• 제목/요약/키워드: body-voltage

검색결과 477건 처리시간 0.123초

표면전류분석을 이용한 전착도막의 표면 균질성 평가 (Steel Surface Uniformity Assesment Method for Electrocoating by Applying Low Current and Voltage)

  • 양원석;이창용;정유동;문만빈;황운석
    • Corrosion Science and Technology
    • /
    • 제12권6호
    • /
    • pp.288-294
    • /
    • 2013
  • When the automotive body enters an electrocoating tank while applying an electric current, its steel surface is exposed to a very low induced current. Consequently, surface defects of coating may arise if the steel surface has lack of electric uniformity due to local defects such as local oxide. In this study, we investigated the preceding assessment methods to evaluate steel susceptibility of the low induced current during electrocoating before mass production. Prior to general electrocoating, we applied low constant voltage such as 3V or low constant current densities such as $0.35mA/cm^2$ and $0.50mA/cm^2$. In result, we confirmed that such methods were efficient for assessing steel susceptibility of low induce current during electrocoating.

Dynamic 방법을 이용한$ LiTaO_3$ 단결정의 초전특성에 대한 연구 (A Study on the Pyroelectric Effects of $LiTaO_3$ Single Crystal by Using the Dynamic Method)

  • 강성준;정양희
    • 한국정보통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.454-460
    • /
    • 2003
  • The modulated frequency dependence on the pyroelectric properties of LiTaO$_3$ single crystal was investigated by the dynamic method. The pyroelectric coefficient of LiTaO$_3$ single crystal was 2.1${\times}$$10^{-8}$/$\textrm{cm}^2$ㆍK. and figure of merits for the responsivity and the detectivity were 1.31${\times}$$10^{-10}$Cㆍcm/J and 1.47${\times}$$10^{-8}$C\ulcornercm/J. respectively. The voltage responsivity corresponded with the pyroelectric voltage exhibited the highest value as about 165V /W at 4Hz and then was in inverse proportion to the frequency over 20Hz. The noise equivalent power and the detectivity at 4Hz were 8.4${\times}$$10^{-9}$ W/Hz$^{1}$2/ and 2.2${\times}$$10^{7}$ cmㆍHz$^{1}$2//W, respectively. Therefore, we could found that LiTaO$_3$ single crystal shows a excellent pyroelectric properties in low frequency region for the human body detection.tection.

터널링 전계효과 트랜지스터의 불순물 분포 변동 효과 (Random Dopant Fluctuation Effects of Tunneling Field-Effect Transistors (TFETs))

  • 장정식;이현국;최우영
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.179-183
    • /
    • 2012
  • 3차원 시뮬레이션을 이용하여 터널링 전계효과 트랜지스터(TFET)의 불순물 분포 변동(RDF) 효과에 대해 살펴보았다. TFET의 RDF 효과는 매우 낮은 바디 도핑 농도 때문에 많이 논의되지 않았다. 하지만 본 논문에서는 임의로 생성되고 분포되는 소스 불순물이 TFET의 문턱전압 ($V_{th}$)과 드레인 유기 전류 증가 (DICE), 문턱전압이하 기울기 (SS)의 변화를 증가시킴을 발견하였다. 또한, TFET의 RDF 효과를 감소시킬 수 있는 몇 가지 방법을 제시하였다.

저전압 MEMS 스위치를 적용한 휴대단말기의 인체효과 보상회로 설계 (Hand-effect compensation circuit design using the low-voltage MEMS switch in the handset)

  • 김왕진;이국주;박용희;김문일
    • 전기전자학회논문지
    • /
    • 제13권3호
    • /
    • pp.1-6
    • /
    • 2009
  • 인체효과로 인해 발생된 안테나 성능의 저하를 보상하기 위하여 외부 보상회로를 설계하였다. 두 가지의 보상회로의 구조를 비교하여 스위치 스트레스를 최소화할 수 있는 구조를 선택하였다. 이후 선택된 보상 회로를 이용하여 저전압에서 사용할 수 있는 MEMS 스위치를 제공받아 FET스위치와 비교하고, 이 스위치를 휴대용 단말기에 적용하여 실험하였다. 이때 안테나로부터의 반사파를 감지하는 회로를 추가하여 인체효과 발생 시 자동적으로 보상회로가 동작되도록 프로그램 하여 데모시스템을 구축하였다. 이 시스템을 이용하여 인체효과 발생으로 인한 안테나의 성능을 보상회로를 동작시킴으로써 방사전력이 2.5dB 향상되는 것을 확인하였다.

  • PDF

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

Electrodermal Activity at Palms according to Pressure Stimuli applied to the Scapula

  • Kim, Jae-Hyung;Park, Gun-Cheol;Baik, Sung-Wan;Jeon, Gye-Rok
    • 한국멀티미디어학회논문지
    • /
    • 제19권7호
    • /
    • pp.1137-1145
    • /
    • 2016
  • The system for measuring the electrodermal activity (EDA) signal occurring at the sweet glands in the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer and the bio-potential measurement system (BPMS). Three experiments were performed using EDAMS. First, the linearity of the output voltage corresponding to the pressure being applied to an algometer was evaluated. The linearity of output voltage according to the pressure was 0.956. Second, the amplitude and the latency of the EDA signal at the left palm was obtained while applying the pressure stimuli to the left and right scapula. The latency of EDA signal was shorter whereas the amplitude of EDA signal was higher when the pressure applied was applied to the left scapula. Third, the amplitude and latency of the EDA was measured at left and right palm while increasing the pressure stimuli to the left scapula. The latency of EDA signal at left and right palm was decreased according to the intensity of pressure stimulus applied to the left scapula. However, the latency of the EDA signals did not show the linearity with respect to the pressure stimuli.

송전용 자기재 애자의 성능평가 및 가속열화시험 (Study on Performance and Aging Test of Porcelain Insulators for Transmission Line)

  • 한세원;조한구;박기호;이동일;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

매모그램 구조의 전기저항 영상법에서 정방향 모델의 고유전류 계산 알고리즘 (An Algorithm for Computing Eigen Current of Forward Model of Mammography Geometry for EIT)

  • 최명환
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.91-96
    • /
    • 2007
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present standard for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. A forward model of a simplified mammography geometry for EIT imaging was proposed earlier. In this paper, we propose an iterative algorithm for computing the current pattern that will be applied to the electrodes. The current pattern applied to the electrodes influences the voltages measured on the electrodes. Since the measured voltage data is going to be used in the impedance imaging computation, it is desirable to apply currents that result in the largest possible voltage signal. We compute the eigenfunctions for a homogenous medium that will be applied as current patterns to the electrodes. The algorithm for the computation of the eigenfunctions is presented. The convergence of the algorithm is shown by computing the eigencurrent of the simplified mammography geometry.

  • PDF

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System)

  • 김정철;이규선;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

소프트 스위칭 기법을 적용한 싱크로너스 양방향 DC-DC 컨버터 (Synchronous Bidirectional DC-DC Converter Applying Soft-Switching Technique)

  • 이동규;박남주;현동석
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.311-318
    • /
    • 2008
  • 본 논문은 소프트 스위칭 기법을 적용한 싱크로너스 양방향 DC-DC 컨버터를 제안한다. 제안된 컨버터는 싱크로너스 벅 컨버터를 병렬구성을 하여 인터리브드 기법을 통해 도통 손실을 줄이고, 하나의 공진인덕터를 사용한 ZVT-Cell을 적용함으로써 스위칭 손실을 최소화 하였다. 전 부하 범위에서 CCM(Continuous Conduction Mode) 으로 동작하고 ZVS가 성립되도록 하였으며, 전류주입 기법을 통해 넓은 출력전압 범위에서도 ZVS 조건을 만족하였다. 또한, 기존 싱크로너스 벅 컨버터의 데드타임(dead time)동안 발생하는 역병렬 다이오드의 도통손실 및 dv/dt, di/dt 발생을 저감하는 효과를 얻을 수 있다. 제안된 컨버터의 유효성은 실험을 통해서 검증하였다.