• Title/Summary/Keyword: bone quality

Search Result 700, Processing Time 0.028 seconds

The Sensory Characteristics of Brown Sauce by Adding Different Ratio of Chicken Bone (닭뼈 혼합비에 따른 Brown Sauce의 관능적 성질)

  • Lee, Jong-Pil
    • Culinary science and hospitality research
    • /
    • v.12 no.1 s.28
    • /
    • pp.82-92
    • /
    • 2006
  • The purpose of this study was to investigate sensory characteristics of brown sauce made with different ratio of chicken bone. Brown sauces made from chicken bone and beef bone respectively were evaluated by pH, viscosity, turbidity, Hunter's color and sensory evaluation. With chicken bone increased, pH of brown sauce changed from 5.11 to 5.72 (p<0.05) that was lower than optimal bacterial growth condition between 6.8 and 7.0. Viscosity increased with higher chicken bone ratio (p<0.05) and desired viscosity can be obtained by controlling chicken bone content. Turbidity increased with chicken bone (p<0.05), which might be caused by the thick chicken bone extract. Lower Hunter "L" value and higher "a" and "b" value were shown with increase of chicken bone (p<0.05). The sensory evaluation was performed with scoring tests for color, flavor, viscosity and taste by 20 professional panels who were professional cooks working in I hotel. Better scores of color, flavor, taste and overall evaluation except viscosity were observed with increase of cattle bone (p<0.05). There was not a significant difference between chicken bone and beef bone 0.0 : 10.0 and 2.5 : 7.5 (p>0.05). Brown sauce made with 2.5 : 7.5 can be prepared without reducing sensory quality.

  • PDF

FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE (재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석)

  • Kim, Su-Gwan;Kim, Jae-Duk;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

Bone formation around rhBMP-2-coated implants in rabbit sinuses with or without absorbable collagen sponge grafting

  • Baek, Won-Sun;Yoon, So-Ra;Lim, Hyun-Chang;Lee, Jung-Seok;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.238-246
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate bone formation around recombinant human bone morphogenetic protein (rhBMP-2)-coated implants placed with or without absorbable collagen sponge (ACS) in rabbit maxillary sinuses. Methods: The Schneiderian membrane was elevated and an implant was placed in 24 sinuses in 12 rabbits. The space created beneath the elevated membrane was filled with either blood (n=6) or ACS (n=6). In the rabbits in which this space was filled with blood, rhBMP-2-coated and non-coated implants were alternately placed on different sides. The resulting groups were referred to as the BC and BN groups, respectively. The AC and AN groups were produced in ACS-grafted rabbits in the same manner. Radiographic and histomorphometric analyses were performed after eight weeks of healing. Results: In micro-computed tomography analysis, the total augmented volume and new bone volume were significantly greater in the ACS-grafted sinuses than in the blood-filled sinuses (P<0.05). The histometric analysis showed that the areas of new bone and bone-to-implant contact were significantly larger in the AC group than in the AN group (P<0.05). In contrast, none of the parameters differed significantly between the BC and BN groups. Conclusions: The results of this pilot study indicate that the insertion of ACS after elevating the Schneiderian membrane, simultaneously with implant placement, can significantly increase the volume of the augmentation. However, in the present study, the rhBMP-2 coating exhibited limited effectiveness in enhancing the quantity and quality of regenerated bone.

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

CBCT study of mandibular first molars with a distolingual root in Koreans

  • Kim, Hee-Ho;Jo, Hyoung-Hoon;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.33.1-33.8
    • /
    • 2018
  • Objectives: This study aimed to investigate the prevalence of a separate distolingual root and to measure the thickness of the buccal cortical bone in mandibular first molars in Koreans using cone-beam computed tomography (CBCT) images. Materials and Methods: High-quality CBCT data from 432 patients were analyzed in this study. The prevalence of a separate distolingual root of the mandibular first molar was investigated. The distance from the distobuccal and distolingual root apices to the outer surface of the buccal cortical bone was measured. We also evaluated the thickness of the buccal cortical bone. Results: The prevalence of a separate distolingual root (2 separate distal roots with 1 canal in each root; 2R2C) was 23.26%. In mandibular first molars with 2R2C, the distance from the distobuccal root apex to the outer surface of the buccal cortical bone was 5.51 mm. Furthermore, the distance from the distolingual root apex to the outer surface of the buccal cortical bone was 12.09 mm. In mandibular first molars with 2R2C morphology, the thickness of the buccal cortical bone at the distobuccal root apex of the mandibular first molar was 3.30 mm. The buccal cortical bone at the distobuccal root apex was significantly thicker in the right side (3.38 mm) than the left side (3.09 mm) (p < 0.05). Conclusions: A separate distolingual root is not rare in mandibular first molars in the Korean population. Anatomic and morphologic knowledge of the mandibular first molar can be useful in treatment planning, including surgical endodontic treatment.

Physicochemical attributes, oxidative stability, and microbial profile of boneless sirloin and bone-in T-bone steaks from Hanwoo steer with reference to dry-aging

  • Ali, Mahabbat;Nam, Ki-Chang
    • Journal of Animal Science and Technology
    • /
    • v.63 no.5
    • /
    • pp.1169-1181
    • /
    • 2021
  • We investigated the comparative physicochemical attributes, oxidative stability, and microbial characteristics of 28 days dry-aged meat in between boneless sirloin (gluteus medius) and bone-in T-bone steaks (infraspinatus) muscles from Korean Native Hanwoo Steer (KNHS). Results reveal that regardless of the muscles, dry-aging increased protein content and water-holding capacity (WHC) (p < 0.05). Meat from infraspinatus-aged muscle led to darker meat with higher pH values than un-aged meat (p < 0.05). However, fat content, CIE a*, and CIE b* remained unchanged in both muscles at aging. At aged meat, thiobarbituric acid reactive substances (TBARS) values from bone-in infraspinatus muscle was 2.5-fold higher than boneless gluteus medius muscle (p < 0.05). Dry-aging led to an increase in the contents of total unsaturated fatty acids (UFAs), monounsaturated fatty acids (MUFAs), and UFA/saturated fatty acids (SFA) in both muscles (p < 0.05). Furthermore, gluteus medius aged muscle concentrated with olic acid (C18:1) compared to infraspinatus aged muscle. Irrespective of the muscles, dry-aging enhanced the total free amino acids (FAAs) as well as tasty, and bitter amino acid contents whereas decreased the tasty/bitter amino acids (p < 0.05). Aromatic amino acid, tryptophan that converted to serotonin was 2-fold higher in boneless gluteus medius muscle than bone-in infraspinatus muscle at pre and post aging processes (p < 0.05). Aged Infraspinatus muscle increased total bacteria (p < 0.05) while no salmonella spp. was detected in both muscles. Taken together, our study confirms that 28 days dry-aging profiling the quality characteristics of boneless sirloin (gluteus medius) and bone-in T-bone steaks (infraspinatus) distinctly while gluteus medius aged steak performs better owing to oxidative stability and functional compounds than infraspinatus aged steak.

Association between Low Hand Grip Strength and Decreased Femoral Neck Bone Mineral Density in Korean Fishery Workers (어업종사자에서 낮은 악력과 대퇴부 경부 골밀도 감소의 연관성)

  • Mi-Ji Kim;Gyeong-Ye Lee;Joo Hyun Sung;Seok Jin Hong;Ki-Soo Park
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.4
    • /
    • pp.275-284
    • /
    • 2023
  • Objectives: This study aimed to assess hand grip strength and femoral neck bone mineral density levels among Korean fishery workers and investigate their association. Methods: Hand grip strength and femoral neck bone mineral density were measured in a survey and health examination conducted in 2021 among fishery workers in a southern region of South Korea. Covariates including gender, age, education level, income level, smoking behavior, drinking behavior, family history of hip fractures, use of calcium and vitamin D supplements, hypertension, diabetes, regular exercise, and body mass index were investigated. Multiple regression analysis was employed to assess the association between hand grip strength and femoral neck bone mineral density. Results: Among 147 fishery workers, 8.16% exhibited low hand grip strength levels indicative of possible sarcopenia, and a significant association was found between low hand grip strength and decreased femoral neck bone mineral density (β = -89.14, 95% CI = -160.50, -17.78). Additionally, factors such as women gender, advanced age, family history of hip fractures, and a body mass index below 25 kg/m2 were associated with decreased femoral neck bone mineral density. In the subgroup analysis by gender, a correlation between low hand grip strength and decreased femoral neck bone mineral density was observed only in men. Conclusions: Further research is needed to explore various determinants and intervention strategies to prevent musculoskeletal disorders among fishery workers, ultimately enhancing their quality of life and well-being.

A Study of Segmentation for 3D Visualization In Dental Computed Tomography image (치과용 CT영상의 3차원 Visualization을 위한 Segmentation에 관한 연구)

  • 민상기;채옥삼
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.177-180
    • /
    • 2000
  • CT images are sequential images that provide medical doctors helpful information for treatment and surgical operation. It is also widely used for the 3D reconstruction of human bone and organs. In the 3D reconstruction, the quality of the reconstructed 3D model heavily depends on the segmentation results. In this paper, we propose an algorithm suitable for the segmentation of teeth and the maxilofacial bone.

  • PDF

Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level (치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석)

  • Jeon, Chang-Sik;Jeong, Sin-Young;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.