• Title/Summary/Keyword: biomechanical system

Search Result 230, Processing Time 0.028 seconds

A Comparative Analysis of Biomechanical Factors and Premotor Time of Body Muscles between Elite College and Amateur Baseball Players during the Baseball Batting Motion

  • Lim, Young-Tae;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.205-211
    • /
    • 2016
  • Purpose: The aim of this study was to analyze biomechanical factors and PMT (premotor time) of body muscles between elite college and amateur baseball players during the baseball batting motion. Method: Kinematic and electromyographic data were obtained for 10 elite college baseball players and 10 amateur baseball players who participated in this study. All motion capture data were collected at 200 Hz using 8 VICON cameras and the PMT of muscles was recorded using a Delsys Trigno wireless system. The peak mean bat speed and the peak mean angular velocities of trunk, pelvis, and bat with PMT of 16 body muscles were computed. These kinematic and PMT data of both groups were compared by independent t-tests (p < .05). Results: The pelvis, trunk, and bat showed a sequence of angular velocity value during baseball batting. The PMTs of right tibialis anterior, left gastrocnemius, external oblique, and erector spinae were significantly different between the two groups. Conclusion: The PMT of body muscles was related to the shifting of body and rotation of the pelvis and the trunk segment, and this action can be considered the coordinated muscle activity of the lower and upper body.

Biomechanical Analysis of Throw Movement to Second Base in High School Elite Baseball Catchers (고등학교 야구 포수의 2루 송구 동작에 대한 운동역학적 분석)

  • Kim, Sung Yong;Park, Jong Chul;Byun, Kyung Seok;Baek, Hee Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.165-172
    • /
    • 2020
  • Objective: The purpose of this study was to provide quantitative and objective data of throwing movement in baseball catcher through biomechanical analysis. Method: Eight high school baseball catchers (age: 17.3±0.7 yrs, height: 175.3±4.5 cm, weight: 82.5±9.0 kg, Career: 7.4±2.1 yrs) participated and 3-dimentional motion capture system and electromyography (EMG) were used in this study. Results: The maximum center of mass position displacement was observed in forward direction. The linear velocity magnitude of the upper extremity segments were showed as "wrist>elbow>shoulder" which is indicative of kinematic chain. For kinetic EMG data, we also observed the greater muscle activation in the left brachioradial and erector spine muscles muscle that during throwing movement. Conclusion: We expect that biomechanical data from this study will provide important training implications to baseball coaches and trainers in order to effectively train their baseball catchers.

Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis (경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석)

  • Han, Paul;Jang, Young-Woong;Yoo, Oui Sik;Kim, Jung Sung;Kim, Han Sung;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.14-23
    • /
    • 2013
  • In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp., Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling, leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.

Biomechanical Analysis and Evaluation Technology Using Human Multi-Body Dynamic Model (인체 다물체 동역학 모델을 이용한 생체역학 분석 및 평가 기술)

  • Kim, Yoon-Hyuk;Shin, June-Ho;Khurelbaatar, Tsolmonbaatar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.494-499
    • /
    • 2011
  • This paper presents the biomechanical analysis and evaluation technology of musculoskeletal system by multi-body human dynamic model and 3-D motion capture data. First, medical image based geometric model and material properties of tissue were used to develop the human dynamic model and 3-D motion capture data based motion analysis techniques were develop to quantify the in-vivo joint kinematics, joint moment, joint force, and muscle force. Walking and push-up motion was investigated using the developed model. The present model and technologies would be useful to apply the biomechanical analysis and evaluation of human activities.

A Biomechanical Comparison of Cushioning and Motion Control Shoes During Running (달리기시 쿠션형과 모션컨트롤형 런닝화 착용에 따른 생체역학적 비교)

  • Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2005
  • Excessive pronation and impact force during running are related to various running injuries. To prevent these injuries, three type of running shoes are used, such as cushioning, stability, and motion control. Although there were may studies about the effect of midsole hardness on impact force, no study to investigate biomechanical effect of motion control running shoes. The purpose of this study was to determine biomechanical difference between cushioning and motion control shoes during treadmill running. Specifically, plantar and rearfoot motion, impact force and loading rate, and insole pressure distribution were quantified and compared. Twenty male healthy runners experienced at treadmill running participated in this study. When they ran on treadmill at 3.83 m/s. Kinematic data were collected using a Motion Analysis eight video camera system at 240 Hz. Impact force and pressure distribution data under the heel of right foot were collected with a Pedar pressure insole system with 26 sensors at 360 Hz. Mean value of ten consecutive steps was calculated for kinematics and kinetics. A dependent paired t-test was used to compare the running shoes effect (p=0.05). For most kinematics, motion control running shoes reduced the range of rearfoot motion compared to cushioning shoes. Runners wearing motion control shoe showed less eversion angle during standing less inversion angle at heel strike, and slower eversion velocity. For kinetics, cushioning shoes has the effect to reduce impact on foot obviously. Runners wearing cushioning shoes showed less impact force and loading rate, and less peak insole pressure. For both shoes, there was greater load on the medial part of heel compared to lateral part. For pressure distribution, runners with cushioning shoes showed lower, especially on the medial heel.

Impedance modulation of anthropomorphic robots with kinematic and force redundancies (여유자유도/여유구동 인체형 로봇의 임피던스 생성방식)

  • 이병주;김희국;이재훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1289-1292
    • /
    • 1997
  • Typical biomechanical system such as human body and mammals possess abundant muscles which are more than required for motion generation of such systems. We have shown that the excess number of muscles play important roles in spring-like impedance modulation. redundant kinematic structure, which is another feature of biomechanical systems, allows modulations of inertia and damping properties of such systems. In this work, we propose a frequency modulation algorithm which combines the spring-like impedance with inertia impedance. also, a load distribution method for frequency modulation is also introduced. The frequency modulation represents a simulataneous control of force and kinematic redundancies, which has not been addressed in the literature.

  • PDF

유니사이클 로봇의 주행경로를 변경하기 위한 퍼지룰의 구성

  • 김중완;안찬우;전언찬;한근조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.761-765
    • /
    • 1997
  • Our study of rider's postulator stability and tracking control on a unicycle began form the observation of a human riding. The system including unicycle and human operationg his unicycle is a fuzzy intelligent biomechanical model on basis of instinct and intuition search mechanisms. We proposed a robotic unicycle with one wheel and one body as a basic mode and derived equation of motion to this model. Our works is in making out fuzzy look-up table to control robotic unicycle. Fuzzy look-up table were determined for staight line and curve under reasonable inference emulating human's instinct and intuition riding a unicyale. Simulation results show that postulator stability and tracking control on both straight line and curve were successful by using proposed each fuzzy look-up table.

  • PDF

Biomechanical Assessment of Lifting Chair with Hip-up Function (힙업기능이 적용된 기립보조의자의 생체역학적 평가)

  • Bae, Ju-Hwan;Moon, In-Huyk
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.191-197
    • /
    • 2011
  • Lifting chair is a typical assistive product to aid for standing up and sitting down for persons with disability. It is particularly useful for the elderly persons whose muscular system is weakened by degenerative joint disease. This paper describes biomechanical assessments of lifting chair with hip-up function. In experiments we measured 3D motion and electromyographic(EMG) signal on the femoral muscle when subject performs the standing motion on the predetermined seat height. Based on assessment of the standing motion, we select the hip-up angle as 15 degrees to cover the relative femoral angle when EMG peak value is appeared. Using an implemented prototype lifting chair with hip-up function we perform standing experiments with five subjects. The experimental results show that the lifting and hip-up functions are effective to assist for standing up motion with less muscle force.