Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.

A Study on the Effect on Sauce Selection and Preference of Demi-glace Sauce by Material - Focused on the Restaurants in Gwang-ju and South Jeolla Province - (데미글라스 소스의 재료별 선호도와 소스 선택에 미치는 영향에 관한 연구 - 광주.전남 레스토랑을 중심으로 -)

  • Yang, Young-Nam;Se, Young-Kyu;Park, Gye-Young
    • Culinary science and hospitality research
    • /
    • v.12 no.3 s.30
    • /
    • pp.151-163
    • /
    • 2006
  • The sauce is very important to western dishes and also to value and relish of dishes because taste, appearance and the degree of water content are determined by sauce. Also, the taste derived from major sauce like a demi-glace and the basic sauce that affects cooking quality are highly recognized, but preference analyses of source and researches on each ingredients have not been performed up to now. Until today, sauces act as lubricants which add relish to dishes and aid digestion, so the importance of source is more emphasized to raise the taste, appearance, water content and specially healthy function of main ingredients. In this research, some problems of sauce itself and possibilities of improvement was grasped and then some remedies were suggested through the preference, variety and quantity analyses of demi-glace sauce practically used in hotels and restaurants around Gwang-Ju City and South Jeolla(Chon-Nam) Province. Finally, the volume of demi-glace sauce with various ingredients was suggested for various kinds of application. Through the actual proof analysis, preference of each sauce made from various kinds of ingredients was investigated. The result shows that the sauce made from beef bone is highly preferred, followed by pork bone and lamb bone. The least preferred is chicken bone.

  • PDF

The Effects of Prostaglandin E2 and Indomethacin on Quantitative Change in Collagen and Chondroitin Sulfate in the Alveolar Bone of Rats (Prostaglandin E2와 Indomethacin이 백서 치조골 내 Collagen과 Chondroitin Sulfate의 정량 변화에 미치는 영향)

  • Park, Sei Jin;Sohn, Byung Wha
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.247-266
    • /
    • 1990
  • The alveolar bone remodeling is essential in tooth movement by orthodontic forces. The collagen and chondroitin sulfate are acting as an important roles in bone remodeling. This study was performed to measure out the quantity of the collagen and chondroitin sulfate in the alveolar bone of rats applied by experimental orthodontic forces. The 150 Sprague-Dawley male rats were divided into the $PGE_2$ treated group, indomethacin treated group and the normal group. A 80gm force rubber band was used as a orthodontic appliance between upper incisors and right upper 1st molar, and left side of experimental rats with no appliance was regarded as a control side. The samples of alveolar bones were obtained from pressure and tension sites in all three groups. respectively, and in control sides, too. The results were as follows. 1. The change in total collagen remains stable in both pressure and tension sites of all three groups, compared with control side by the time consuming. 2. The change in soluble collagen showed the most highest level in tension site, lowest level in pressure site of $PGE_2$ treated group in 5th. experimental day. 3. The change in chondroitin sulfate showed the most highest level in pressure site, lowest level in tension site of $PGE_2$ treated group in 5th. experimental day. 4. In indomethacin treated group, the change of soluble collagen and chondroitin sulfate showed small range of variance compared with $PGE_2$ treated and normal group.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION ACCORDING TO THE SLOPES OF THE CHIDING PLANES OF THE ABUTMENTS (지대치 유도면의 기울기에 따른 응력 분포에 대한 연구)

  • Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.293-301
    • /
    • 1998
  • The purpose of this study was to investigate the effects of load on root that was applied to edentulous area in three simulated situation, in each case the guiding planes of abutment were right vertical, 95 degrees, or 100 degrees to residual ridge. The 2-dimensional finite element method was used and the finite element model was prepared as fellows. Right mandibular 1st and 2nd molar was lost and the 2nd premolar with distal rest was used as primary abutment which had three different degrees of guiding plane. Then 150N of compressive force was applied to central fossae of the 1st and 2nd molars and von Mises stress and displacement was measured. The results were as follows; 1. Irrespective of slopes of guiding planes, the stress was concentrated on mesial side of root apex and distal side of coronal portion of root, in particular on junction with distal alveolar bone. As slopes of guiding planes were increased. stress on root and compact bone surrounding abutment was increased but no considerable effect was seen on compact bone of residual ridge. 2. Distal side of coronal portion of root limited by periodontal ligament was displaced distally and mesial side of apical portion was mesially. With slope of guiding plane increasing, the pattern of displacement was similar with one another but the quantity was increased. 3. Both abutment & alveolar bone were displaced downward and root of abutment, especially distal side of coronal portion, was displaced severely. As the guiding plane was tiffed more mesially over $90^{\circ}$, the degree of displacement was also increased.

  • PDF

Effects of Conjugated Linoleic Acid Feeding Levels and Periods on CLA Content and Blood Characteristics of Pork (Conjugated Linoleic Acid (CLA) 급여량과 급여기간이 돈육의 CLA 함량 및 혈액성상에 미치는 영향)

  • 이정일;최진성;박준철;박종대;김영화;문홍길;주선태;박구부
    • Food Science of Animal Resources
    • /
    • v.21 no.3
    • /
    • pp.215-226
    • /
    • 2001
  • The CLA used to add in diet was chemically synthesized by alkaline isomerization method with corn oil. To investigated the effects of conjugated linoleic acid(CLA) added diet feeding on CLA accumulation and blood characteristics of pork, a total of 64 Landrace was fed both CLA-free and CLA-added(0.3, 0.6 and 0.9%) diet for 1∼4 weeks. Cholesterol compositions in blood and CLA contents and fatty acid compositions of loin, belly, bone and skin were determined at 1, 2, 3 and 4 weeks after CLA added at fed. The HDL content in blood of all treatments was higher(P<0.05) than that of control and that of treatment 3 was higher(P<0.05) than that of other treatments among the CLA feeding periods. Palmitic, stearic and linolenic acids composition of loin and belly was increased but oleic, linoleic and arachidonic acids composition of them was decreased according to increasing the CLA feeding periods. CLA contents of loin and belly were higher than that of control and increased according to increasing the quantity of CLA and CLA feeding periods. CLA contents of bone and skin were higher than that of control, too. CLA content of skin was higher than that of bone. It was suggested that CLA could be accumulated in loin, belly, bone and skin by dietary CLA supplementation, and the CLA concentration and fatty acid composition in muscle could be affected by CLA level in diet and feeding period.

  • PDF

Retrospective analysis of $frialit-2^{(R)}$ implant system placed in maxilla (상악에 식립된 Frialit-2 임플란트의 성공률에 대한 후향적 연구)

  • Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Shim, June-Sung;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.449-460
    • /
    • 2005
  • Objectives Aim of this study was to evaluate the clinical use and the efficacy of Frialit-2 implant system. Experimental Methods Fifty nine patients received placement of Frilalit-2 implants(137 implants) in their maxillary anterior and posterior sites(40 and 97 implants). Intraoral & clinical examination, chart review and radiographs were taken from each patient. Results 1. The total implant survival rate was 92.7% after a mean follow-up period of 19.9 months. 2. The implant survival rate placed in anterior region was 97.5%. 3. The implant survival rate placed in posterior region was 90.7%. 4. The implant survival rate placed in atrophic posterior maxilla with advanced technique (GBR, Sinus elevation) was 87.2%. 5. The implant survival rate placed in type N(D4) bone was 82%, while 95.7% in type III (D3), and 100% in type II(D2) bone. 6. Most of the failed implants(7 of 10) were removed during the maintenance stage after prosthodontic treatment. Conclusion It was concluded that Frialit-2 implant could be used satisfactorily in the esthetic anterior region, but the use in the posterior region, especially with poor bone quality and quantity, further studies are needed.

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.

The Effects of Leg Blood Flow Restriction Exercise on Muscle Size and Muscle Strength (하지 혈류제한 운동이 근육크기와 근력에 미치는 영향)

  • Kwon, Hae-Yeon;Ahn, So-Youn
    • PNF and Movement
    • /
    • v.10 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate thigh muscle-bone CSA and leg strength during low-intensity exercise program with leg blood flow restriction by external compression to reduce muscle outflow. Methods : Eighteen health students gave informed written consent to participate in this investigation. An occlusion cuff was attached to the proximal end of the leg so that blood flow was reduced during the training. The training was conducted one times a day, three times a week, for 8 weeks using one sets of 30 minutes. The training program performed to squat with standing, lunge with standing and heel raise with one leg standing. Measurements of thigh muscle-bone CSA(cross-sectional area) and leg strength were evaluated pre and post-training. Statistical evaluation of these data was accomplished utilizing a paired t-test by SPSS 12.0 program for windows. Significance level was set at p <.05. Results : All data are reported as means and standard deviations(SD) for all variables. The result of the study is followed; After the training, muscle-bone CSA, gluteus maximus m, quadriceps m, hamstring m of both legs were significantly improved but not calf muscle(p<.05). There was no significant difference of change quantity between muscle-bone CSA and leg strength in Lt. and Rt. side. But the variation in leg muscle strength of Rt. leg(dominant) was much more increased than Lt. leg(non-dominant) after 8 weeks training. Conclusion : Low-intensity training with leg blood flow restriction offers a potentially useful method for improving leg muscle strength.

Ten technical aspects of baseplate fixation in reverse total shoulder arthroplasty for patients without glenoid bone loss: a systematic review

  • Reinier W.A. Spek;Lotje A. Hoogervorst;Rob C. Brink;Jan W. Schoones;Derek F.P. van Deurzen;Michel P.J. van den Bekerom
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.88-107
    • /
    • 2024
  • The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE (임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석)

  • Chung Kyung-Min;Chung Chae-Heon;Jeong Seung-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.