• Title/Summary/Keyword: boundary zone method

Search Result 186, Processing Time 0.029 seconds

Influence of Testing Method on the Fracture Toughness of Cordierite-SiC Whisker Ceramic Composites (코디어라이트-SiC위스커 복합재료에서 측정방법에 따른 파괴인성치의 변화)

  • ;Weisskopf
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.313-320
    • /
    • 1987
  • Fracture toughness of hot pressed cordierite-SiC whisker ceramic composites contained up to 40vol.% SiC whiskers were determined by using the indentation crack length(IC), indentation strengthin-bending(IS), and single-edge notched-beam(SENB) methods. The results were compared to stress intensity factor, KB, at the crack branching boundary measured by using the mirror zone radius (MZ) method. IS method seems to provide a more reasonable estimation of fracture toughness than other methods for these composites.

  • PDF

Effects of Nb Content and Thermal History on the Mechanical and Corrosion Characteristics of Stainless Steels

  • Choe, Han-Cheol;Kim, Kwan-Hyu
    • Corrosion Science and Technology
    • /
    • v.2 no.3
    • /
    • pp.117-126
    • /
    • 2003
  • Due to excellent corrosion resistance and mechanical properties, austenitic stainless steel is widely used as the material for chemical plants. nuclear power plants, and food processing facilities. But, the zone affected by heat in the range of 400 to $800^{\circ}C$ during welding loses corrosion resistance and tensile strength since Cr-carbide precipitation like $Cr_{23}C_6$ forms at the grain boundary and thereby takes place the intergranular corrosion. In this study, AISI 304 stainless steel with the added Nb of 0.3 to 0.7 wt% was solutionized at $1050^{\circ}C$ and sensitized at $650^{\circ}C$. Specimen was welded by MIG. The phase and the microstructure of the specimens were examined by an optical microscope, a scanning electron microscope, and a x-ray diffractometer. The corrosion characteristics of specimens were tested by electrolytic etching and by double loop electrochemical potentiokinetic reactivation method(EPR) in the mixed solution of 0.5M $H_2SO_4$ + 0.01M KSCN. The melting zone had dendritic structure constituted of austenitic phase and $\delta$-ferrite phase. Cr carbide at the matrix did not appear, as Nb content increased. At the grain boundaries of the heat affected zone, the precipitates decreased and the twins appeared. The hardness increased, as Nb content increased. The hardness was highest in the order of the heat affected zone>melted zone>matrix. According to EPR curve, as the Nb content decreased, the reactivation current density(Ir) and the activation current density(la) were highest in the order of the melted zone

Forward and Back Diffusion from Low Permeability Zone: A Review of Analytical Solutions with Different Boundary Conditions (저투수성 매체 내 오염물질의 정확산과 역확산: 경계조건에 따른 용질이동 해석해의 소개)

  • Kim, Changmin;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.99-110
    • /
    • 2020
  • It is a global trend to consider contaminated low-permeability zones as one of the primary management targets for the remediation of DNAPL contaminated sites. In addition, studies on the persistence caused by back diffusion of DNAPLs from low-permeability zones have been actively conducted worldwide. On the other hand, the studies for domestic groundwater contamination with the low-permeability zones are insufficient. Therefore, this study introduces the forward and back diffusions of DNAPL through low-permeability zones and suggests the importance of them by reviewing representative previous studies, especially on back diffusion and plume persistence. We proposed six diffusion scenarios and analytical solutions based on various boundary conditions of low-permeability zones. FI (forward diffusion into infinite domain) and BI (back diffusion form infinite domain) scenarios illustrate forward and back diffusion in which the depths of a low-permeability layer are assumed to be infinite. FFN (forward diffusion into finite domain with no flux boundary) and BFN (back diffusion from finite domain with no flux boundary) scenarios describe forward and back diffusion for a finite domain of a low-permeability layer with no flux boundary at the bottom. When the bottom of a low-permeability layer is considered as flux boundary, forward and back diffusion scenarios correspond to FFF (forward diffusion into finite domain with flux boundary) and BFF (back diffusion from finite domain with flux boundary). The scenarios and analytical solutions in this study may contribute to the determination of an efficient remediation method based on site characteristics such as a thickness of low-permeability zones or duration of contamination exposure.

The effect of infill walls on the seismic behavior of boundary columns in RC frames

  • Fenerci, Aksel;Binici, Baris;Ezzatfar, Pourang;Canbay, Erdem;Ozcebe, Guney
    • Earthquakes and Structures
    • /
    • v.10 no.3
    • /
    • pp.539-562
    • /
    • 2016
  • The seismic behavior of a ${\frac{1}{2}}$ scaled, three-story three-bay RC frame with masonry infill walls was studied experimentally and numerically. Pseudo-dynamic test results showed that despite following the column design provisions of modern seismic codes and neglecting the presence of infill walls, shear induced damage is unavoidable in the boundary columns. A finite element model was validated by using the results of available one-story one-bay frame tests in the literature. Simulations of the examined test frame demonstrated that boundary columns are subjected to shear demands in excess of their shear capacity. Seismic assessment of the test frame was conducted by using ASCE/SEI 41-06 (2006) guidelines and the obtained results were compared with the damage observed during experiment. ASCE/SEI 41-06 method for the assessment of boundary columns was found unsatisfactory in estimating the observed damage. Damage estimations were improved when the strain limits were used within the plastic hinge zone instead of column full height.

Modified p-y curves to characterize the lateral behavior of helical piles

  • Hyeong-Joo, Kim;James Vincent, Reyes;Peter Rey, Dinoy;Tae-Woong, Park;Hyeong-Soo, Kim;Jun-Young, Kim
    • Geomechanics and Engineering
    • /
    • v.31 no.5
    • /
    • pp.505-518
    • /
    • 2022
  • This study introduces soil resistance multipliers at locations encompassed by the zone of influence of the helix plate to consider the added lateral resistance provided to the helical pile. The zone of influence of a helix plate is a function of its diameter and serves as a boundary condition for the modified soil resistance springs. The concept is based on implementing p-multipliers as a reduction factor for piles in group action. The application of modified p-y springs in the analysis of helical piles allows for better characterization and understanding of the lateral behavior of helical piles, which will help further the development of design methods. To execute the proposed method, a finite difference program, HPCap (Helical Pile Capacity), was developed by the authors using Matlab. The program computes the deflection, shear force, bending moment, and soil resistance of the helical pile and allows the user to freely input the value of the zone of influence and Ω (a coefficient that affects the value of the p-multiplier). Results from ten full-scale lateral load tests on helical piles embedded at depths of 3.0 m with varying shaft diameters, shaft thicknesses, and helix configurations were analyzed to determine the zone of influence and the magnitude of the p-multipliers. The analysis determined that the value of the p-multipliers is influenced by the ratio between the pile embedment length and the shaft diameter (Dp), the effective helix diameter (Dh-Dp), and the zone of influence. Furthermore, the zone of influence is recommended to be 1.75 times the helix diameter (Dh). Using the numerical analysis method presented in this study, the predicted deflections of the various helical pile cases showed good agreement with the observed field test results.

Development and Application of Two-Dimensional Numerical Tank using Desingularized Indirect Boundary Integral Equation Method (비특이화 간접경계적분방정식방법을 이용한 2차원 수치수조 개발 및 적용)

  • Oh, Seunghoon;Cho, Seok-kyu;Jung, Dongho;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.447-457
    • /
    • 2018
  • In this study, a two-dimensional fully nonlinear transient wave numerical tank was developed using a desingularized indirect boundary integral equation method. The desingularized indirect boundary integral equation method is simpler and faster than the conventional boundary element method because special treatment is not required to compute the boundary integral. Numerical simulations were carried out in the time domain using the fourth order Runge-Kutta method. A mixed Eulerian-Lagrangian approach was adapted to reconstruct the free surface at each time step. A numerical damping zone was used to minimize the reflective wave in the downstream region. The interpolating method of a Gaussian radial basis function-type artificial neural network was used to calculate the gradient of the free surface elevation without element connectivity. The desingularized indirect boundary integral equation using an isolated point source and radial basis function has no need for information about the element connectivity and is a meshless method that is numerically more flexible. In order to validate the accuracy of the numerical wave tank based on the desingularized indirect boundary integral equation method and meshless technique, several numerical simulations were carried out. First, a comparison with numerical results according to the type of desingularized source was carried out and confirmed that continuous line sources can be replaced by simply isolated sources. In addition, a propagation simulation of a $2^{nd}$-order Stokes wave was carried out and compared with an analytical solution. Finally, simulations of propagating waves in shallow water and propagating waves over a submerged bar were also carried and compared with published data.

A Study on the Plastic Flow of Axisymmetric Forward Extrusion of Tubes Using Upper-Bound Analysis (上界解法에 의한 軸對稱 管의 前方押出時 塑性流動 硏究)

  • 한철호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1314-1321
    • /
    • 1992
  • In analyzing the plastic flow of axisymmetric tube extrusion a new method of formulation using the stream function approach and upper-bound theorem is proposed which permits the prediction of plastically deformed zone in analytic expression as well as metal flow. It is shown that the formulation proposed in this work covers the solid extrusion and tube extrusion in axisymmetric case. The effect of some process parameters such as area reduction, the ratio of radii(inner radius to outer radius) and friction factor on extrusion pressure, deformation zone and plastic flow through stream-lined dies has been studied. The presented theoretical analysis can be effectively used for the prediction of deformation zone and plastic flow.

Design and control of quiet zone (principle and example) (조용한 공간 만들기 (방법론과 예))

  • Kim, Yang-Han;Yun, Du-Byeong;Nam, Gyeong-Uk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.565-570
    • /
    • 2000
  • In order to make a quiet zone, one can consider methods to generate a secondary sound field that cancels a primary sound field. Active noise control (ANC) is one of the kinds. This paper mainly deals with the issues on determining the optimal positions of control sources and sensors for making a desired quiet zone. The issues address the reason why the positions are important, how the positions are optimized, and what the measure on the optimal positions is in an uncertain sound field. It is also shown that a power control is applicable to a specific uncertain sound field. In addition, this paper shows that a control material method, which passively changes a boundary condition, is essentially found to be on the same road of ANC.

  • PDF

Prediction of Crack Growth Retardation Behavior by Single Overload (단일 과대 하중에 의한 균열 성장 지연 거동 예측)

  • 송삼흥;최진호;김기석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.928-932
    • /
    • 1996
  • Single overload fatigue tests with overload sizes ranging from 50% and 100% have been performed to investing ate the fatigue crack growth retardation behavior. A modified and experimental method of Willenborg's model for prediction of crack growth retardation behavior has been developed, based on evaluations of equivalent plastic zone size (EPZS) changing its size along the overload plastic zone boundary. The minimum crack growth rates of each overload size are linearly decreased with overload size increasing, but fatigue lives extended by single overload are increasing much more unlike the crack growth rates. Comparisons of crack growth behavior predicted by EPZS model and Willenborg model have shown that the EPZS model accounts for overload effects better than Willenborg model. These effects include delayed retardation, large retardation region, minimum crack growth rate, and the increase rate of crack growth rate in the region crack growth rate recovered.

  • PDF

A Preliminary Study on the Chemical Compositions of Precipitation in the Rural Area of Kyunggi Province near Demilitarized Zone (비무장지대에 인접한 경기도 농촌지역 강수의 화학적 성분에 관한 기초 연구)

  • 박국태;김창호
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.157-164
    • /
    • 1998
  • preliminary study on the chemical compositions of forty seven precipitations from March 1994 to May 1995 In Yeoncheon-gun, which Is adjacent to the southern boundary of demilitarized zone (DMZ) in the northernmost tip of Kyunggi Province has been Performed. The metal cation and anion concentrations were measured by atomic absorption spectrometer and ion chromatography, respectively. pH/lon meter and direct nesslerization method were used for the concentration measurements of $H^+$ ion and $NH_46+$ ions, respectively Based on the data, the quantitative orders of the cation and anion average concentrations were $Ca^{2+}>NH_4^+>Na^+>K^+>Mg^{2+}>H^+ and SO_4^{2+}>Cl^-> NO_3^-$, respectively..The ratio of average total anion concentration to average total cation concentration was 0.97. The average pH value of the precipitations was 5.60. These results, correlation coefficients between the ion concentrations, and monthly variations of pH value and precipitation amount are used for chemical analysis on the environmental Pollution and Pollutant sources In Yeoncheon-gun of Kyunggi province near DMZ.

  • PDF