• Title/Summary/Keyword: bipolar

Search Result 1,561, Processing Time 0.027 seconds

Differential LC VCO with Enhanced Tank Structure and LC Filtering Techniques in InGaP/GaAs HBT Technology (InGaP/GaAs HBT 공정을 이용하여 향상된 탱크 구조와 LC 필터링 기술을 적용한 차동 LC 전압 제어 발진기 설계)

  • Lee, Sang-Yeol;Kim, Nam-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.177-182
    • /
    • 2007
  • This paper presents the InGaP/GaAs HBT differential LC VCO with low phase noise performance for adaptive feedback interference cancellation system(AF-lCS). The VCO is verified with enhanced tank structure including filtering technique. The output tuning range for proposed VCO using asymmetric inductor and symmetric capacitors withlow pass filtering technique is 207 MHz. The output powers are -6.68 including balun and cable loss. The phase noise of this VCO at 10 kHz, 100 kHz and 1 MHz are -102.02 dBc/Hz, -112.04 dBc/Hz and -130.40 dBc/Hz. The VCO is designed within total size of $0.9{\times}0.9mm^2$.

Success Rate of Tubal Sterilization Reversal (정부지원 난관복원수술의 성공율에 관한 연구)

  • Bai, Byoung-Choo;Park, Chan-Moo;Kwak, Hyun-Mo;Whang, Young-Whan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.20 no.1
    • /
    • pp.79-85
    • /
    • 1993
  • Five hundred and fory-four women were provided government funded sterilization reversal services with technique of microsurgery at 15 reversal institutions designated by the Korean Association for Voluntary Sterilization since the inception of Female Reversal Program in 1981. A large majority of reasons for requesting reversal surgery was a loss of children, comprising 87.3%, and the mean interval between sterilization and reversal was 33.6 months. Two hundred and ninty-one of 418 women who were post-operatively followed up with the length of 11 months to 11 years, have experienced term dilivery or ,intra-uterine pregnancy, represented 69.6%. Eight cases have experienced ectopic pregnancy and 9 cases spontaneous abortion. The largest number of reversal clients were sterilized by the laparoscopic unipolar coagulation technique and the next largest group was sterilized by the laparoscopic banding technique, representing 59.8% and 28.9% respectively. The highest pregnancy rate, 80.9%, was shown in clients who had undergone laparoscopic banding technique while the lowest, 61.8%, was the group of laparoscopic bipolar coagulation. The most common site of the anastomosis was isthmic-ampullary portion and the next was isthmic-isthmic portion. The highest success rate, 77.8 %, was marked in the isthmic-isthmic anastomosis and the lowest was in the ampullary-ampullary anastomosis, representing 50.0%. A more than 60% of the clients became pregnant within 6 months of their reversal surgery, with the shortest interval being 1 month, the longest 39 months, and the mean 7.6 months. A large majority of the successful cases were pregnancy within 1 year of their reversal surgery, representing 82.1 %. The higher rate of pregnancy, 73.5%, was in the clients undergone reversal surgery within 36 months of their sterilization and the lower pregnancy rate, 64.1 %, was in the clients undergone reversal surgery longer than 37 months of their sterilization.

  • PDF

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

Delayed Continuous Venovenous Hemodiafiltration in Chronic Lithium Intoxication (만성 리튬 중독환자의 지연성 정정맥 혈액 투석여과 사례)

  • Kim, Tae Su;Cha, Yong Sung;Kim, Hyun;Kim, Oh Hyun;Cha, Kyoung Chul;Lee, Kang Hyun;Hwang, Sung Oh
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.1
    • /
    • pp.28-30
    • /
    • 2013
  • A 66-year-old male with chronic alcoholism presented with tremor, gait disturbance, memory impairment, insomnia, decreased appetite, and confusion. The patient had been taking lithium daily for treatment of bipolar disorder. Brain CT showed no specific abnormality, and serum lithium and ammonia levels were 3.63 mEq/L (therapeutic range, 0.6~1.2 mEq/L) and $85{\mu}g/dL$ (reference range: $19{\sim}54{\mu}g/dL$), respectively. Therefore, the initial differential diagnosis included chronic lithium intoxication, hepatic encephalopathy, Wernicke encephalopathy, or alcohol withdrawal syndrome. Even with the provision of adequate hydration, the patient's neurologic status did not show improvement, so that lactulose enema, thiamine replacement, and continuous venovenous hemodiafiltration (CVVHDF) were started on the third admission day. By the fifth admission day he had made a rapid neurologic recovery, and was discharged on the 20th admission day. Therefore, CVVHDF might be a treatment for patients with chronic lithium intoxication, because, even if serum lithium concentration is normal, lithium concentration in the brain may be different from that of the serum.

  • PDF

Rate-Responsive Permanent Pacemaker Implantation in a Pekingese Dog with a Sick Sinus Syndrome (동방결절 기능 부전군을 가진 페키니즈 종의 개에 대한 심장 박동수 반응형 영구 심장 박동기의 장착)

  • Han, Dong-Hyun;Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.569-572
    • /
    • 2010
  • A 4-year-old neutered female Pekingese dog (weighing 3.6 kg) was referred with the primary complaint of exercise intolerance with occasional syncope. Physical examination revealed irregularly irregular heart rhythm with persistent pulse deficits. The 12-lead surface ECG showed a marked sinus arrest with occasional junctional escape beats, indicating a sick sinus syndrome. Permanent transvenous cardiac pacing with a rate-responsive bipolar implantable pacemaker (VVIR type) was performed in the right ventricle. After pacemaker implantation, the clinical signs were remarkably improved. No further syncopal episodes have yet been occurred after implantation.

The effects of electroacupuncture on stomach and cecum motility in horses (전침자극이 말의 위와 맹장의 운동성에 미치는 영향)

  • Kim, Byung-sun;Choi, Hee-in
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.183-199
    • /
    • 1998
  • The effects of electroacupuncture(EA) on gastrointestinal motility were investigated in 6 horses. Three acupuncture points ; Guan Yuan Shu(BL-26), Wei Shu(BL-21) and Da Chang Shu(BL-25) were stimulated for 20 minutes by EA at separate occasions under varying condition ; 2V-1Hz, 2V-5Hz, 2V-30Hz, 4V-1Hz, 4V-5Hz and 4V-30Hz. Myoelectric activity of stomach and cecum was monitored to investigate the gastrointestinal motility. Electromyogram(EMG) recordings were carried out before, 0, 20 minutes after and 40 minutes after the EA stimulation. EMG bipolar electrode was surgically implanted in seromuscular layer of greater curvature in the stomach and between medial band and ventral band in the cecum. The EA stimulation and monitoring were not commenced until 15 days after electrode implantation. The EA stimulation of Wei Shu influenced on stomach motility and that of Da Chang Shu on, cecum motility. However, the EA stimulation of Guan Yuan Shu influenced on both the stomach and the cecum motility. The myoelectrical spike burst amplitude of the stomach and the cecum was significantly(p<0.05) increased by 2V-1Hz stimulation, but the myoelectrical spike burst frequence of the stomach and the cecum was significantly decreased by 2V-30Hz or 4V-30Hz stimulation. The myoelectrical spike burst duration of the stomach and the cecum was significantly lengthened by 4V-30Hz and 2V or 4V-30Hz stimulation, respectively.

  • PDF

Histopathological observations and virus detection by in situ hybridization in wild rats intranasally infected with Aujeszky's disease virus isolated in Korea (국내분리 오제스키병 바이러스로 비강접종한 야생집쥐(Rattus norvegicus)의 병리학적 소견 및 in situ hybridization에 의한 바이러스 동정)

  • Song, Geun-seok;Moon, Oun-kyong;Jeong, Chang-geun;Kim, Soon-bok
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.531-537
    • /
    • 1999
  • The present study was carried out to investigate the pathogenicity and pathogenesis of wild rats(Rattus norvegicus), trapped in nature, intranasally infected with Aujeszky's disease virus(ADV/NYJ-1-87) by histopathology, immunohistochemistry and in situ hybridization(ISH). Fifteen rats inoculated intranasally were roughened haircoat, anorexia, listlessness, and depression second day after inoculation, and three rats died in 66-72 hours. Eight rats showed severe pruritus at the face that was accompanied by frequent face-washing movements of the forelegs, and then became violent and spasmodic for an hour or until they died. Four rats slowly recovered after showing mild clinical signs of the disease. Microscopic lesions in infected rats were characterized by meningitis, perivascular round cell infiltration, focal gliosis, and neuronal degeneration and necrosis. And intranuclear inclusion bodies were frequently detected in the cerebral cortex and medulla. Positive reaction to ADV by immunohistochemistry and ISH were detected in the following areas : trigermimal ganglion, brain, tonsil, nasal mucosa, spleen, lung and liver. The result has suggested that ADV intranasally infected in wild rats is followed by replication in epithelial calls of nasal mucosa and tonsil, then invade local lymph nodes by way of the lymphatics. It is also believed that the virus invades bipolar olfactory cells and trigerminal ganglion; and then spread into central nervous system.

  • PDF

WN 박막을 이용한 저항 변화 메모리 연구

  • Hong, Seok-Man;Kim, Hui-Dong;An, Ho-Myeong;Kim, Tae-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.403-404
    • /
    • 2013
  • 최근 scaling down의 한계에 부딪힌 DRAM과 Flash Memory를 대체하기 위한 차세대 메모리(Next Generation Memory)에 대한 연구가 활발히 진행되고 있다. ITRS (international technology roadmap for semiconductors)에 따르면 PRAM (phase change RAM), RRAM (resistive RAM), STT-MRAM (spin transfer torque magnetic RAM) 등이 차세대 메모리로써 부상하고 있다. 그 중 RRAM은 간단한 구조로 인한 고집적화, 빠른 program/erase 속도 (100~10 ns), 낮은 동작 전압 등의 장점을 갖고 있어 다른 차세대 메모리 중에서도 높은 평가를 받고 있다 [1]. 현재 RRAM은 주로 금속-산화물계(Metal-Oxide) 저항 변화 물질을 기반으로 연구가 활발하게 진행되고 있다. 하지만 근본적으로 공정 과정에서 산소에 의한 오염으로 인해 수율이 낮은 문제를 갖고 있으며, Endurance 및 Retention 등의 신뢰성이 떨어지는 단점이 있다. 따라서, 본 연구진은 산소 오염에 의한 신뢰성 문제를 근본적으로 해결할 수 있는 다양한 금속-질화물(Metal-Nitride) 기반의 저항 변화 물질을 제안해 연구를 진행하고 있으며, 우수한 열적 안정성($>450^{\circ}C$, 높은 종횡비, Cu 확산 방지 역할, 높은 공정 호환성 [2] 등의 장점을 가진 WN 박막을 저항 변화 물질로 사용하여 저항 변화 메모리를 구현하기 위한 연구를 진행하였다. WN 박막은 RF magnetron sputtering 방법을 사용하여 Ar/$N_2$ 가스를 20/30 sccm, 동작 압력 20 mTorr 조건에서 120 nm 의 두께로 증착하였고, E-beam Evaporation 방법을 통하여 Ti 상부 전극을 100 nm 증착하였다. I-V 실험결과, WN 기반의 RRAM은 양전압에서 SET 동작이 일어나며, 음전압에서 RESET 동작을 하는 bipolar 스위칭 특성을 보였으며, 읽기 전압 0.1 V에서 ~1 order의 저항비를 확보하였다. 신뢰성 분석 결과, $10^3$번의 Endurance 특성 및 $10^5$초의 긴 Retention time을 확보할 수 있었다. 또한, 고저항 상태에서는 Space-charge-limited Conduction, 저저항 상태에서는 Ohmic Conduction의 전도 특성을 보임에 따라 저항 변화 메카니즘이 filamentary conduction model로 확인되었다 [3]. 본 연구에서 개발한 WN 기반의 RRAM은 우수한 저항 변화 특성과 함께 높은 재료적 안정성, 그리고 기존 반도체 공정 호환성이 매우 높은 강점을 갖고 있어 핵심적인 차세대 메모리가 될 것으로 기대된다.

  • PDF

탄소나노튜브 에미터 기반 Flat Light Lamp 제작 시 금속전극 선폭과 간격 변화에 따른 전계방출 특성평가

  • Lee, Han-Seong;Im, Byeong-Jik;Ha, In-Ho;O, Se-Uk;Lee, Cheol-Seung;Lee, Gyeong-Il;Jo, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.520-520
    • /
    • 2013
  • Lateral 구조를 갖는 탄소나노튜브 에미터 캐소드의 금속전극 선폭과 간격은 탄소나노튜브 에미터 밀도와 게이트에 인가되는 전계의 크기에 밀접한 관계가 있어 전계방출특성에 큰 영향을 나타내므로 조속한 상업화를 위해서는 최적화 연구가 요구된다. 따라서 본 연구에서는 금속전극의 선폭과 간격을 110/30, 80/30, 40/30과 120/20, 90/20, 20/20 ${\mu}m$로 각각 변화시켜 4.6인치 탄소나노튜브 에미터 기반 flat light lamp 개발연구를 진행하였다. 이때 사용한 금속전극은 2 mm 두께를 갖는 4.6인치 소다라임 글라스 위에 패턴 된 PR에 Ag를 sputtering하여 증착 후 PR을 lift-off하여 형성하였다. 이와 같이 형성된 금속전극은 ~1 ${\mu}m$와 12 nm의 두께와 표면단차를 각각 가지고 있었다. 형성된 금속전극 위에 유전체와 탄소나노튜브 에미터를 각각의 페이스트를 사용하여 스크린 인쇄와 소성과정을 통해 형성하였다. 이때 레이저 빔을 전극사이의 빈 공간에 조사하여 탄소나노튜브 에미터를 금속전극 위에 정밀하게 정렬하였으며 잔존하는 유기물과 유기용매를 없애기 위해 대기압 공기분위기의 $410^{\circ}C$에서 10분간 소성과정을 거친 후 접착테이프를 사용하여 잔탄 속에 있는 탄소나노튜브 에미터를 물리적 힘으로 수직하게 노출시켜 캐소드를 준비하였다. 애노드는 전계에 의해 방출된 전자의 측정과 전계방출 이미지를 얻기 위해서 P22 형광체와 Al박막이 증착된 2 mm 두께의 소다라임 글라스를 사용하였다. 캐소드와 애노드 사이의 간격은 6~10 mm로 유지하였고, 진공챔버의 기본 압력을 $5{\times}10^{-6}$ Torr 이하로 유지하였다. 캐소드와 게이트 전극에 1, 4 kHz와 3% duty를 갖는 bipolar 형태의 DC 사각펄스파를, 애노드에 ~18 kV의 DC 고전압을 각각 인가하여 평가하였으며 추후, 이렇게 제작된 다양한 선폭과 간격을 갖는 탄소나노튜브 에미터 기반 flat light lamp의 전계방출특성과 효율에 대한 비교 연구를 진행할 계획이다.

  • PDF

THE INHIBITORY EFFECT OF LOW FREQUENCY ELECTRICAL STIMULATION ON THE DENTAL AND GINGIVAL PAIN OF DOG (저빈도 전기자극이 개의 치아 및 치은에 대한 동통억제효과)

  • Kweon, Hoon;Song, Hyung-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.525-536
    • /
    • 1996
  • The purpose of this study was to investigate the effect of electrical anesthesia induced by non-acupuncture point stimulation on inhibition of amplitude of digastric EMG evoked by noxious electrical stimuli in teeth and gingiva. Experiments were performed with dogs anesthetized with intraperitoneal pentobarbital sodium in an initial dose of 30mg/kg. Maintenance doses of 4.0ml/hour were given through a cannula in the femoral vein using a constant infusion pump. Anterior belly of digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for E.M.G. recording. Bipolar electrodes were inserted into the labial and lingual surface of upper canine and the labial area of upper gingiva. Noxious stimuli were delivered to the tooth and gingiva through those electrodes by electric stimulator. Non-acupuncture point stimulation of 2Hz was delivered bilaterally to the femoral area. Amplitudes of digastric E.M.G. were measured from the oscilloscope and the monitor connected to amplifier at different intensities of electronic anesthesia of 1 volt, 4 volt and 10 volt. The inhibited rate of the amplitudes of digastric E.M.G. were analysed statistically with paired t-test. The following results were obtained : 1. Non-acupuncture point stimulation with intensities of 1 volt, 4 volt and 10 volt showed the inhibitory effect on pain of 15%, 25% and 16% in teeth and 15%, 18% and 12% in gingiva respectively 2. In tooth, statistical significance was observed between control and each group. In gingiva, there was statistical significance between control and group 1, 2 except group 3 From these results, low frequency electrical stimulation of non-acupuncture point resulted in reducing of dental and gingival pain, it could be used as adjunct to other pain control methods.

  • PDF