• Title/Summary/Keyword: bionics

Search Result 128, Processing Time 0.036 seconds

Enhancement of Mass Transfer Using Piezoelectric Material in Fluid Flow System

  • Kim, Gi-Beum;Chong, Woo-Suk;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun;Jheong, Gyeong-Rak
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.165-170
    • /
    • 2004
  • The purpose of this work was to assess and quantify the beneficial effects of long-term gas exchange, at varying frequencies, for the development of a vibrating intravascular lung assistance device (VIVLAD), for patients suffering from acute respiratory distress syndrome (ARDS). The experimental design and procedure have been applied to the construction of a new device for assessing the effectiveness of membrane vibrations. An analytical solution has been developed for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers, with the intention of gaining insight into how wall vibrations might enhance the performance of the VIVLAD. As a result, the maximum oxygen transfer rate was reached at the maximum amplitude and through the transfer of vibrations to the hollow fiber membranes. The device was excited by a frequency band of 7Hz at various water flow rates, as this frequency was the 2nd mode resonance frequency of the flexible beam. 675 hollow fiber membranes were also bundled, within the blood flow, into the device.

  • PDF

Analysis of Muscular Activity for the Swing Motion Using Soft Golf (소프트 골프를 이용한 스웡 시 근육 사용도 분석)

  • Kim K.;Kim Y.Y.;No B.H.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.522-525
    • /
    • 2005
  • The purpose of this study was to analyze the pattern of muscle usage during swing motion with a soft golf club in comparison with that with a normal golf club. The subjects were normal healthy young adults. The subjects performed swing motion using normal and soft golf clubs in turn. Then, we compared and analyzed the muscular activities for the two cases. The muscular activities of the subject was measured using MP100(BIOPAC Systems, Inc.). For the analysis of muscular activities, we measured EMG(Electromyography) of the subjects during swing motion. The muscles analyzed were deltoid, latissimus dorsi, external oblique, and rectus abdominis of the upper limbs and rectus femoris, biceps femoris, gastrocnemius, and soleus of the lower limbs. The result of the experiment showed that the pattern of muscle usage with soft golf club was similar to that with a normal golf club but the muscular activities with the soft golf was smaller than that with the normal golf club.

  • PDF

Development of System of the Visuo-Auditory Stimulation and Human Responses Measurement (시청각 자극 및 인체 반응 계측 시스템 개발)

  • Yu M.;Jung S.Y.;Piao Y.J.;Lee S.M.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.535-538
    • /
    • 2005
  • The purpose of this work is to study a process organization on space cognition by visio-auditory stimulation. We develop the system of visuo-auditory stimulation and Humans responses measurement to observe the relationship between the sensory and the motor system fur the localization of visual and auditory target direction in the space. The experiments is performed in a soundproof chamber, 2163 red, green and yellow LED(Luminescent Diode, Brightness: $20cd/m^2$ 1 degree apart each other)arrayed in front of half-circle panel were used and 57 Speaker(5 degree apart each other) arrayed in the hidden of half-circle panel. Physiological parameters such as EOG (Electro-Oculography), head movement and their synergic control are measured by BIOPAC system and Optotrak Certus. This result shows that the response latency time of the perception motion in the center is laster than the periphery of panel. These results can be used in the study of characterizing the spatial cognition.

  • PDF

A Study on the Effect of Vibration Input toward the Sense of Equilibrium (진동이 평형감각에 미치는 영향에 관한 연구)

  • Jeong S.H.;Piao Y.J.;Lee S.M.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.539-542
    • /
    • 2005
  • In this study, we investigated the influence of vibrational stimulation on postural control. To study the effect, the sway of the center of pressure was observed fur two different visual conditions and for three different patterns of vibrational stimulation on plantar area. The two visual conditions were normal condition with visual feedback and blind condition with both eyes closed. The three vibrational stimulations were white noise, constant vibration, and vibration with amplitude modulations (sine curve modulation). The experimental results showed that the sway of the center of pressure distinctively reduced with white noise vibrational stimulation. This result showed that it's possible to use vibrational stimulation for improving the ability of postural control.

  • PDF

Testing of Load Capacity of a Foil Thrust Bearing

  • Kim, Choong Hyun;Park, Jisu
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.300-306
    • /
    • 2018
  • In this study, the performance of foil thrust bearings was investigated by performing bearing take-off and load capacity tests, using an in-house designed and manufactured vertical bearing test rig. The mean take-off rotational speed and maximum load capacity of the bearing specimen were ~18,000 rpm and ~80 kPa, respectively. The vertical bearing test rig was observed to yield higher coefficients of friction and frictional torques than a horizontal bearing test rig under identical test conditions. This was a result of its structural characteristics, in that the bearing specimen is placed atop the thrust runner, which keeps it from being separated from the runner after the bearing take-off. In addition, bearing take-off was observed at a higher runner rotational speed as this structure keeps air from flowing between the top foil and runner surfaces, which requires a higher runner speed. The parallel alignment between the bearing specimen and runner surfaces can be maintained within a certain range more easily in a vertical test rig than in a horizontal test rig. Because of these advantages, Korean Industrial Standard, KS B 2060, recommends a vertical bearing test rig as the standard test device for foil thrust bearings.

The Activities of Human Autonomic Nervous System by Foot Bathing (족욕이 인체 자율 신경기능에 미치는 영향에 관한 연구)

  • Kim H.J.;Yu M.;Choi K.J.;Yang Y.S.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1929-1932
    • /
    • 2005
  • We investigated the activities of autonomic nervous system during foot bathing. The effect of foot bathing was evaluated for four subjects by observing the characteristic of heart rate variability and bodily temperatures. The foot bathing was done with a commercial foot spa (Duches Co.) utilizing the four functional modes of the spa for two different temperatures of $35^{\circ}C\;and\;40^{\circ}C$. The four functional modes were clam, vibration, air bubbles, and both vibration and air bubbles. The experimental results showed that the temperature of foot and that of face right after foot bathing were not that different from each other. But, for heart rate variability, the activation of parasympathetic nerve showed distinctive increase at $40^{\circ}C$ of water temperature. In the analysis of heart rate variability for different functional modes, the change was not distinctive for different modes at $35^{\circ}$ of water temperature. However, at $40^{\circ}C$, the activation of sympathetic nerve showed distinctive increases with the increase in the complexity of functional modes.

  • PDF

Validation on the Application of Bluetooth-based Inertial Measurement Unit for Wireless Gait Analysis (무선 보행 분석을 위한 블루투스 기반 관성 측정 장치의 활용 타당성 분석)

  • Hwang, Soree;Sung, Joohwan;Park, Heesu;Han, Sungmin;Yoon, Inchan
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.121-127
    • /
    • 2020
  • The purpose of this paper is to review the validation on the application of low frequency IMU(Inertial Measurement Unit) sensors by replacing high frequency motion analysis systems. Using an infrared-based 3D motion analysis system and IMU sensors (22 Hz) simultaneously, the gait cycle and knee flexion angle were measured. And the accuracy of each gait parameter was compared according to the statistical analysis method. The Bland-Altman plot analysis method was used to verify whether proper accuracy can be obtained when extracting gait parameters with low frequency sensors. As a result of the study, the use of the new gait assessment system was able to identify adequate accuracy in the measurement of cadence and stance phase. In addition, if the number of gait cycles is increased and the results of body anthropometric measurements are reflected in the gait analysis algorithm, is expected to improve accuracy in step length, walking speed, and range of motion measurements. The suggested gait assessment system is expected to make gait analysis more convenient. Furthermore, it will provide patients more accurate assessment and customized rehabilitation program through the quantitative data driven results.

Analysis on the Effect of a Training System for Improving Equilibrium Sense Using an Unstable Platform

  • Piao, Yong-Jun;Yu, Mi;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2455-2458
    • /
    • 2005
  • In this paper, we analyzed the effect of a training system for improving equilibrium sense. This training system consists of an unstable platform, a force plate, a computer, and training programs. Using the system with training programs, we performed various experiments to train the equilibrium sense of fifteen subjects. To evaluate the effect of the training system, we measured the time a subject maintains a focus, the moving time to the target, and the absolute deviation of the trace. We analyzed these parameters obtained before and after the training using paired-samples T-test. The results showed that the subjects experienced a distinctive enhancement of their equilibrium senses through the training using our system.

  • PDF

Analysis of the Muscular Force on the Swing Using Soft Golf Club (소프트 골프 클럽을 이용한 스윙 시 근력 분석)

  • Kim K.;Choi H.Y.;Eun H.I.;Lee S.C.;No B.H.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.903-906
    • /
    • 2005
  • The purpose of this study was to analyze the muscular force of swing using the soft golf club in comparison with the muscular force of swing using normal golf club. The subject was normal adult (twenties) and performed swing motion using normal and soft golf club. And then we compared muscular power soft golf club with normal golf club of the subject. The muscular power of the subject was measured by MP 100(BIOPAC Systems, Inc.). For the analysis of muscular power of swing using soft golf club, we measured EMG(Electromyography) of the subject. The position of muscle was deltoid, latissimus dorsi, external oblique and rectus abdominis of the upper limbs and rectus femoris, biceps femoris, gastrocnemius and soleus of the lower limbs. The result of experiment, muscle pattern of swing using soft golf club was similar to pattern of swing using normal golf club and muscular power of subjects using the soft golf was smaller than normal golf.

  • PDF