정 및 처리 시스템 개발에 관한 연구)

  • Doo-hyun Lee;Yu-jun Oh;Jin-hee Hong;Jun-su chae;Young-gyu Choi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.38-46
    • /
    • 2024
  • In general, EEG signal analysis has been the subject of several studies due to its ability to provide an objective mode of recording brain stimulation, which is widely used in brain-computer interface research with applications in medical diagnosis and rehabilitation engineering. In this study, we developed EEG reception hardware to measure electroencephalograms and implemented a processing system, classifying it into server and data processing. It was conducted as an intermediate-stage research on the implementation of a brain-computer interface using electroencephalograms, and was implemented in the form of predicting the user's arm movements according to measured electroencephalogram data. Electroencephalogram measurements were performed using input from four electrodes through an analog-to-digital converter. After sending this to the server through a communication process, we designed and implemented a system flow in which the server classifies the electroencephalogram input using a convolutional neural network model and displays the results on the user terminal.

Gut Microbial Metabolites Induce Changes in Circadian Oscillation of Clock Gene Expression in the Mouse Embryonic Fibroblasts

  • Ku, Kyojin;Park, Inah;Kim, Doyeon;Kim, Jeongah;Jang, Sangwon;Choi, Mijung;Choe, Han Kyoung;Kim, Kyungjin
    • Molecules and Cells
    • /
    • v.43 no.3
    • /
    • pp.276-285
    • /
    • 2020
  • Circadian rhythm is an endogenous oscillation of about 24-h period in many physiological processes and behaviors. This daily oscillation is maintained by the molecular clock machinery with transcriptional-translational feedback loops mediated by clock genes including Period2 (Per2) and Bmal1. Recently, it was revealed that gut microbiome exerts a significant impact on the circadian physiology and behavior of its host; however, the mechanism through which it regulates the molecular clock has remained elusive. 3-(4-hydroxyphenyl)propionic acid (4-OH-PPA) and 3-phenylpropionic acid (PPA) are major metabolites exclusively produced by Clostridium sporogenes and may function as unique chemical messengers communicating with its host. In the present study, we examined if two C. sporogenes-derived metabolites can modulate the oscillation of mammalian molecular clock. Interestingly, 4-OH-PPA and PPA increased the amplitude of both PER2 and Bmal1 oscillation in a dose-dependent manner following their administration immediately after the nadir or the peak of their rhythm. The phase of PER2 oscillation responded differently depending on the mode of administration of the metabolites. In addition, using an organotypic slice culture ex vivo, treatment with 4-OH-PPA increased the amplitude and lengthened the period of PER2 oscillation in the suprachiasmatic nucleus and other tissues. In summary, two C. sporogenes-derived metabolites are involved in the regulation of circadian oscillation of Per2 and Bmal1 clock genes in the host's peripheral and central clock machineries.