• Title/Summary/Keyword: biomedical

Search Result 13,438, Processing Time 0.045 seconds

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

The Design of Feature Selection Classifier based on Physiological Signal for Emotion Detection (감성판별을 위한 생체신호기반 특징선택 분류기 설계)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.206-216
    • /
    • 2013
  • The emotion plays a critical role in human's daily life including learning, action, decision and communication. In this paper, emotion discrimination classifier is designed to reduce system complexity through reduced selection of dominant features from biosignals. The photoplethysmography(PPG), skin temperature, skin conductance, fontal and parietal electroencephalography(EEG) signals were measured during 4 types of movie watching associated with the induction of neutral, sad, fear joy emotions. The genetic algorithm with support vector machine(SVM) based fitness function was designed to determine dominant features among 24 parameters extracted from measured biosignals. It shows maximum classification accuracy of 96.4%, which is 17% higher than that of SVM alone. The minimum error features selected are the mean and NN50 of heart rate variability from PPG signal, the mean of PPG induced pulse transit time, the mean of skin resistance, and ${\delta}$ and ${\beta}$ frequency band powers of parietal EEG. The combination of parietal EEG, PPG, and skin resistance is recommendable in high accuracy instrumentation, while the combinational use of PPG and skin conductance(79% accuracy) is affordable in simplified instrumentation.

Effects of Mental Practice on Balance Ability and Fall Efficacy in Dwelling Elderly Population: Single Subject Design (상상연습이 노인의 균형 능력과 낙상효능감에 미치는 영향 : 단일대상연구)

  • Chung, Jun-Chul;Jung, Hae-Yoon;Lee, Chang-Dae;Yoo, Eun-Young
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.5 no.2
    • /
    • pp.31-42
    • /
    • 2015
  • Objective : The aim of this study is to prove the effects of mental practice in balance ability of elderly population, and to investigate the possibility of application as an effective intervention method for fall prevention. Methods : This study provided mental practice to 3 subjects over 65 years old who have experienced fall, but do not have cognitive dysfunctions and independent in gait without any use of assistive devices from July to October, 2013. Within the individual case study, 4 sessions of initial baseline process (A), 5 sessions of mental practice (B), 4 sessions of re-initial baseline process (A') were proceeded using ABA design. Independent variable used mental practice for enhancing balance ability and fall efficacy in elderly population, and dependent variable were Berg Balance Scale (BBS) to find out the change in overall balance ability, Fall Efficacy Scale (FES) to see the change in fall efficacy, One-Leg Standing test(OLS), and Timed Up and Go Test (TUG) to determine the changes in both static and dynamic balance. Analysis of the results were provided via mean value and graph. Results : After the application of mental practice method, all of the subjects have shown increase in fall efficacy baseline values, and in addition, overall balance ability and both static and dynamic balances either increased or maintained. Conclusion : This study demonstrated that mental practice has positive effects on fall efficacy improvement and maintenance in elderly, thereby suggesting mental practice for fall prevention in elderly populations.

A Study on Property with Ratio of Water Mixture in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막 방수재의 물 혼합비에 따른 물성변화연구)

  • Park, Jin-Sang;Park, Wan-Goo;Kim, Dong-Bum;Lee, Min-Kyu;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.348-354
    • /
    • 2015
  • Urethane waterproofing materials which currently being used most commonly in the Korean domestic market have high applicability and construct layers without forming any joints, but under the influence of low temperature and low humidity, as well as the thickness of the applied layer, the curing time of this material may become extended in construction sites. To resolve these issues, a proposed method of using water-hardening type of polyurethane waterproofing materials are being developed. However, there currently lacks any standards or evaluation methods on determining an optimal mixture ratio of water for the water-hardening polyurethane waterproofing materials. Therefore, workers and construction workers are relying on their hands-on-skills and experience to determine this ratio and are not able to obtain a consistent performance quality out of these materials. Therefore, for the establishment of a board applicability of the water-hardening polyurethane waterproofing methods in construction sites, this study objectively analyzes the changes in the performance of these materials depending on the changes of the water mixture ratio and attempts to procure the optimal ratio on the basis of forming a provisionary standard. The study prepares mixtures of varying ratio(no water added, 5, 10, 15, 20, 25, 30, 40 and 50) and conducts comparative analysis respective mixtures' performances and their changes in the physical properties in an objective manner and proposes a provisional optimal value that can serve as a data base that can be used as a reference for future studies.

A Fundamental Study on Induction Technology of Separation Behavior Using Two-sided Adhesion of Joint of Composites Waterproofing System (시트-도막 복합방수공법의 접합부 2면 접착을 통한 분리거동 유도 기술에 관한 기초적 연구)

  • Park, Jin-Sang;Lee, Tae-Yang;Kim, Dong-Bum;Park, Wan-Goo;Heo, Neung-Hoe;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.212-219
    • /
    • 2015
  • This study focuses evaluating the efficiency and performance evaluation of composite type sheet-membrane waterproofing method that utilizes a separation behavior inducement system designed to resolve the chronic problems of disintegration and damage of overlap areas of waterproofing layers. As the result of the test, the tensile strength value was at 13.8N/mm and elongation rate at 587% for the separation behavior inducement type specimen, and the compared specimens had 14.2N/mm for tensile strength and 335% for elongation rate. For the separation behavior adhesion method specimen, when tensile stress or displacement occurred, the Zero-Span tension occurrence did not follow, which resulted in that the bottom sheet layer and the top membrane layer did not simultaneously becoming damaged. When undergoing the top and bottom layers were separated through separation behavior due to lack of flexibility, the bottom layer began to damage at the primary stage, and with the allowed boundary the upper membrane layer began to display flexibility and showed continuous displaced resulting in secondary phase damaging.

Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements (공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구)

  • Han, Yoon-Jung;Oh, Kyu-Hwan;Kim, Su-Ryon;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.379-387
    • /
    • 2016
  • In this study, a survey was conducted on the required measurement and waterproofing performance for residential building underground structure leakage prevention system. According to the results of the survey, it has been determined that leakage problem is considered to be quite severe, and many respondents have agreed. The legal guidelines and regulation systems do not reflect properly on the environmental requirements or conditions, resulting in continued leakage problem. In regards to this, a standardized waterproofing technique that can be used in underground areas of residential structures is required as an obligation and the development of high performance waterproofing method that allows for wet concrete surface adhesion and a guideline, design and maintenance method that allows the control of overall situational control of leakage is required.

Changes in surface roughness of bracket and wire after experimental sliding - preliminary study using an atomic force microscopy (브라켓과 탄선 간의 마찰 전후 표면 변화 분석 - 원자현미경을 이용한 예비연구)

  • Lee, Tae-Hee;Park, Ki-Ho;Jeon, Ji-Yun;Kim, Su-Jung;Park, Hun-Kuk;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.156-166
    • /
    • 2010
  • Objective: The surface roughness of orthodontic materials is an essential factor that determines the coefficient of friction and the effectiveness of tooth movement. The aim of this study is to evaluate the surface roughness change of the brackets and wires after experimental sliding quantitatively. Methods: Before and after experimental sliding tests, the surface roughness of stainless steel brackets, ceramic brackets, stainless steel wires, and beta-titanium (TMA) wires were investigated and compared using atomic force microscopy (AFM). Results: After sliding tests, changes in the surface of the wire were greater than changes in the bracket slot surface. The surface roughness of the stainless steel bracket was not significantly increased after sliding test, whereas the roughness of ceramic brackets was decreased. Both the surface roughness of stainless steel and TMA wires were increased after sliding test. More changes were observed on the ceramic bracket than the stainless steel bracket. Conclusions: AFM is a valuable research tool when analyzing the surface roughness of the brackets and wires quantitatively.

A Pilot Study on the Usefulness of Tomography and Bone Scan in Diagnosis of Patients with TMJ Osteoarthritis (측두하악관절 골관절염 환자의 진단에서 단층촬영과 골스캔 검사의 유용성에 대한 예비연구)

  • Kim, Cheul;Kim, Young-Jun;Moon, Ji-Hoi;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.2
    • /
    • pp.125-133
    • /
    • 2012
  • TMJ Osteoarthritis is a degenerative disease caused by overload on joint tissue, and often accompany with local tenderness on the joint, crepitus by mandibular movement, restriction of mandibular movement, and anterior openbite. In general, panoramic radiography, TMJ panoramic radiography, and transcranial radiography are conducted to diagnose osteoarthritis after clinical examination, however, these radiographic evaluations are limited in detecting minute bony changes of early pathologic lesion. The aim of this pilot study was to evaluate the limitation and usefulness of several TMJ imaging techniques, so we compare the findings from clinical examination, plain film radiographs, tomograph, and bone scan from 81 patients with temporomandibular joint disorder. The proportion of patients showing same findings in plain film radiographs, TMJ tomograph, and bone scan was high, however, it is desirable that clinician should conduct phased imaging examinations according to the clinical findings due to the possibilities of false negative findings in diagnosis of osteoarthritis.

Role of the periosteum on bone regeneration in rabbit calvarial defects (가토의 두개골 결손부에서 골재생에 끼치는 골막의 역할)

  • Jang, Hyun-Seon;Kim, Sang-Mok;Park, Joo-Cheol;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.939-948
    • /
    • 2005
  • The role of the periosteum on osteointegration of $Bio-Oss^{(R)}$(Geistlich, Wolhusen/Switzerland) was studied in rabbit calvarial defect. 12 New Zealand white male rabbits between 2.8 and 4 kg were included in this randomized, blinded, prospective study. Each rabbit was anesthetized with Ketamine HCl(5 mg/kg) and Xylazine HCl(1.5 ml/kg). An incision was made to the bony cranium and the periosteum was reflected. Using a 6-mm trephine bur(3i. USA), four 8-mm defects were created with copious irrigation. The defects were classified into barrier membrane($Tefgen^{(R)}$, Lifecore Biomedical. Inc, U.S.A.) only group as a control, $Bio-Oss^{(R)}$ with barrier membrane group, $Bio-Oss^{(R)}$ with periosteum covering group, and $Bio-Oss^{(R)}$ without periosteum covering group. There were 2 rabbits in each group. The wound was closed with resorbable suture materials. Rabbits were sacrificed using phentobarbital(100 mg/kg) intravenously at 1, 2, and 4 weeks after surgery. The samples were fixed in 4% paraformaldehyde, and decalcified in hydrochloric acid decalcifying solution(Fisher Scientific, Tustin, CA) at $4^{\circ}C$ for 2-4 weeks. It was embedded in paraffin and cut into 6 ${\mu}m$ thickness. The sections were stained with H & E and observed by optical microscope. The results were as follows; 1. The periosteum played an important role in osteointegration of $Bio-Oss^{(R)}$ in bone defects. 2. When the periosteum remained intact and $Bio-Oss^{(R)}$ was placed on the defect, $Bio-Oss^{(R)}$ with periosteum covering has been incorporated into the newly formed bone from 2-week postoperatively. 3. When the periosteum was removed at the surgical procedure, invasion of connective tissue took place among the granules, and new bone formation was delayed compared to periosteum covering group. Therefore, when the bone grafting was performed with periosteal incision procedure to achieve tension-free suture, the integrity of the overlying periosteum should be maintained to avoid fibrous tissue ingrowth.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.