• 제목/요약/키워드: blood chemical analysis

검색결과 183건 처리시간 0.032초

사슴의 혈액 및 혈액화학치에 관한 연구 (Blood and Serum Chemical Values on Deer Bred in Taegu Dalseung Park)

  • 이근우;장인호;송재찬;이동석
    • 한국임상수의학회지
    • /
    • 제13권2호
    • /
    • pp.127-129
    • /
    • 1996
  • The study was conducted to determine normal blood and serum chemical values on deer. Normal blood and serum chemical values were studied in 8 healthy deers bred at Dalseung Park in Taegu. The values were analyzed with a blood chemical analyzer and calculated by Chawen's statistical analysis. The blood values of RBC, WBC and PCV were $9.73{\pm}1.19{\times} 10^{6}/{\mu}l, 3.37{\pm}0.88{\times}10^{3}/{\mu}l, 47.25{\pm}4.65 % respectively. The serum chemical value were: GOT; 83.0{\pm}39.4 IU/L, GPT; 50.12{\pm}25.83 IU/L, BUN; 36.63{\pm}8.70 mg/dl. CPK ; 1,296{\pm}495 IU/L, ALP; 238{\pm}54 IU/L, glucose; 143{\pm}52 mg/dl, total protein; 6.95{\pm}0.61 g/dl, amylase ; 116.0{\pm}34.5 IU/L,$ respectively. These values will be clinically helpful to diagnose the disease of deer.

  • PDF

Algin Impregnated Vascular Graft I. In Vitro Investigation

  • Lee, Jin-Ho;Shin, Bung-Chul;Khang, Gil-Son;Lee, Hai-Bang
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.97-104
    • /
    • 1990
  • Microvel double velour graft impregnated with a biodegradable algin was studied as a new vascular graft. It is blood tight but still retains high porosity. Thls graft does not need to be preslotted with blood before implantation and has good tissue ingrowth and biological healing properties. The algin impregnated vascular graft was investigated by "in vitro" tests in this study. It was characterl zed by ESCA analysis, SEM observation, and measurements of water permeability, algin coating weight, mechanical properties and whole blood clotting time. The water permeability of the graft was reduced more than 99% and the whole blood clotting time was fast more than three times by the algin impregnation treatment. "In vivo" performance examinations of the algin impregnated graft are on progress.aft are on progress.

  • PDF

Ecological health assessments using multiple parameters of fish blood tissues to community along with water chemistry in urban streams

  • Kang, Han-il;Choi, Ji-Woong;Hwang, Seock-Yeon;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • 제38권3호
    • /
    • pp.307-318
    • /
    • 2015
  • The objectives of this study were to identify multi-level stressors from blood biomarkers to community-level bioindicators and diagnose the stream ecosystem health in polluted streams. Blood chemistry such as total protein ($T_{Pro}$), blood urea nitrogen ($B_{UN}$), total cholesterol ($T_{Cho}$) and $A_{lb}$umin ($A_{lb}$) were analyzed from sentinel fish tissues; the functions of kidney, gill and liver were significantly decreased in the impacted zone ($I_z$), compared to the control zone ($C_z$). Histopathological analysis showed that fish liver tissues were normal in the $C_z$. Fish liver tissues in the $I_z$, however, showed large cell necrosis and degeneration and also had moderate lobular inflammation and inflammatory cell infiltration of lymphocytic histocytes. Species biotic index (SBI) at species level and stream health assessment (SHA) at community level indicated that chemical impacts were evident in the $I_z$ (ecological health; poor - very poor), and this was matched with the blood tissue analysis and histopathological analysis. The impairments of the streams were supported by water chemistry analysis (nitrogen, phosphorus). Tolerance guild analysis and trophic guild analysis of fish were showed significant differences (P < 0.01) between $C_z$ and $I_z$. Overall, multiple parameter analysis from biomarker level (blood tissues) to bioindicator level (community health) showed significantly greater impacts in the $I_z$ than $C_z$. This approach may be effective as a monitoring tool in identifying the multilateral and forthcoming problems related to chemical pollution and habitat degradation of stream ecosystems.

Babesia gibsoni 감염견의 혈액화학치 변화 (Changes of Blood Chemical Values on Dogs Infected with Babesia gibsoni)

  • 이근우;장인호;송재찬;이성준
    • 한국임상수의학회지
    • /
    • 제15권1호
    • /
    • pp.219-221
    • /
    • 1998
  • This report was conducted to determine the changes of blood and serum chemical values on dogs infected with Babesia gibsoni. Blood and serum were obtained and analyzed with a blood chemical analyzer and calculated by Chauvent's statistical analysis. The mean values and SD were as follows, $AST 33{\pm} 23 IU/L, ALT 22{\pm}15 IU/L, BUN 18$\pm $8 mg/dl, creatinine 1.6{\pm}0.8 mg/dl, CPK 564{\pm}214 IU/L, LDH 208{\pm} 78 IU/L, ALP 52{\pm} 8 IU/L, glucose 89{\pm}38 mg/dl, RBC 3.04{\pm}0.77{\times}10^{6}/{\mu}l, hemoglobin 6.1{\pm} 1.3 g/dl, PCV 18.0{\pm }4.3%, $respectively.

  • PDF

MALDI-MS-Based Quantitative Analysis of Bioactive Forms of Vitamin D in Biological Samples

  • Ahn, Da-Hee;Kim, Hee-jin;Kim, Seong-Min;Jo, Sung-Hyun;Jeong, Jae-Hyun;Kim, Yun-Gon
    • Korean Chemical Engineering Research
    • /
    • 제58권1호
    • /
    • pp.106-112
    • /
    • 2020
  • Analyzing vitamin D levels is important for monitoring health conditions because vitamin D deficiency is associated with various diseases such as rickets, osteomalacia, cardiovascular disorders and some cancers. However, vitamin D concentration in the blood is very low with optimal level of 75 nmol/L, making quantitative analysis difficult. The objective of this study was to develop a highly sensitive analysis method for vitamin D using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS). 25-hydroxyvitamin D (25(OH)D), which has been used as an indicator of vitamin D metabolites in human biofluids was chemically derivatized using a secosteroid signal enhancing tag (SecoSET) with powerful dienophile and permanent positive charge. The SecoSET-derivatized 25(OH)D provided good linearity (R2 > 0.99) and sensitivity (limit of quantitation: 11.3 fmol). Chemical derivatization of deuterated 25-hydroxyvitamin D3 (d6-25(OH)D3) with SecoSET enabled absolute quantitative analysis using MALDI-MS. The highly sensitive method could be successfully applied into monitoring of quantitative changes of bioactive vitamin D metabolites after treatment with ketoconazole to inhibit 1α-hydroxylase reaction related to vitamin D metabolism in human breast cancer cells. Taken together, we developed a MALDI-MS-based platform that could quantitatively analyze vitamin D metabolites from cell products, blood and other biofluids. This platform may be applied to monitor various diseases associated with vitamin D deficiency such as rickets, osteomalacia and breast cancer.

Total Cholesterol and Alkaline Phosphatase are Increased in D/D Type of Angiotensin Converting Enzyme

  • Kim, Sung-Su
    • 대한의생명과학회지
    • /
    • 제18권4호
    • /
    • pp.406-412
    • /
    • 2012
  • The polymorphism (insertion, I or deletion, D) of angiotensin converting enzyme (ACE) gene is designated as the presence of a 287 bp Alu repeat. The D/D homozygote carrier is associated with high ACE activity, and this high activity has been implicated with hypertension, coronary artery disease, or diabetic nephropathy. We studied the clinical candidate marker in ACE gene polymorphism using chemical and hematological analysis. The subjects are divided into normotensive and hypertensive groups and ACE genotype in the group was confirmed by PCR method. Chemical analysis was preceded with Hitachi7060, and hematological analysis was performed using Mythic 22. In 116 targeted people, 17 (38.64%) of 44 I/I genotype group are hypertension, 15 (34.09%) in 44 with D/I, but, D/D type in the 28 cases is 15 patients (53.57%) in hypertension. In hypertension group, biochemical analysis (triglyceride, and alkaline phosphatase) and hematological analysis (white blood cell, platelet) are showed high value in D/D genotype of ACE gene. The relationship between hypertension and ACE genotype is the same results as previously reported and we thought that the high laboratory value of white blood cell, platelet, triglycerides, and alkaline phosphatase are also indicator of hypertension in D/D type of ACE.

한우에 발생한 전형적인 지방종증의 1례 (A Typical Case of Lipomatosis Occurred in a Korean Native Cow)

  • 송근호;노용우;김덕환;조규완;황수현;서지민;홍민성
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.478-481
    • /
    • 2001
  • A Patient (Korean native cow, 4 years old, 300 kg, female), with chief complaint of anorexia for long period was admitted to the Chungnam national University Veterinary Medical Teaching Hospital. At necropsy findings, hard masses of necrotic fat were located in the omentum, rectum, kidney, colon, heart and thoracic cavity, respectively. The yellowish changes also were observed in liver, spleen and lung, respectively. In histopathological findings, fatty accumulation was observed by microscopic observation in each organ of fatty masses. Hamatological analysis revealed the low levels of Hb, PCV and neutrophil. Blood chemical analysis indicated the high concentration of Cholestelol and Triglyceride. That patient was diagnosed as typical case of lipomatosis by clinical, blood, blood chemical and pathological examinations.

  • PDF

CFD 해석을 이용한 Balloon형 인공심폐기 설계를 위한 구조적 해석 (Structural Analysis for Constructing a Balloon Type Extracoporeal Membrane Oxygenator using CFD Analysis)

  • 박영란;심정연;김기범;김상진;강형섭;김진상;김민호;홍철운;김성종
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.238-243
    • /
    • 2011
  • 본 연구는 기존의 인공심폐기의 단점을 보완하기 위하여 혈액펌프를 사용하지 않고 혈류의 흐름을 유도할 수 있는 기구(balloon)형 인공심폐기 설계를 위한 구조적 해석을 시도하였다. 가상의 모형 인공심폐기 내에서의 혈류의 흐름패턴을 분석하기 위하여 CFD 모델링 방법을 사용하였다. 이 시스템의 작동원리는 막 산화기 주위를 기구를 사용하여 압력하중을 인가하여 주기적으로 수축.이완되도록 하였으며, 시간에 따라 변화하는 시간 함수 값은 sine 반주기와 sine 주기를 계산하여 적용하였다. 이와 같은 방법으로 기구형 인공심폐기를 설계할 경우 한 방향에 대한 혈류의 움직임을 유도할 수 있다는 가정 하에 구조적 해석을 하였다. 실험결과 CFD 시뮬레이션을 통하여 인공심폐기의 입구와 출구에 서의 혈류의 속도와 압력을 측정하여 분석한 결과 한 방향에 대한 혈류의 유동이 발생하는 것을 확인하였다. 이와 같은 CFD 시뮬레이션은 혈류의 흐름특성을 미리 예측할 수 있어 인공심폐기 설계에 있어서 최적화된 디자인을 제공할 수 있을 것이라 판단된다.

음주운전자 275명 혈액 중 마약류 및 남용약물의 분석 (Distribution of Abused Drugs in 275 Alcohol-positive Blood Samples of Korean Driver)

  • 최혜영;이주선;최상길;김은미;김재균;김영운;임미애;정희선
    • 약학회지
    • /
    • 제52권2호
    • /
    • pp.137-146
    • /
    • 2008
  • Even though driving under the influence of drug (DUID) is a worldwide problem, we, Korea has no regulation system yet except for alcohol, and there are little cases reported related to DUID. In order to investigate the type of abused drugs for drivers in Korea, we tried to analyze controlled and non-controlled drugs in alcohol-positive blood samples. 275 whole bloods, which were positive for alcohol on the roadside test, were collected from the police for two months ($Nov.{\sim}Dec.$ 2006). The analytical strategy was constituted of three steps: First, alcohol in blood samples were confirmed and quantified by gas chromatography. Second, controlled drugs were screened by $Evidence_{investigator}\;^{TM}$ (Randox, U.K.) as preliminary test. It was based on immunoassay by biochip array analyzer. Nine groups of drug abuse were screened: amphetamines, methamphetamines, cannabis, cocaine, opiates, barbiturates, methadone, benzodiazepines I (oxazepam) & II (lorazepam). Finally, confirmation of these drugs was performed by GC-MS. Blood samples were extracted by solid-phase extraction by $RapidTrace^{TM}$ (Zymark, U.S.A.). After trimethylsilyl (TMS) derivatization, eluates were analyzed to GC-MS. Total 49 drugs were investigated in this study including controlled drugs, antidepressants, 1st generation antihistamines, dextromethorphan, nalbuphine, ketamine, etc. For rapid detection, we developed the automated identification system. It was made up a new software, "DrugMan", modified Chemstation data analysis menu and newly developed macro modules. A series of peak selection, identification and reporting of the results were performed automatically by this system. Concentrations of alcohol in 275 blood samples were ranged from 0.011 to 0.249% (average, 0.119%). Among 149 blood samples, just six samples (4.0%) were showed positive results to the immunoassay: one methamphetamine and five benzodiazepines group I. By GC-MS confirmation, only benzodiazepines were detected and methamphetamine was not detected from immunoassay positive blood sample. Besides these drugs, 5 chlorpheniramines, dextromethorphan, diazepam, doxylamine, ibuprofen, lidocaine and topiramate were also detected in whole bloods by GC-MS. Conclusively, the frequency of drug abuse for Korean drivers was relatively low. There was none case which illegal drug was detected. However these results were limited to alcohol positive blood samples, so it is necessary to analyze more samples including alcohol negative blood.