• Title/Summary/Keyword: body image distortion

Search Result 64, Processing Time 0.022 seconds

A Study of Tube Angle and Patient's Rotation Angle in Scapular Y View (어깨뼈 후전사방향촬영에서 Tube 각도와 환자의 회전각도 관한 연구)

  • Ahn, ByeoungJu;Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.271-275
    • /
    • 2013
  • Shoulder bone scan everyday life, sports activities at the side of the shoulder joint, or applying strong force in the lateral occurs. Mainly on upper arm abduction, temple, other rotational dislocation of the shoulder joint gahaejyeo as useful for observing the presence or absence of lesions is used. Shoulder PA oblique projection prevent distortion of the image due to the angle and the most useful diagnostic radiological investigate shooting angle. Shoulder blade body and the acromion and coracoid process Y-view is formed characters. $10^{\circ}$ angle between the shoulder blades and the acromion is the obstruction. $20^{\circ}{\sim}25^{\circ}$ to the Y-view of the humerus head looks superimposed, the position of the shoulder joint and seemed appropriate. $35^{\circ}$ of the humerus head superimposed on the Y-view, but above the humerus head and shoulder joints were distorted. When $45^{\circ}$ elevation observed on the side of the best has come Y-view also acromion and coracoid process is finished.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

A Study of Data Management Methods through Shake Correction of Underwater Investigation Using High Resolution Side Scan SONAR (흔들림 보정을 통한 고해상 사이드스캔소나의 데이터 관리기법 연구)

  • Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul;Choi, Sang-Sik;Lee, Heung-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.94-100
    • /
    • 2017
  • In the case of the side scan sonar operated by the towing method, the underwater structure electric jig was developed because there is a difficulty in the cross-sectional survey that the user wants when conducting the survey. However, in the case of the sound wave photographing method using the electric jig, since the boat and the sonar behaves as one body, data distortion has occurred due to various problems according to working environment, such as, the rolling phenomenon of the boat due to the wave and the fluctuation of the sonic image due to the inoperability of the boat driver. Therefore, in order to solve the image blurring caused by the operation of the equipment for underwater survey of the existing side scan sonar, in this research, the program was supplemented to enable the shake correction by attaching the shake correction sensor and developing the shake correction algorithm. In order to verify the improvement of the sonar data resolution, the sonic images before and after the shake correction were collected through on-site investigation and the analysis of the sonic image data acquired by a diver measuring the actual damage length and depth. This study is expected to contribute to the development of sonar imaging technique of the underwater surface of the structure and bed surface of the sea or a river using the side scan sonar in the future.

The Grotesque Fashion in modern Fashion (현대 패션에 나타난 그로테스크)

  • 최정화;유영선
    • Journal of the Korean Society of Costume
    • /
    • v.40
    • /
    • pp.151-170
    • /
    • 1998
  • The purpose of this study is to examine the value of grotesque fashion and to predict the future fashion trend. The grotesque originates the formative art. It emerges towards of a century or transitional period in most case. In particular, it was used as the expressive method of an individual's inside and a satire on society through the work of artists in the Middle Age, the renaissance, the sym-bolism, the dadaism, the surrealism, the pop art, the technology art, and the post-modernism, etc. The grotesque in fashion is represented in the work of avant-garde fashion designers who lead the high fashion. The grotesque fashion which was combined with an image of non-formality, non-rationality, an absurdity and reality. It has been begun shape of female dress in the renaissance. Afterwards, it was represented in extremely exaggerated and distorted pop art, hippies' fashion in the 1960's. In the 1970's, it was reflected in genderless rock star and destructive punk fashion. It was also represented in the androgynous fashion which was combined with both sexes, the goth/gothic fashion which was expressed with a realistic and fanciful shape and the tattoo of skin-head in the 1980's. In the 1990's, the grungy look which was dirty and the cyber punk fashion. In general, it was also expressed by the avant-garde fashion designers. To sum up, a grotesque fashion which is expressed by experimental designers is classified into four shapes. 1, Union of some extraneous is expressed as different kinds of fashion theme, such as abnormality of texture, uses of surrealistic elements and chaos of sex. Although it appears that the abnormal union of grotesque has only discord and collision, it also shows a feeling of freedom for the tension. 2. Introduction of real and fanciful image is expressed as a cyborg, realistic description of disgusting animal skin and aggressive shape. Especially, it is worth while to notice Tierre Mugler and Alexander Macqueen's work which expressed the shape of mingling human of Middle Age. 3. distortion or exaggeration is expressed as an unformed shape, the exaggeration of a clothing size, the abnormal exaggeration of human body and the ignorance of clothing form. 4. Introduction of a disgusting image is expressed as an extremity of reality, motifs of death, clothing material of disgusting hair and the ostentation of sex. Motto which leads modern fashion is something new and shocking. The grotesque fashion is an expression of eagerness for something new. It often show something ironic in the form of humor which is embedded in an abnormal and shocking pattern. The grotesque fashion is represented as an extreme beauty. It will stand as an important element of the future fashion and as a particular style with the change and fluidity.

  • PDF

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

Analysis on Characteristics of Representation of Surrealism on Fantasy Online Game's Character (판타지 온라인 게임의 캐릭터에 관한 초현실주의의 표현 특징 분석)

  • Kim, Kyoung-Nam;Lee, Myoun-Jae
    • Journal of Korea Game Society
    • /
    • v.5 no.4
    • /
    • pp.3-12
    • /
    • 2005
  • Many works have been published with using surrealism techniques among the representation characteristics of media space of video and art. It has begun to research on these work. But many of these researches have not cover surrealism techniques in game graphic. So, in this paper, we have analyzed representation characteristics of fantasy online game's character using surrealism techniques in surrealism. In result, there are means to express nonexistent image in real world in surrealism by using such as collage of parts of body, animals, and other object, deformation, and distortion. Also, these methods have been used in game characters of online game based on fantasy. We analyzed on characteristics of fantasy game's character in aesthetic point view. It should be profitable for making creative and favorable game characters and making creative game graphic by increasing the possibility of art techniques usage.

  • PDF

The Effect of School Health Education based on Life Skill Training on Middle School Students' Health Knowledge, Attitude, and Behavior (생활기술훈련 기반 학교 보건교육이 중학생의 건강지식, 태도, 실천 행위에 미치는 영향)

  • Yi, Eun Yeong;Kim, Chung Nam
    • Journal of the Korean Society of School Health
    • /
    • v.28 no.3
    • /
    • pp.211-219
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the effect of health education based on life skill training (LST) on middle school students' health knowledge, attitude, and behavior. Methods: For this study, 961 middle school students, residing in Seoul, Korea, were selected. The students received health education one day a week for 7 weeks from September 1, 2014 to October 25, 2014. Before and after the whole education program, the students filled out questionnaires surveying on their health knowledge, attitude, and behavior. Excluding inappropriate data, the data of 843 students was analyzed through Paired t-test. Results: After the education program based on LST, there were statistically significant increases in the scores for knowledge about drinking, body image distortion, good eating habits, right usage of smartphone, and prevention of smartphone addiction (p<.05). There were also statistically significant increases in the scores for attitude toward smoking, drug, good eating habits and prevention of smartphone addiction (p<.05). There were statistically significant increases in the scores for behavior regarding drug, good eating habits, right usage of smartphone and prevention of smartphone addiction (p<.05). Conclusion: Health education based on life skill training was especially effective in improving the subjects' scores for health knowledge, attitude, and health behavior. Therefore, various and systemic LST educational programs should be developed and implemented and their effects should be evaluated in further studies.

An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application (PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석)

  • Park, Kyeongjin;Kim, Hyoungtaek;Lim, Kyungtaek;Cho, Minsik;Kim, Giyoon;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

Implementation of User Gesture Recognition System for manipulating a Floating Hologram Character (플로팅 홀로그램 캐릭터 조작을 위한 사용자 제스처 인식 시스템 구현)

  • Jang, Myeong-Soo;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.143-149
    • /
    • 2019
  • Floating holograms are technologies that provide rich 3D stereoscopic images in a wide space such as advertisement, concert. In addition, It is possible to reduce the 3D glasses inconvenience, eye strain, and space distortion, and to enjoy 3D images with excellent realism and existence. Therefore, this paper implements a user gesture recognition system for manipulating a floating hologram characters that can be used in a small space devices. The proposed method detects face region using haar feature-based cascade classifier, and recognizes the user gestures using a user gesture-occurred position information that is acquired from the gesture difference image in real time. And Each classified gesture information is mapped to the character motion in floating hologram for manipulating a character action. In order to evaluate the performance of the proposed user gesture recognition system for manipulating a floating hologram character, we make the floating hologram display devise, and measures the recognition rate of each gesture repeatedly that includes body shaking, walking, hand shaking, and jumping. As a results, the average recognition rate was 88%.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF