• Title/Summary/Keyword: brain holder

Search Result 6, Processing Time 0.02 seconds

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Complex Permittivity Measurement of Simulated Brain Tissue for the Evaluation of Specific Absorption Rate(SAR) (전자파 비흡수율(SAR) 측정용 인체 두뇌 모의 용액의 복소 비유전율 측정)

  • 김정호;김윤명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.310-313
    • /
    • 2003
  • Complex permittivities of human head simulating liquids were measured by a sample holder of terminated slotted coaxial line with a movable probe at mobile communication frequencies. The validity of the liquid measurement system was checked by experiments with the reference liquids. Liquids of ingredients for human brain suggested in IEEE draft and those made by the authors were measured by this slotted line system.

  • PDF

A Simultaneous NIRS-EEG Study of Seizure in the Mouse Brain

  • Lee, Seung-Duk;Lee, Min-Ah;Koh, Dalk-Won;Kim, Beop-Min;Choi, Jee-Hyun
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.159-160
    • /
    • 2008
  • We measured hemodynamic responses of seizure in the mouse brain using frequencydomain near infrared spectroscopy (NIRS) and electroencephalogram (EEG). We adapted microfabricated optical holder for consistent contact of the optical fiber to the mouse brain. Our results show that the cerebral oxygenation and hemodynamics of mice can be stably monitored with EEG in the mouse brain.

  • PDF

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

An Improved Method for EM Radioautographic Techniques using Cork (EM Radioautographic Techniques에 관(關)한 연구(硏究) - Cork 방법(方法) -)

  • Kim, Myung-Kook;Hassler, R.
    • Applied Microscopy
    • /
    • v.10 no.1_2
    • /
    • pp.7-17
    • /
    • 1980
  • Electron microscope radioautography introduced by Liquier-Milward (1956) is now used routinely in many laboratories. Most of the technical difficulties in specimen preparation have been overcome. This method is modified from loop method for improvement of EM radioautographic techniques. The advantages of this method are: 1. the use of single specimens on small corks and of a large wire loop, allows the experimenter to avoid the blemishes in the membrane; 2. the surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4, thus greatly prolonging the period of time over which good emulsion layers can be made; 3. corks can be handled in perspex holder which allows about 20 specimens to be developed simultaneously. The steps of the method comprise: 1. Cut ribbons of ultrathin sections of silver interference colour 2. Pick them up on formvar-coated 200 mesh grids 3. Prestaining of tissues 4. Coat the specimens with a thin layer of carbon by evaporation (30-60A) 5. Mount the specimens on corks (about 1cm apical diameter) using double-sided scotch tape 6. Emulsion coating; a. Take a 250m1 beaker, place it on the pan of a sliding weight balance and weigh it. Add 10 grams extra to the beam. Add pieces of ILford L4 emulsion to the beaker until the balance is swinging freely. Add the 20ml of distilled water that was previously measured out. b. Surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4. 7. Prepare a series of membranes of gelled emulsion with the wire loop and apply one to each cork-borne specimen. 8. Put the specimens away to expose by pushing the corks into short length of PVC tubing, each tube having a small hole in the side 9. Place the tubes in small boxes together with silica gel. 10. Exposure 11. Developer - Kodak Microdol X for 3 minutes 12. Fixer - A perspex holder can be manufactured which allows 20 specimens to be developed simultaneously. 12. Fixer - 30% sodium thiosulfate for 10 minutes 13. Examination with Siemens Elmiskop 1A electron microscope

  • PDF

The impact of functional brain change by transcranial direct current stimulation effects concerning circadian rhythm and chronotype (일주기 리듬과 일주기 유형이 경두개 직류전기자극에 의한 뇌기능 변화에 미치는 영향 탐색)

  • Jung, Dawoon;Yoo, Soomin;Lee, Hyunsoo;Han, Sanghoon
    • Korean Journal of Cognitive Science
    • /
    • v.33 no.1
    • /
    • pp.51-75
    • /
    • 2022
  • Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation that is able to alter neuronal activity in particular brain regions. Many studies have researched how tDCS modulates neuronal activity and reorganizes neural networks. However it is difficult to conclude the effect of brain stimulation because the studies are heterogeneous with respect to the stimulation parameter as well as individual difference. It is not fully in agreement with the effects of brain stimulation. In particular few studies have researched the reason of variability of brain stimulation in response to time so far. The study investigated individual variability of brain stimulation based on circadian rhythm and chronotype. Participants were divided into two groups which are morning type and evening type. The experiment was conducted by Zoom meeting which is video meeting programs. Participants were sent experiment tool which are Muse(EEG device), tdcs device, cell phone and cell phone holder after manuals for experimental equipment were explained. Participants were required to make a phone in frount of a camera so that experimenter can monitor online EEG data. Two participants who was difficult to use experimental devices experimented in a laboratory setting where experimenter set up devices. For all participants the accuracy of 98% was achieved by SVM using leave one out cross validation in classification in the the effects of morning stimulation and the evening stimulation. For morning type, the accuracy of 92% and 96% was achieved in classification in the morning stimulation and the evening stimulation. For evening type, it was 94% accuracy in classification for the effect of brain stimulation in the morning and the evening. Feature importance was different both in classification in the morning stimulation and the evening stimulation for morning type and evening type. Results indicated that the effect of brain stimulation can be explained with brain state and trait. Our study results noted that the tDCS protocol for target state is manipulated by individual differences as well as target state.