• 제목/요약/키워드: body area

검색결과 3,860건 처리시간 0.032초

Performance Analysis of Multiple-Hop Wireless Body Area Network

  • Hiep, Pham Thanh;Hoang, Nguyen Huy;Kohno, Ryuji
    • Journal of Communications and Networks
    • /
    • 제17권4호
    • /
    • pp.419-427
    • /
    • 2015
  • There have been increases in the elderly population worldwide, and this has been accompanied by rapid growth in the health-care market, as there is an ongoing need to monitor the health of individuals. Wireless body area networks (WBANs) consist of wireless sensors attached on or inside the human body to monitor vital health-related problems, e.g., electrocardiograms (ECGs), electroencephalograms (EEGs), and electronystagmograms (ENGs). With WBANs, patients' vital signs are recorded by each sensor and sent to a coordinator. However, because of obstructions by the human body, sensors cannot always send the data to the coordinator, requiring them to transmit at higher power. Therefore, we need to consider the lifetime of the sensors given their required transmit power. In the IEEE 802.15.6 standard, the transmission topology functions as a one-hop star plus one topology. In order to obtain a high throughput, we reduce the transmit power of the sensors and maintain equity for all sensors. We propose the multiple-hop transmission for WBANs based on the IEEE 802.15.6 carrier-sense multiple-access with collision avoidance (CSMA/CA) protocol. We calculate the throughput and variance of the transmit power by performing simulations, and we discuss the results obtained using the proposed theorems.

다발성 골수증 (REPORT OF A CASE OF MULTIPLE MYELOMA)

  • 최은숙;고광준
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.389-397
    • /
    • 1993
  • This is a report of multiple myeloma occurred in the left mandibular body and skull. 66-year-old patient was referred to our hospital with a complaint of painful swelling on the left mandibular body area. The author diagnosed it as a multiple myeloma by the clinical examination, radiographic findings, laboratory findings and the histopathological findings. The purpose of this report is to aid in the diagnosis of multiple myeloma and to aid to differentiate it from malignant tumours. The characteristic features are as follows: 1. In clinical examination, painful swelling was observed in left mandibular body area. 2. In radiographic findings, radiograms showed relatively ill-defined radiolucency without sclerotic border in left mandibular body area. And also represented multiple punched-out radiolucency in the skull and pathologic fracture of vertebral body on lumbar 3 level. 3. In histopathologic findings, infiltration of abnormal plasma cells was observed. 4. In laboratory findings, decreasing of albumin/globulin ratio, hypercalcemia, renal impairment was observed, but we could not find the Bence-Jones protein in urin.

  • PDF

강원지역 초등학생의 인식체형에 따른 영양지식, 식생활태도, 식이자기효능감과의 관련성 (Relationships among Eating Behavior, Dietary Self Efficacy and Nutrition Knowledge according to the Perceived Body Shape of Elementary School Students in Gangwon Province)

  • 원향례
    • 한국지역사회생활과학회지
    • /
    • 제19권4호
    • /
    • pp.707-719
    • /
    • 2008
  • This study was carried out to find the relationship among dietary behavior, dietary self efficacy and nutrition knowledge according to the perceived body shape of the 5th and 6th grade elementary students in Gangwon Province and found out their relationships. The results are as follows; The factors that showed significant difference according to perceived body shape were gender, father's education level, the number of siblings, birth order, obesity of parents and siblings and ideal body shape. For the perceived body shape, the students answered generally normal(48.9%), slightly fat(27.9%), thin(16.5%) and very fat(6.7%). Out of total students 76.5% of them were not satisfied with their body shape such that satisfactory(23.5%), want to lose weight(61.4%) and want to increase weight(15.1%). The score of eating behavior showed significant difference between perceived body shape on such questions as eating speed(p<0.001), frequency of fatty food intake(p<0.001), adequate intake quantity(p<0.001), balanced diet(p<0.05), frequency of going out to eat(p<0.001). The score of diet self efficacy showed significant difference in the area of general habit on such questions as whether to eat slowly together with friends (p<0.001), whether to eat adequate quantity(p<0.001), whether not to have snacks after dinner(p<0.001). And in the area of food selection it showed significant difference on such questions as to select ice cream in stead of yoplait(p<0.001). In the area of social circumstance it showed significant difference on such questions as to reject the food(p<0.01) and to restrain food in birthday party or holiday(p<0.05). In the area of emotional status it showed significant difference on the question about food restrain when boring and depressed(p<0.05 respectively). The score of nutrition knowledge showed significant difference according to the perceived body shape on such questions as total score(p<0.01), five basic food group(p<0.05), snack and body weight(p<0.001), calcium function(p<0.01). It showed perceived body shape co-related with the nutrition knowledge(p<0.01). In summary, the perceived body shape for the highly eating behavior was generally normal, for the highly dietary self efficacy was slightly fat, and for the highly nutrition knowledge was also slightly fat.

  • PDF

무선 인체통신 네트워크를 위한 복합 우선순위 MAC 기법 (Hybrid Priority Medium Access Control Scheme for Wireless Body Area Networks)

  • 이인환;이건우;조성호;조성래
    • 한국통신학회논문지
    • /
    • 제35권9B호
    • /
    • pp.1305-1313
    • /
    • 2010
  • 지난 몇 년간 무선 개인 거리 네트워크는 (WPAN)는 다양한 건강관리 응용분야에서 널리 연구되어왔다. 그러나, 하드웨어 장치의 한계성으로 인해 WPAN의 효용성에 대한 문제점이 도출되었다. 이를 개선하고자 무선 인체통신 네트워크 (WBAN: Wireless Body Area Network)의 개념이 탄생하였고 이러한 WBAN을 위하여 다용도의 MAC계층 프로토콜을 설계할 필요성이 대두됐다. 더불어, 환자에게 긴급 상황이 발생했을 경우, 최종 목적지로 긴급메세지가 전해지는 우선권을 가진 메커니즘이 필요하게 되었다. 본 논문은 WBAN을 위한 복합 우선순위 MAC이라 일컬어지는 우선순위 메커니즘에 대해 기술한다. 또한, 시뮬레이션의 확장을 통해, 평균 패킷 지연 시간을 최소화 할 수 있는 MAC 프로토콜을 제안한다. 이들을 통해, 환자에게 긴급 상황이 발생했을 때 충분한 도움시간과 의학적 치료지원 시간이 제공 될 수 있도록 한다. NS-2를 기반으로 한 성능평가 시뮬레이션을 통해, 우리의 복합 우선순위 MAC의 뛰어난 성능과 유용성을 입증한다.

3D모델을 이용한 비만체형 여성의 허리-배 부위 패턴 특성 연구 (Pattern Development of Waist / Abdominal Area of Obese Womem Using 3D Geometrical Model)

  • 김소영;홍경희
    • 한국의류학회지
    • /
    • 제29권7호
    • /
    • pp.1018-1026
    • /
    • 2005
  • Recent development of 3D scanner and software is regarded as a promising method of acquiring replicas from human body indirectly. It would be very helpful if we could predict the characteristics of 2D pattern from the simple parameters related to 3D shape for ordinary user. Therefore, in this study, investigation of 2D pattern of waist/abdominal area from the 3D geometrical model was conducted for the pattern development of waist nipper. To create body models and develop the surface of them, one ortho commonly used CAD/CAM program, IDEAS(UGS-plm solutions, USA) was used. As for the size of the models, the width, thickness, and circumference ranges of adult women's torso reported in National Anthropometric Survey of Korea (1997) were used as a standard model. Seven size variations were made by changing the width of the waist only, from 19 cm to 40 cm. Therefore, simulated body models include not only the normal body but also obese body who has wider waist and abdomen width than hip width. As results, it was found that the curvature of the unfolded 2D pattern around the abdominal area decreases as the waist width increases. As the width of the waist increases more and more, so that the comparative ratios around the torso becomes in abnormal ranges, there appears inflection points and the direction of curvature was changed. 2D Patterns obtained in this research were quantified by curvature, length of the curve and angle of deflection in the reference frame box for the convenience of the actual pattern making process. It was also possible to find that the shape of patterns of abnormal body resulted in a quite interesting change in the curves of 2D pattern, which could be applied to the custom made waist nipper for obese women.

편마비 환자의 트레드밀과 체중지지의 트레드밀 훈련이 균형능력 및 보행능력에 미치는 영향 (The Effect of Treadmill and Body Weight Support Treadmill Training on Balance and Gait Ability in Hemiplegia Patients)

  • 김성철;허영구
    • 대한물리치료과학회지
    • /
    • 제25권1호
    • /
    • pp.31-43
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate and to verification of changes that the effect of treadmill and body weight support treadmill training on balance and gait ability for sub-acute stroke patients during 4 week. Method: 16 subjects who was diagnosed stroke were divided into 2 groups(8-treadmill training group, 8-body weight support treadmill group) by randomized control trial. Both training programs were consisted with 40 minuted, 5 times a week for 4 weeks and after training programs. Analysis: We analysed effects and changes on balance and gait ability. Analyses were performed using PASW ver. 18.0 and results were reported as mean ${\pm}$ standard deviation (S.D.). To investigate within group comparisons and to verification on effects of exercise, we did paired t test and repeated measured ANOVA test. Significance was set at p<.05. Result: Both training programs showed positive changes in Limit of Stability but significant results which is area of hemiside, area of intact side, area of posterior, total area were reported in body weight support treadmill training group. Changes of Berg Balance Scale was significantly increase and it had significant correlation between groups. Changes of 6 Minutes Walking Test was significant increase in both groups but there was no significant changes on Foot print and Romberg test. Conclusion: After considering all factors, both training programs showed effect on improvement of balance and gait ability in sub-acute stroke patients, but body weight support treadmill training group had better improvement in dynamic balance than treadmill training group. For the increase of balance and gait ability in sub-acute stroke patients, we need to continues study on difference of treadmill and body weight support treadmill and then we will give stroke patients a better satisfaction if we develop and provide a rehabilitation program for improvement of balance and gait ability.

무선 신체 망에서 망의 생존시간을 보장하는 에너지 인지 망 구성 관리 기법 (Energy-Aware Configuration Management with Guaranteed Lifetime of Network in Multi-hop WBAN)

  • 서수호;나재욱;박종태
    • 한국통신학회논문지
    • /
    • 제34권10B호
    • /
    • pp.981-987
    • /
    • 2009
  • 최근 유비쿼터스 헬스케어 서비스를 위한 무선 신체 망에 대한 연구가 IEEE 등을 중심으로 연구가 활발히 진행되고 있다. 무선 신체망은 전력제한 및 생체특성을 반영하여 멀티 홉 통신 기반의 부모노드 및 자식노드로 구성된 트리형태로 구성되는 경우가 많다. 이 경우 기존의 센서 네트워크와 달리 빈번한 신체의 움직임으로 망에 연결되어 있는 노드의 연결이 끊어질 가능성이 높으며 각 노드의 전력소모 제한으로 인해 각 노드에서 처리 가능한 노드 연결 수에 제한이 있다. 본 연구에서는 노드가 망과 연결이 끊어졌을 경우 노드가 전송할 패킷의 우선순위를 고려하여 QoS를 만족하면서 최적의 부모 노드를 선택하는 휴리스틱 알고리즘을 제안한다. 시뮬레이션을 통해 제안한 알고리즘의 성능분석을 하였으며 그 결과 본 연구에서 제안한 알고리즘이 망의 생존시간이 더 길다는 것을 확인하였다.

차량 드로틀 보디 전장부품의 품질관리 성능시험 알고리즘 개발 (Development of Algorithm of Surge Test for Quality Control on Electrical Parts of Throttle Body in Automobiles)

  • 손재환;김태한
    • 한국산업융합학회 논문집
    • /
    • 제9권1호
    • /
    • pp.67-72
    • /
    • 2006
  • This study is on the development of algorithm of surge test for quality control on electrical parts of throttle body in automobiles with internal combustion engine, not only to know its condition to be good or not, but also jugding its condition to be classified into six types. To know whether its condition to be good or not, comparing and analyzing between two waveforms generated from master and test coil of throttle body. If test net area is below 20% of master area, the condition of test coil is good. By analyzing test coil waveform to master coil waveform, the condition of test coil into winding badness, insulation badness, layer and corona discharge, short badness should known. Therefore quality control system on electrical parts of throttle body should be developed.

  • PDF

중국(中國) 절강성(浙江省) 영파지역(寧波地域) 남성(男性)의 체형연구(體形硏究) (Body Types of Adult Males in the Ningbo Area of Zhejiang Province in China)

  • 심부자
    • 패션비즈니스
    • /
    • 제11권1호
    • /
    • pp.108-124
    • /
    • 2007
  • Body measurement was held for the subjects of Chinese adult males in their 20s through 40s residing in the Ningbo area of Zhejiang Province in order to provide body type information and raise the fit of clothing products for the advancement into the Chinese market. The following sums up the analysis of body types based on body measurement: 1. Seven factors to compose body types were produced from the analysis of males in their 20s, explaining 76.07% of variables and representing 3 types according to cluster analysis. Type 1 was H-b and appeared as much as 32.14%. Type 2, semi X-d, was 40.81%, while Type 3, A-i, had 27.04%. 2. Eight body type composing factors were extracted from the analysis of men in their 30s and 40s. The factors explained 76.77% of all the variables and represented 4 types according to cluster analysis. Type 1, H-d, had the appearance rate of 18.47%; Type 2, H-b, 40.84%; Type 3, Y-i, 27.71%; and Type 4, semi X-s, 11.95%.

고주파요법이 부분비만치료에 미치는 영향 (Effects of High Frequency Therapy on Localized Obesity)

  • 신승우;최영민;심우진;이형철;김길수
    • 한방비만학회지
    • /
    • 제6권2호
    • /
    • pp.75-83
    • /
    • 2006
  • Objectives : This study was performed to identify the effects of high frequency therapy on localized obesity. Methods : This trial was carried out in 12 volunteers. Volunteers were divided into 3 groups; upper arm group (n=4), thigh group (n=4) and abdomen group (n=4) according to local obesity type. Body weight and body fat were measured by Inbody 720 and CT (Computed Tomography) immediately before and following high frequency therapy. Diathermy was performed twice a week for 4 weeks for a total of 8 treatments. Results : In the upper arm group, body weight, body fat mass, fat area by CT scan and circumference were increased after treatment but not significantly (p>0.05). In the thigh group, body weight, body fat mass and circumference were decreased and fat area by CT scan was increased but both not significantly (p>0.05). In the abdomen group, significant differences were not found despite decreases in body weight, body fat mass, visceral fat and subcutaneous fat after diathermy (p>0.05). Conclusions : There was no significant effects of high frequency therapy on localized obesity.

  • PDF