• Title/Summary/Keyword: body position

Search Result 1,474, Processing Time 0.026 seconds

Large displacement Lagrangian mechanics -Part I - Theory

  • Underhill, W.R.C.;Dokainish, M.A.;Oravas, G.Ae.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.1
    • /
    • pp.73-89
    • /
    • 1996
  • In Lagrangian mechanics, attention is directed at the body as it moves through space. The region occupied by the body is called a configuration. All body points are labelled by the position they would have if the body were to occupy a chosen reference configuration. The reference configuration can be regarded as an extra fictional copy where notes are kept. As the body moves and deforms, it is important to correctly observe the use of each configuration for computational purposes. The description of strain is particularly important. The present work establishes clearly the role of each configuration in total and in incremental forms. This work also details the differences between gradient and configurational calculus.

Do Obliquity and Position of the Oblique Lumbar Interbody Fusion Cage Influence the Degree of Indirect Decompression of Foraminal Stenosis?

  • Mahatthanatrakul, Akaworn;Kotheeranurak, Vit;Lin, Guang-Xun;Hur, Jung-Woo;Chung, Ho-Jung;Lokanath, Yadhu K;Pakdeenit, Boonserm;Kim, Jin-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.74-83
    • /
    • 2022
  • Objective : Oblique lumbar interbody fusion (OLIF) is a surgical technique that utilizes a large interbody cage to indirectly decompress neural elements. The position of the cage relative to the vertebral body could affect the degree of foraminal decompression. Previous studies determined the position of the cage using plain radiographs, with conflicting results regarding the influence of the position of the cage to the degree of neural foramen decompression. Because of the cage obliquity, computed tomography (CT) has better accuracy than plain radiograph for the measurement of the obliquely inserted cage. The objective of this study is to find the correlation between the position of the OLIF cage with the degree of indirect decompression of foraminal stenosis using CT and magnetic resonance imaging (MRI). Methods : We review imaging of 46 patients who underwent OLIF from L2-L5 for 68 levels. Segmental lordosis (SL) was measured in a plain radiograph. The positions of the cage were measured in CT. Spinal canal cross-sectional area (SCSA), and foraminal crosssectional area (FSCA) measurements using MRI were taken into consideration. Results : Patients' mean age was 69.7 years. SL increases 3.0±5.1 degrees. Significant increases in SCSA (33.3%), FCSA (43.7% on the left and 45.0% on the right foramen) were found (p<0.001). Multiple linear regression analysis shows putting the cage in the more posterior position correlated with more increase of FSCA and decreases SL correction. The position of the cage does not affect the degree of the central spinal canal decompression. Obliquity of the cage does not result in different degrees of foraminal decompression between right and left side neural foramen. Conclusion : Cage position near the posterior part of the vertebral body increases the decompression effect of the neural foramen while putting the cage in the more anterior position correlated with increases SL.

Applications to the Numerical Stamping Analysis of Tailor-welded Blanks (테일러드 블랭크의 스탬핑 성형해석에 관한 연구)

  • 이종민;최이천;최치수;유동진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.06a
    • /
    • pp.110-120
    • /
    • 1998
  • Tailor-welded blanks are made of two or more different blanks in thickness or material. So car body with tailor-welded blanks need not reinforcement panels. However in order to make stamping tools for tailor-welded blanks, die engineers should know about the exact position of the welding line after the part is drawn. The necessity of knowledge about the position of welding line needs forming simulation methodology as a prior step in tooling. Therefor some parts of the simulation methodology are proposed and compared with the experimental results.

Posture and Low Back Pain (일반적인 자세가 요통에 미치는 영향에 대한 고찰)

  • Jung, Mun-Boung;Lee, Geoun-Sung;Kang, Eun-Mi;Oh, Kyeong-Seok
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.4
    • /
    • pp.207-214
    • /
    • 1996
  • Main cause of low back pain is a poor posture. Most low back pains are due to a poor posture. The poor posture induces muscle tension and finaliy low back pain. The poor posture arehabitually trained from the childhood by the environmetal factors. In general, maintaining good posture during working and sleeping hours are the first line of defence against back pam. (1) Supine posture is the easiest posture that relaxes and fixes muscles. Supine posture is thus a starting position for on exercise. Lying down releases the weight pressures of head and shoulder and thus body can be relaxed and extended which are helpful for treating back pain. However, supine posture can increase the pressure in ribcage posture aspect and disphragram due to visceral oragans. (2) Sitting in one position for a long time results in fatigue and relaxation of spinal muscies. Finally, body strength is weakened and sitting posture will become poor. If this poor posture continues for a longer time, pain will be accompanied due to overelongation of muscle ligaments. The habitual poor posture could induce intervertebral disc distortion. If the intervertebral disc is damaged, sitting in one position or movement causes pain. (3) Abnormal lumbar curve induces the tention of abdominal muscle and paravertebral muscle groups as well as tention of lower limb muscle group connected to pelvis. For a person with weak body strength, muscle relaxation increases curvature in lumbar, chest and cervical regions. This will induce a pelvic anterior tilting of the imaginary line between A. S. I. S. and P. S. I. S. Hip joint extensor muscle acts on releasing the pelvic anterior tilting. Contrections of hamstring muscle and femoral muscle recover the imaginary line between A.S.LS. and P.S.I.S. from pelvic anterior tilting. thus, contraction of rectus abdominis muscle are required to maintain the normal lumbar curve.

  • PDF

Effective of Change Obesity Index by Specific Posture Exercise Using the Vibrator (진동기기를 이용한 자세별 운동이 비만에 미치는 영향)

  • Kim, Myung-Chul;Lee, Woo-Chul;Han, Seul-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.5
    • /
    • pp.757-762
    • /
    • 2013
  • The purpose of this study is to compare and evaluate the change of Body Mass Index(BMI) and body composition after having performed vibration exercise equipment at different ground conditions. The subjects were divided into 4 groups; Standing Group(SG)(n=10) and Horseback riding Group(BG)(n=10), Four point kneeling Group(FG)(n=10), Complex position Group(CG)(n=11). The period of intervention was for four weeks. Such as BMI and Waist Hip Ratio(WHR), Body Fat Ratio(BFR) were measured before and after exercise. The results from the above three measurements, only the CG showed significant differences. We were able to confirm that obesity change through complex position combines vibration exercise.

A Study on the Legal and Institutional Position and Role of Korean Medicine Doctors working at Public Health Center (보건소 근무 한의사의 법.제도적 지위와 역할에 관한 연구)

  • Im Jin-Taek;Lee Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.149-165
    • /
    • 2002
  • Objective : We proposed fundmental rules of prospective on legal and institutional position and role of Korean medicine doctors working at public health center. Methods : By the result of this research on the current situation, the grade and allowance given to the Korean medicine doctors working at public health center were different every self-governing body. Results : The reason the Korean Medicine Doctor can't serve as a regular order of 5th grade is that the 'The Enforcement Regulation about Administrative Organization and the Standard of Pixed Number of person of Self-Governing Body(지방자치단체의 행정기구와 정원기준등에 관한 규정 시행규칙)' prescribes the number of regular order of 5th grade is regulated within 7% among the number of regular order officials. But not appointing to office as the regular order of 5th grade infringes on the Constitution, the highest law. The reason the Korean Medicine Doctors can't be appointed to office as the regular order officials by the self-governing body is that 'The Enforcement Order of the Law of Preservation of good health of Local Area(지역보건법시행령)' prescribes the Korean Medicine Doctors are not indispensable to Public Health Center. But in fact, the Korean Medicine Doctors can execute many kinds of work such as medical examination or instructing house nursing. Conclusion : The Korean Medicine Doctors working at Public Health Center serve at low positions as daily use or common use, not receiving a regular order. All laws including the Constitution(헌법), the Medical Services Law(의료법), the Law of Preservation of good health of Local Area(지역보건법), the National Public Service Law(국가공무원법), the Local Public Service Law(지방공무원법) and the Law of Higher Education Law(고등교육법) describe that the Korean Medicine Doctors and the Western Medicine Doctors are equal to their position and right.

  • PDF

Nonlinear Analysis of Underwater Towed Cable Using Robust Nodal Position Finite Element Method (강건 절점위치 유한요소법을 이용한 수중 예인 케이블의 비선형 거동해석)

  • Lee, Euntaek;Go, Gwangsoo;Ahn, Hyung Taek;Kim, Seongil;Chun, Seung Yong;Kim, Jung Suk;Lee, Byeong Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.5
    • /
    • pp.388-399
    • /
    • 2016
  • A motion analysis of an underwater towed cable is a complex task due to its nonlinear nature of the problem. The major source of the nonlinearity of the underwater cable analysis is that the motion of the cable involves large rigid-body motion. This large rigid-body motion makes difficult to use standard displacement-based finite element method. In this paper, the authors apply recently developed nodal position-based finite element method which can deal with the geometric nonlinearity due to the large rigid-body motion. In order to enhance the stability of the large-scale nonlinear cable motion simulation, an efficient time-integration scheme is proposed, namely predictor/multi-corrector Newmark scheme. Three different predictors are introduced, and the best predictor in terms of stability and robustness for impulsive cable motion analysis is proposed. As a result, the nonlinear motion of underwater cable is predicted in a very efficient manner compared to the classical finite element of finite difference methods. The efficacy of the method is demonstrated with several test cases, involving static and dynamic motion of a single cable element, and also under water towed cable composed of multiple cable elements.

A Convergence Study on Flow Analysis According to the Position of Radiator Inside Car (자동차 내부에서의 라디에이터 위치에 따른 유동해석에 관한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.321-326
    • /
    • 2019
  • As the use of public transportation increases, many researches are being carried out to increase the fuel economy of car. The goal of this study is to design a front body in order to increase the fuel economy of car through three models of cars. All models were designed with CATIA program and the flow analyses on the air outside car by model were carried out with ANSYS program. At the driving speed of 90km/h, the longer the body, the less air resistance it received. So, it is thought that there is the effect to increase fuel economy. Through this study, it can be helpful to design the front car body that can maximize train efficiency. By utilizing the design data on flow analysis according to the position of radiator inside car in this study, the esthetic sense can be given by being grafted onto the real automotive part.

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Expression Types and Characteristics of Body Parts Shown in Modern Fashion Design: Focused on from 2001S/S to 2008S/S (현대패션디자인에 나타난 신체부위의 표현유형과 특성 : 2001S/S$\sim$2008S/S를 중심으로)

  • Kim, Sun-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.47 no.8
    • /
    • pp.25-35
    • /
    • 2009
  • This study analyzed expression types and characteristics of modern fashion designs using body parts. The research was conducted based on a literature review and empirical research of fashion magazines published in Korea and other countries from 2001 to 2008. Four fashion statements predominated. Most frequently, body parts presented in modern fashion design, included realistic expressions, simplification, anatomic expression and a mixture with other patterns and logos. A body part, such as an eye, a lip, a hand or a chest was characteristically located in an unfamiliar position, as part of modern fashion design using body parts. Other parts and surrealistic images were shown with accessories utilizing body shapes. Second, amusing images were emphasized with humorous expressions, including simplification of body parts, childish decorations, fairy tale illusions and cartoon factors. Third, erotic images were presented with a more realistic expression of a partial image of a female body part, such as a lip or a tongue. Fourth, the use of facial images of celebrities in modern fashion design showed the phase of the times and the characteristic utilization of pop art as an image.