• Title/Summary/Keyword: boundary resistance

Search Result 468, Processing Time 0.032 seconds

An experimental assessment of resistance reduction and wake modification of a KVLCC model by using outer-layer vertical blades

  • An, Nam Hyun;Ryu, Sang Hoon;Chun, Ho Hwan;Lee, Inwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.1
    • /
    • pp.151-161
    • /
    • 2014
  • In this study, an experimental investigation has been made of the applicability of outer-layer vertical blades to real ship model. After first devised by Hutchins and Choi (2003), the outer-layer vertical blades demonstrated its effectiveness in reducing total drag of flat plate (Park et al., 2011) with maximum drag reduction of 9.6%. With a view to assessing the effect in the flow around a ship, the arrays of outer-layer vertical blades have been installed onto the side bottom and flat bottom of a 300k KVLCC model. A series of towing tank test has been carried out to investigate resistance (CTM) reduction efficiency and improvement of stern wake distribution with varying geometric parameters of the blades array. The installation of vertical blades led to the CTM reduction of 2.15~2.76% near the service speed. The nominal wake fraction was affected marginally by the blades array and the axial velocity distribution tended to be more uniform by the blades array.

Microstructure and Corrosion Characteristics of Austenitic 304 Stainless Steel Subjected to Long-term Aging Heat Treatment (장시간 시효 열처리된 오스테나이트계 304강의 미세조직과 부식 특성)

  • Huh, ChaeEul;Kim, ChungSeok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.56-65
    • /
    • 2022
  • The electrochemical corrosion properties of austenitic AISI 304 steel subjected to a long-term-aging heat treatment were investigated. AISI 304 steel was aged at 700 ℃ for up to 10,000 h. The variation in the microstructure of the aged specimens was observed by optical microscopy and scanning electron microscopy. Electrochemical polarization experiments were performed to obtain the corrosion current density (Icorr) and corrosion potential (Ecorr). Analyses indicated that the metastable intermetallic carbide M23C6 formed near the γ/γ grain boundary and coarsened with increasing aging time; meanwhile, the δ-ferrite decomposed into the σ phase and into M23C6 carbide. As the aging time increased, the current density increased, but the corrosion potential of the austenitic specimen remained high (at least 0.04 ㎛/cm2). Because intergranular carbide was absent, the austenitic annealed specimen exhibited the highest pitting resistance. Consequently, the corrosion resistance of austenitic AISI 304 steel decreased as the aging heat treatment time increased.

Evaluation of Residual Strength and Behavior of Reinforced STG 800 Welded Square Composite Column after Fire 3 Hour (강관철근을 보강한 합성기둥의 3시간 가열 후 잔존 압축력 실험평가)

  • Kim, Sun-Hee;Yom, Kyong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.242-243
    • /
    • 2021
  • The concrete inside the steel tube of CFT columns enables them to have great strength and ductility. CFT columns are also excellent in fire-resistance because explosive heat upon a fire can be contained in the tube by the concrete debris. However, the studies to evaluate the residual strength of CFT columns after a fire have not been conducted enough. The studies to evaluate the residual strength of CFT columns after a fire are indispensable because it is the barometer of the damage of composite columns caused by a fire and the degree of repair and reinforcement work for the columns after a fire. Accordingly, the purpose of this study is to evaluate the deterioration of load capacity and structural behavior of square CFT columns with the same shapes and boundary conditions before and after a fire. The study also evaluates the influential factors of the CFT columns reinforced to secure the residual strength after a fire.

  • PDF

Localized Corrosion Resistance and Microstructural Changes in UNS N07718 Alloy After Solution Heat Treatment

  • Yoon-Hwa Lee;Jun-Seob Lee;Soon il Kwon;Jungho Shin;Je-Hyun Lee
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.166-178
    • /
    • 2024
  • The localized corrosion resistance of UNS N07718 alloy was investigated after solution heat treatment. When the alloy was heat-treated at 1050 ℃ for 2.5 hours, it experienced an increase in average grain diameter, a reduction in grain boundary area, and the dissolution of delta phases along grain boundaries. Additionally, primary metallic nitrides (MN) and metallic carbides (MC), enriched with either Ti or Nb, were identified and exhibited a random distribution within the microstructures. Despite the solution heat treatment, the composition, diameter, and abundance of MNs and MCs remained relatively consistent. The critical pitting temperature (CPT), as determined by the ASTM G48-C immersion test, revealed similar values of 45 ℃ for both treated and untreated alloys. However, a decrease in maximum pit depth and corrosion rate was observed after the solution heat treatment. The microstructural changes that occurred during the heat treatment and their potential implications were discussed to understand the influence of the solution heat treatment.

Correlations between the Impedance and Compressive Strength of Hardened Cement According to the Aggregate Type

  • Hojin Kim;Jinju Kim;Sungyu Park;Je Hyun Bae
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.242-252
    • /
    • 2024
  • To date, methods used to assess the interfacial transition zone (ITZ), which represents the boundary between the aggregate and paste inside concretes, have primarily relied on destructive tests, and non-destructive tests has received little attention until recently. This study assessed the interfaces of concretes with lightweight aggregates based on electrochemical impedance spectroscopy (EIS) for high-strength concretes and examined the possibility of estimating the compressive strength of concretes through non-destructive testing using EIS. The experimental results revealed that the impedance of the hardened cement increased with increasing compressive strength and aggregate density. In particular, when the results of impedance measurement were displayed as a Nyquist plot, the intercept of the x-axis depicting the effective conductivity was proportional to the compressive strength. Furthermore, an equivalent circuit was selected to interpret the correlation between cement aggregates and impedance. Consequently, the compressive strength was found to increase with the value of the resistances of the electrolyte filled in continuous pores in the cement aggregate. And, the pores formed in the ITZ affect this value. The resistance at the ITZ for different aggregates was also obtained, and it was found that the resistance was consistent with the results predicted by SEM images of the ITZ and correlated with the strength of the concretes. The proposed method can be used as a way to easily determine the strength of cement according to differences in aggregate.

The Electrical Characteristics of the Grain Boundary in a $BaTiO_{3}$ PTC Thermistor ($BaTiO_{3}$ PTC 서미스터 입계의 전기적인 특성)

  • Kwon, Hyuk-Joo;Lee, Jae-Sung;Lee, Yong-Soo;Lee, Dong-Kee;Lee, Yong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.67-75
    • /
    • 1992
  • PTC thermistor has been fabricated with as-received $BaTiO_{3}$ powder and its electrical properties were investigated. The resistivity of the PTC thermistor was measured at $20^{\circ}C$ intervals from $20^{\circ}C$ to $200^{\circ}C$. The electrical characteristics of the PTC thermistor are determined by the ac complex impedance analysis. The average grain size measured with a scanning electron microscope increased from $3.8{\mu}m$ to $8.8{\mu}m$ with increasing sintering temperature between $1280^{\circ}C$ and $1400^{\circ}C$. The maximum resistivity jump was $4{\times}10^{5}$. The bulk resistivity of the thermistor sintered above $1340^{\circ}C$ decreased with increasing temperature of the measurement. The grain boundary resistance increased exponentially, the grain boundary capacitance decreased, and the built-in potential at the grain boundary increased with increasing temperature of the measurement. The charge densiy at the grain boundary increased with increasing temperature up to $110^{\circ}C$, which leveled off with further increase in measuring temperature.

  • PDF

A Study on Wear and Corrosion Properties of Plasma Carburized Austenitic Stainless Steel (플라즈마 침탄된 오스테나이트계 스데인리스강의 마모 및 부식 특성에 관한 연구)

  • Shin, Dong-Myung;Lee, Chang-Youl;Lee. Kyung-Sub
    • Korean Journal of Materials Research
    • /
    • v.12 no.10
    • /
    • pp.776-783
    • /
    • 2002
  • Austenitic stainless steel (STS304) has been carburized using glow discharge plasma and its microstructure, wear resistance and corrosion property have been investigated. A repeat boost-diffuse carburizing was used as an effective plasma carburizing method. The effective case depth of the plasma carburized specimens was increased with the carbon concentration at the surface area. The specimens prepared by 3 hours plasma carburizing under $600^{\circ}C$ did not have the standard hardness for the effective case depth, but the specimen prepared by 11 hours plasma carburizing at $500^{\circ}C$ had nearly the same hardness with the specimen plasma carburized for 3 hours at $800^{\circ}C$. The wear resistance increased with temperature but the corrosion properties of the specimens prepared over $600^{\circ}C$ decreased rapidly due to the grain boundary sensitization. However, the specimen plasma carburized for 11 hours at $500^{\circ}C$ had nearly the same wear resistance with the specimen plasma carburized for 3 hours at $800^{\circ}C$ without deterioration of corrosion property. This could be resulted from the fact that the microstructure of the specimen plasma carburized for 11 hours at $500^{\circ}C$ was composed of martensite and austenite, because a partial martensite transformation was occurred only in the specimen plasma carburized for 11 hours at 50$0^{\circ}C$.

THE EFFECTS OF HEAT TREATMENT ON THE MECHANICAL PROPERTIES OF THE ELGILOY WIRE (열처리가 Elgiloy 선재의 기계적 성질에 미치는 영향)

  • Hur, Tack;Rhee, Byung-Tae;Choi, Seok Kyu;Kim, Hyung-Il
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.557-578
    • /
    • 1992
  • Heat treatment which removes internal stress enhances the mechanical properties of the orthodontic arch wire. The main purpose of this experiment was to investigate the effects of the heat treatment on the mechanical properties of the Elgiloy wire. The Elfiloy wire, 0.016' X 0.022' and 0.018' X 0.025', were heat treated in an electric oven for 5, 10 and 15 minutes at selected temperatures between 300 and $900^{\circ}C$. Tensile strength and load deflection rate were measured to reveal the changes of mechanical property at various conditions, and each specimen was observed under metallurgic microscope. Also to trace the precipitation material due to overheat treatment, a qualitative analysis was carried out with EDS system. It was found that heat treatment at a low temperature caused an increase in the tensile strength and bending resistance, and a maintenance in the fibrous in the tensile strength and bending resistance, and a maintenance in the fibrous structure of both sizes of wire. The changes observed in properties and appearance were probably due to the relief of internal stresses incurred in the metal during cold working. In both sizes of wire the tensile strength and the bending resistance continued to decrease at high temperature, and the fibrous structure continued to disappear then was not observed at $900^{\circ}C$. The carbide precipitation founded in grain boundary at $750^{\circ}C$ probably was other elements carbide (Ni, Co) except Cr. The grain growth was observed at $1100^{\circ}C$. Optimum heat treatment for the 0.016' X 0.022' Elgiloy wire was 10 minutes at $500^{\circ}C$, and for the 0.018' X 0.025' Elgiloy wire it was 5 to 15 minutes at $500^{\circ}C$.

  • PDF

High Temperature Corrosion of Alloy 617 in Impure Helium and Air for Very High-Temperature Gas Reactor (초고온가스로용 Alloy 617의 불순물 함유 헬륨/공기 중에서 고온부식 특성)

  • Jung, Sujin;Lee, Gyeong-Geun;Kim, Dong-Jin;Kim, Dae-Jong
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.102-112
    • /
    • 2013
  • A very high-temperature gas reactor (VHTR) is one of the next generation nuclear reactors owing to its safety, high energy efficiency, and proliferation-resistance. Heat is transferred from the primary helium loop to the secondary helium loop through an intermediate heat exchanger (IHX). Under VHTR environment Alloy 617 is being considered a candidate Ni-based superalloy for the IHX of a VHTR, owing to its good creep resistance, phase stability and corrosion resistance at high temperature. In this study, high-temperature corrosion tests were carried out at 850 - $950^{\circ}C$ in air and impure helium environments. Alloy 617 specimens showed a parabolic oxidation behavior for all temperatures and environments. The activation energy for oxidation was 154 kJ/mol in helium environment, and 261 kJ/mol in an air environment. The scanning electron microscope (SEM) and energy-dispersive x-ray spectroscopy (EDS) results revealed that there were a Cr-rich surface oxide layer, Al-rich internal oxides and depletion of grain boundary carbide after corrosion test. The thickness and depths of degraded layers also showed a parabolic relationship with the time. A corrosion rate of $950^{\circ}C$ in impure helium was higher than that in an air environment, caused by difference in the outer oxide morphology.

An Experimental Study of Improving Fire Performance with Steel-fibers for Internally Anchored Square Composite Columns (내화성능 개선을 위한 강섬유 보강 내부 앵커형 각형강관 합성기둥의 실험연구)

  • Kim, Sun Hee;Yom, Kong Soo;Kim, Yong Hwan;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.499-509
    • /
    • 2014
  • This study focuses on mixing steel fiber in the concrete to improve the ductility and toughness of the columns. The purpose of the study is to evaluate the load capacity and deformation capacity associated with the amount of steel fiber and loading condition and to analyze the interplay between the steel fiber reinforced concrete and the welding built-up square tube in terms of structure and fire resistance performance. Reinforcement of concrete with steel fiber(Vf=0.375%), when cross-section shape and boundary condition (load ratio) remained unchanged, improved fire resistance performance by 1.1~1.3 times. It is deemed that the area resisting thermal load increased and fire resistance performance was improved since the concrete reinforced with steel fiber restrained cracking. In addition, the fact that the cross-sections of the concrete were barely damaged indicates that load share capacity was greatly improved.