• 제목/요약/키워드: bone plate and screw

검색결과 77건 처리시간 0.024초

해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료 (Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture)

  • 정형진
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

One-Stage Treatment of Chronic Calcaneal Osteomyelitis with Bone Morphogenetic Protein 2 and Local Antibiotic Delivery in a Cat

  • Kim, Hyungkyoo;Jeong, Heejun;Park, Chul;So, Kyung-Min;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • 한국임상수의학회지
    • /
    • 제33권5호
    • /
    • pp.300-303
    • /
    • 2016
  • An age-unknown, 4.8 kg, male, wild, domestic short-hair cat was presented for left hindlimb lameness. A physical examination revealed a draining tract which was suspected of bite on left calcaneal bone. The left tarsal joint was markedly swollen and exudates were observed around the draining tract. Sequestrum at left calcaneus bone, and osteolysis were identified by radiography. The sequestrum and its surrounding exudative tissue were debrided during surgery and the tissue was submitted for bacterial culture and sensitivity test. The debridement caused a bone defect ($1.5cm{\times}0.5cm{\times}0.5cm$) on the medial left calcaneal bone. Plate and screw fixation was performed to the calcaneus bone as buttress plate. Recombinant human bone morphogenetic protein-2 (rhBMP-2) loaded hydroxyapatite was implanted in the bone defect. Furthermore, Amikacin-impregnated collagen sponges were also placed around bone plate to deliver local antibiotics. A systemic antibiotic treatment regimen based on bacterial culture and sensitivity test results was administered for 4 weeks. The wound properly healed without any signs of infection, and the bone healing was confirmed by radiography. The patient showed normal weight bearing ambulation at 18 weeks after surgery. The use of rhBMP-2 and local antibiotic delivery system is a good surgical option for the one-stage treatment of chronic osteomyelitis.

총상 골절 개에서 자가골 이식과 주관절 고정술 (Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog)

  • 이종일;알람;김남수
    • 한국임상수의학회지
    • /
    • 제22권1호
    • /
    • pp.60-64
    • /
    • 2005
  • 체중 23kg, 나이 6세된 수캐 잡종 사냥개가 왼쪽 주관절에 총상을 입어 전북대학교 수의과대학 동물병원에 내원하였다. 방사선 사진에서 요골 척골 근위부에 복잡골절과 주관절 돌기 후방에 금속성 탄환이 발견되었다. 첫 번째 외과처치는 탄환을 제거하고 bone plate, bone screw, K-wire등을 이용하여 정복 고정하였으나 실패하였다. 두 번째 시도는 주관철 고정술과 13번째 늑골로부터 얻은 자가골을 이용하여 결손부를 충진 하였다. 결과가 만족스럽지 못하여 자가골 재이식과 3번째 수술을 실시하여 주관절의 안정된 고정상태를 유지 할 수 있었다. 60주가 지난 현재 평상시 활동에는 커다란 문제점이 없지만 속보 혹은 뛰는 경우 관절 고정술을 실시한 다리를 들고 세 다리만 사용하는 아쉬움이 있다.

흡수성 스크류를 이용한 하악과두 골절의 치료 (TREATMENT OF CONDYLE FRACTURE WITH RESORBABLE SCREW)

  • 여인범;민승기;오승환;권경환;최상문;박상규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.559-564
    • /
    • 2006
  • According to the development of operation technique and biologic materials, oromaxillofacial surgery department have used many kinds of metal and biologic materials in ORIF and plastic surgery. In maxillofacial fracture, ORIF with metal plate and screw have short healing period and good prognosis. But ORIF with metal materials have many complications as maxillofacial abnormal growth, screw loosening, bone malunion. And metal materials have not used in infection site. The purpose of this study is to evaluate the clinical value of 10 condylar fracture patients operated with absorbable screw at Wonkwang university. Ten patients(8 males, 2 female, mean aged 28) who had mandibular condyle process fracture treated with PLLA implants(poly-l-lactide) was recalled for follow-up clinical and radiologic examination for 10 years. Mouth opening recorvered to more than 35mm and occlusion was stable in all patients. All fractured mandibular condyles showed anatomic good reduction and long-term stability with the use of resorbable miniplates and screw. Bone healing was satisfactory in all patients, and there was no evidence of abnormal resorption of condylar process.

종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교 (Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures)

  • 이윤태;오현철;윤한국;장재원;장기준
    • 대한족부족관절학회지
    • /
    • 제16권3호
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

하악골 시상골 골절단술시 MINIPLATE에 의한 RIGID FIXATION (RIGID FIXATION BY MINIPLATE IN THE MANDIBULAR SAGITTAL SPLITRAMUS OSTEOTOMY.)

  • 조병욱;이용찬;양용석;유하식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권2호
    • /
    • pp.48-54
    • /
    • 1990
  • This is a report of 4 cases of the surgical correction of mandibular prognathism with chief complaint of mastication difficulty, facial asymmetry and protrusive chin. We performed sagittal spit ramus osteotomy for the prognathism, we used the repositioning plate for conserving the condylar segment into its original position and fixed the osteotomized bone segments rigidly with adjustable monocortical plate. Intermaxillary fixation was performed during 2 weeks. As a results, we found the following advantage. 1. Rigid fixation effect like the fixation by the tandem screw. 2. Decreased postoprative swelling. 3. It is needless to do the stab incision for the transbuccal set instrument. 4. It is more convenient to perform the rigid fixation in the monocortical plate method than screw technique.

  • PDF

골 접촉 곡선형 금속 고정 시스템 구현 (Implementation of curved type a metallic plate system at the Bone contact)

  • 김정래
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권5호
    • /
    • pp.285-292
    • /
    • 2007
  • 본 논문은 정형외과영역인 대퇴부에 고정하여 사용하는 금속판으로 골 고정 골절치료의 유합술 골절치료를 할 수 있도록 구성하였는데, 사용되는 치료방법은 견고하고, 안정적이며, 역동적인 생물학적 금속판으로 고정 골수강 내 고정술을 적용되도록 견고한 골접촉 곡선형 시스템을 분석하였다. 금속판은 두 가지 유형으로 장형과 단형으로 구성되고, 금속판의 굴곡이 구조적이고 기하학적으로 경성 및 강도가 고루 분포하도록 최적화 하였다. 장 플레이트의 골접촉에 따른 곡선형으로 굽힙강도는 11,000N 이고, 단 플레이트의 골접촉에 따른 곡선형으로 굽힙강도는 6,525N 이며, 금속판에 골편간 압박을 주는 인장강도는 $1573N/m^2,\;1539N/m^2$정도이다. 금속판은 곡선부와 금속판부의 두 가지 부분으로 나뉘어져 있는데, 곡선부만 있는 단형과 밑 부분의 금속판이 달려있는 장형으로 진행되며, 곡선부의 단형은 전체적인 Profile이 낮고, 금속판이 달려있는 장형은 슬리브의 일체형으로 Profile보다 약간 높아져서 있다. 본 논문의 결과로 제공되는 것은 Hip Implant의 Revision case에 있어 보완뿐만 아니라 Hip Neck Fracture 경우에 사용되었던 Compression Hip Screw의 사용이 가능할 것으로 예상된다.

  • PDF

Guided Bone Regeneration in Comminuted Long-Bone Fractures Using Recombinant Human Bone Morphogenetic Protein-2 and a Collagen Membrane

  • Jang, Kwangsik;Jo, Hyun Min;Shim, Kyung Mi;Kim, Se Eun;Kang, Seong Soo
    • 한국임상수의학회지
    • /
    • 제39권2호
    • /
    • pp.59-64
    • /
    • 2022
  • A dog aged two years and seven months and a cat aged seven years were referred owing to fractures of long bones. Preoperative radiographs revealed comminuted bone fractures close to joints. Conventionally, long-bone fractures are treated using intramedullary pins, plate and screw systems, or an external fixator system. In cases of non-reducible fractures, various graft materials have been used in fracture treatments to stimulate bone repair. Here, recombinant human bone morphogenetic protein-2 (rhBMP-2) and a collagen membrane were applied. Four weeks after surgery, fractured bone fragments began to unite and the bone union was observed using radiography four months after surgery. No complications occurred related to grafted materials. We successfully applied rhBMP-2 and collagen membranes in two different species to support the healing process of comminuted fractures, according to the concept of guided bone regeneration.

Mini-open Treatment Using Plate of Clavicle Mid-shaft Fractures

  • Park, Yong-Geun;Kang, Hyunseong;Kim, Shinil;Bae, Jong-Hwan;Choi, Sungwook
    • Clinics in Shoulder and Elbow
    • /
    • 제20권1호
    • /
    • pp.37-41
    • /
    • 2017
  • Background: Increased frequency of comminuted clavicle mid-shaft fractures and importance of functional satisfaction through early joint exercise has resulted in higher emphasis on surgical treatments. This study aimed to evaluate the clinical radiological results of treatment of clavicle mid-shaft fractures by open reduction and internal fixation using a plate with a small incision. Methods: The subjects of this study were 80 clavicle mid-shaft fracture cases treated with internal fixation using a plate from October 2010 to July 2014. Clavicle mid-shaft fractures were internally fixated using anatomical plates or locking compression plates. Achievement of bone union, union period, and clavicle length shortening were evaluated radiologically, and clinical assessment was done by using Constant and University of California at Los Angeles (UCLA) scores. Results: All 80 cases were confirmed to have achieved bone union through radiographs with an average union period of 10.9 weeks (range: 7-18 weeks). The average clavicle length of shortening in the affected side was 1.8 mm (range: 0-17 mm). The average UCLA score and Constant score were 33.6 (range: 25-35) and 92.5 (range: 65-100), respectively. Regarding complications, four cases reported skin irritation by metal plates, and one case reported a screw insertion site fracture due to minor trauma history. Conclusions: We were able to induce successful bone union and obtain clinically satisfactory results in displaced mid-shaft fractures of the clavicle without major complications such as nonunion through treatment of internal fixation using a plate.