• 제목/요약/키워드: blood vessel elasticity

검색결과 16건 처리시간 0.028초

Comparison of Vessel Elasticity according to Risk Factors for Coronary Artery Disease, and the Mediating Effects of Treatment Compliance among Patients with Percutaneous Coronary Intervention (관상동맥질환 위험정도와 혈관탄성의 관계에서 치료지시이행의 매개효과: 경피적 관상동맥 중재술 환자 대상)

  • Yeo, Ga Ram;Sung, Kyung Mi
    • Journal of East-West Nursing Research
    • /
    • 제22권1호
    • /
    • pp.32-40
    • /
    • 2016
  • Purpose: This study aimed to provide basic data for vascular health of patient who underwent percutaneous coronary intervention (PCI) by verifying the mediating effect of compliance in the relationship between risk level of coronary artery disease (CAD) and blood vessel elasticity. Methods: This is a descriptive study with 115 patients, who underwent the PCI a year ago and visited in the cardiology department from January to March, 2015. The risk level of CAD, blood vessel elasticity and the compliance were measured. For data analysis, SPSS/WIN 21.0 and AMOS (IBM) 21.0 were used. Results: There were a positive correlation with blood vessel elasticity score (i.e. inelasticity of the blood vessel wall) (r=.189) and a negative correlation with compliance (r=-.658) in mediating effect of risk level of CAD. There was a negative correlation between compliance and blood vessel elasticity (r=-.482). The direct effect (${\beta}=-.226$), indirect effect (${\beta}=.415$) and total effect (${\beta}=.186$) of mediating effect of risk level of CAD on blood vessel elasticity were significant. Compliance had a partial mediating effect of risk level of CAD on blood vessel elasticity. Conclusion: The results of this study suggest that managing and preventing moderating effect of risk level of CAD on compliance is helpful in restoring blood vessel elasticity.

Effects of Aerobic Exercise on Middle-aged Male Smokers' Blood Vessel Health (유산소 운동이 중년흡연남성의 혈관건강에 미치는 영향)

  • Kim, Jong-In;Jeong, Hae-Cheon;Won, Jun-Yeon;Ka, Sung-Soon;Oh, Bok-Sil
    • Journal of Digital Convergence
    • /
    • 제12권4호
    • /
    • pp.349-356
    • /
    • 2014
  • This research is aimed to prove if harmful effects of smoking, as the main reason for recently elevated blood vessel disease, could be reduced by aerobic exercise, and identify the positive effects of the aerobic exercise on smokers' blood vessel health(blood pressure, pulse pressure, and blood vessel elasticity. Experiments were performed on 40 male smokers aged between 40 and 55, which was equally divided into two groups of Aerobic Exercise Group (AEG) and Non Exercise Group (NEG). After measuring each group's blood pressure, pulse pressure, and blood vessel elasticity, AEG practiced aerobic exercise program for 50 minutes for each trial, three times a week, sustaining 12 weeks while NEG continued daily-life patterns without any special treatment. In 12 weeks, blood pressure, pulse pressure, and blood vessel elasticity of both groups were measured as the same way. As a result, the difference of systolic blood pressure between the two groups was not significant, while that of diastolic blood pressure was meaningful. The difference of pulse pressure between the two groups was meaningful, and that of blood vessel elasticity was also meaningful in all measuring points including left hand, right hand, left foot and right foot. As a consequent, it was found that aerobic exercise had positive effects on middle aged male smokers' blood vessel health.

Effects of circulation exercise on health-related physical fitness, blood pressure and blood vessel elasticity of obese women in the 50s (순환운동이 50대 비만중년여성의 건강체력, 혈압 및 혈관탄성도에 미치는 영향)

  • Kim, Yeon-Joo;Kim, Ji-Hyeon;Ha, Soo-Min;Kim, Jung-Sook;Kim, Jong-Won;Yoon, Byeong-Kon;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • 제34권4호
    • /
    • pp.756-768
    • /
    • 2017
  • The subjects for the study were twenty four obese women(50's) composed of the exercise group(n=12) and to a "no exercise" control group(n=12). The variables of health-related fitness, blood pressure, and blood vessel elasticity where measured in all the subjects before the start of the training program and after at the end of the 8 weeks circuit training. The test data were analyzed by t-test, paired t-test, and alpha level of p<.05 was set for all tests of significance. Health-related fitness was exercise group, the BMI had significantly decreased, and the 20m shuttle run, sit-ups and sit-and-reach had significantly increased. Blood pressure was exercise group, the systolic blood pressure, and diastolic blood pressure had significantly decreased. Also, after the circuit training program, the exercise group had significantly higher diastolic blood pressure than did the control group. blood vessel elasticity was exercise group, the blood vessel elasticity had significantly decreased. And exercise group had significantly higher diastolic blood vessel elasticity than did the control group. In conclusion, BMI, systolic blood pressure, and diastolic blood pressure had significantly decreased, but 20 m shuttle run, sit-ups and sit-and-reach had significantly increased in the combined exercise group after the 8 weeks circuit training. Therefore, regular and continuous circuit training were effective in improving the body composition, blood pressure, blood vessel elasticity and health-related fitness.

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.

Estimating Material Parameters of Rubber-liked Material Similar to Biomaterial (생체 유사재료를 설명하는 물질 상수 추정)

  • Kang, Taewon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권1호
    • /
    • pp.45-49
    • /
    • 2013
  • It is important to have a well developed strain energy function in order to understand the mechanical behavior of biomaterial like the blood vessel of artery. However, since it is not possible to have a complete form of strain energy function of artery, theoretical framework describing the behaviour of Rubber-like material which is similar to blood vessel is applied to infer useful forms of strain energy function of biomaterial. Based on Chuong-Fung model and Mooney-Rivlin model, material parameters are estimated based on experimental data. From the results, it can be inferred that the estimated parameters can be used to explain the difference of mechanical characteristics between normal vessel and vessel with stent.

Tensile Characteristics and Behavior of Blood Vessels from Human Brain in Uniaxial Tensile Test

  • Suh, Chang-Min;Kim, Sung-Ho;Ken L. Monson;Werner Goldsmith
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1016-1025
    • /
    • 2003
  • The rupture of blood vessels in the human brain results in serious pathological and medical problems. In particular, brain hemorrhage and hematomas resulting from impact to the head are a major cause of death. As such, investigating the tensile behavior and rupture of blood vessels in the brain is very important from a medical point of view. In the present study, the tensile characteristics of the blood vessels in the human brain were analyzed using a quasi-static uniaxial tensile test, and the properties of the arteries and veins compared. In addition, to compare the tensile behavior and demonstrate the validity of the experimental results, blood vessels from the legs of pigs were also tested and analyzed. The overall results were in accordance with the histological structures and previous medical reports.

Theoretical Framework For Describing Strain Energy Function on Biomaterial (생체재료를 설명하는 스트레인 에너지 함수에 대한 이론적 고찰)

  • Kang, Taewon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권1호
    • /
    • pp.50-55
    • /
    • 2013
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. However, theoretical framework to describe and quantify the behaviour of blood vessel was not well established so far. For studying the biomechanical behavior of artery, Rubber-liked material which is similar to passive artery is selected since conventional theoretical interpretation is very limited to understand and predict the behavior of biomaterial. Rubber-like material is assumed to be very similar to artery and has properties of isotropy, homogeneity and is undergoing large deformation. Based on this assumption, stress developed on Rubber-like material is described by strain energy function and strain invariants which are required to understand the nonlinear elastic behavior of biomaterial. The descriptor which would be used for understanding the biomechanical behavior of artery is studied in this work.

NUMERICAL ANALYSIS OF BLOOD FLOW DYNAMICS AND WALL MECHANICS IN A COMPLIANT CAROTID BIFURCATION MODEL (혈관 유연성을 고려한 경동맥 분기부 모델 혈류역학 해석)

  • Nguyen, T.M.;Lee, S.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.500-503
    • /
    • 2011
  • Blood flow simulations in an idealized carotid bifurcation model with considering wall compliance were carried out to investigate the effect of wall elasticity on the wall shear stress and wall solid stress. Canonical waveforms of flowrates and pressure in the carotid arteries were imposed for the boundary conditions. Comparing to rigid wall model, generally, we could find an increased recirculation region at the carotid bulb and an overall reduced wall shear stress. Also, there was appreciable change of flowrate and pressure waveform in longitudinal direction. Solid and wall shear stress concentration occurs at the bifurcation apex.

  • PDF

Rubber-liked Biomaterial Experimental Setup based on Nonlinear Elasticity Theory (비선형 탄성이론에 기초한 혈관류 생체재료 실험장치)

  • Kang, Tae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제27권6호
    • /
    • pp.90-97
    • /
    • 2010
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. Using computer-controlled experimental system, the experiment can acquire data such as inner pressure, axial load, diameter and axial gauge length without contacting the specimen. Rubber-liked material which is similar to passive artery was selected as pseudo-biomaterial. Deformations are measured for pressure-diameter curves. The data were collected and stored online to be used in the feedback control of experimental protocols. Finally, the illustrative data obtained from the experimental system were presented and the system shows that strain invariants are controlled to understand the nonlinear elastic behavior of biomaterial which is involved with strain energy function.

The Effects of Wall Elasticity on Wall Shear Rate of a Divergent Tube (Vascular Graft) (벽 탄성도가 확장관(인조혈관) 벽 전단변형률에 미치는 영향)

  • Rhee, Kye-Han;Lee, Sang-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제23권6호
    • /
    • pp.912-921
    • /
    • 1999
  • Shear stress acting on the arterial wall by blood flow is an important hemodynamic factor influencing blocking of blood vessel by thickening of an arterial wall. In order to study the effects of wall elasticity on the wall shear rate distribution in an artery-divergent graft anastomosis, a rigid and a elastic model are manufactured. These models are placed in a pulsatile flow loop, which can generate the desired flow waveform. Flow visualization method using a photochromic dye is used to measure the wall shear rate distribution. The accuracy of measuring technique is verified by comparing the measured wall shear rate in the straight portion of a model with the theoretical solution. Measured wall shear rates depend on the wall elasticity and flow waveform. The mean and maximum shear rate in the elastic model are lower than those in rigid model, and the decreases are more significant near the end of a divergent tube. The reduction of mean and maximum of wall shear rate in an elastic model are up to 17 percent.