• Title/Summary/Keyword: biological signals transmission

Search Result 26, Processing Time 0.023 seconds

A Comparative Study of Compression Methods and the Development of CODEC Program of Biological Signal for Emergency Telemedicine Service (응급 원격 진료 서비스를 위한 생체신호 압축 방법 비교 연구 및 압축/복원 프로그램 개발)

  • Yoon Tae-Sung;Lim Young-Ho;Kim Jung-Sang;Yoo Sun-Kook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.311-321
    • /
    • 2003
  • In an emergency telemedicine system such as the High-quality Multimedia based Real-time Emergency Telemedicine(HMRET) service, it is very important to examine the status of the patient continuously using the multimedia data including the biological signals(ECG, BP, Respiration, $SpO_2)$ of the patient. In order to transmit these data real time through the communication means which have the limited transmission capacity, it is also necessary to compress the biological data besides other multimedia data. For this purpose, we investigate and compare the ECG compression techniques in the time domain and in the wavelet transform domain, and present an effective lossless compression method of the biological signals using PEG Huffman table for an emergency telemedicine system. And, for the HMRET service, we developed the lossless compression and reconstruction program or the biological signals in MSVC++ 6.0 using DPCM method and JPEG Huffman table, and tested in an internet environment.

Development of biological signal optical transmission system (생체신호처리용 광전송시스템 개발)

  • 박종대;손진우;서희돈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1933-1940
    • /
    • 1997
  • The development of CMOS IC chip and external system with optical transmission sytem is proposed in this paper, which deal with 4 subject 4 channel biological signals, receive and transmit biological signals to the external system using LED and infrared light of photodiode. This system decreases the dependency of power supply voltage to the COMS IC chip. A newenforce synchronization technique using infrared bi-directional communication has ben proposed. The telemetner IC with the size of $5.1{\times}5.1mm^2$ has the followingfunctions:receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated biological signals, transmission of modulated signals to external system, and auto power down control. To confirm the total telemetry system, electrocardogram is transmitted and received to the external system using optical link.

  • PDF

Force Transmission in Cellular Adherens Junction Visualized by Engineered FRET Alpha-catenin Sensor (형광공명에너지전이 알파카테닌 센서를 활용한 세포 부착접합부에서의 힘 전달 이미징)

  • Jang, Yoon-Kwan;Suh, Jung-Soo;Suk, Myungeun;Kim, Tae-Jin
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.366-372
    • /
    • 2021
  • Cadherin-Catenin complex is thought to play an essential role in the transmission of force at adherens junction. Due to the lack of proper tools to visualize and detect mechanical force signals, the underlying mechanism by which the cadherin-catenin complex regulates force transmission at intercellular junctions remains elusive. In this study, we visualize cadherin-mediated force transmission using an engineered α-Catenin sensor based on fluorescence resonance energy transfer. Our results reveal that α-catenin is a key force transducer in cadherin-mediated mechanotransduction at cell-cell junctions. Thus, our finding will provide important insights for studying the effects of chemical and physical signals on cell-cell communication and the relationship between physiological and pathological phenomena.

Low-power wireless communication System for Biosignal transmission (생체신호 무선 송수신을 위한 소형,저전력 통신시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Kim, Kyeong-Seop;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.370-372
    • /
    • 2005
  • Inconveniences which might arise in transmitting measured biological data based on cable protocols generally are recognized critical points in tele-monitoring environment and also restrict the mobility of the user. a. Especially, activity monitoring which is importantly recognized as a core parameter in ubiquitous healthcare arena and weight management, pervasive and wireless measuring technology is most needed. In this paper, we would like to suggest lower power, miniaturized communication system in order to solve the above problems. The suggested system is powered by small coin-size battery. Also, The suggested system is compared with a blue-tooth module which is generally available in the commercial market. Even though, the suggested system didn't have higher transmission rate, its low power consumption make the suggested system would be feasible in ubiquitous monitoring of biological signals in ubiquitous healthcare arena.

  • PDF

Development of the Lossless Biological Signal Compression Program for High-quality Multimedia based Real-Time Emergency Telemedicine Service (고품질 멀티미디어 기반 응급 원격 진료서비스를 위한 생체신호 무손실 압축, 복원 프로그램 개발)

  • Lim, Young-Ho;Kim, Jung-Sang;Yoon, Tae-Sung;Yoo, Sun-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2727-2729
    • /
    • 2002
  • In an emergency telemedicine system such as High-quality Multimedia based Real-time Emergency Telemedicine(HMRET) service, it is very important to examine the status of the patient continuously using the multimedia data including the biological signals(ECG, BP, Respiration, $SpO_2$) of the patient. In order to transmit these data real time through the communication means which have the limited transmission capacity. It is also necessary to compress the biological data besides other multimedia data. For the HMRET service, we developed the lossless biological signal compression program in MSVC++ 6.0 using DPCM method and JPEG Huffman table, and tested in an internet environment.

  • PDF

A Study On Implementation of the Telemedicine System (원격 진단시스템 구현에 관한 연구)

  • Choi, B.Y.;Lee, H.J.;Yoo, D.J.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.105-108
    • /
    • 1992
  • In this paper, we have implemented the telemedicine system which has a color image system and a biosignal processor. The inputted image is acquisited to 512 by 480 color image data. The col looted data is compressed to 1/5 of the original image data by using 1/5 and compression algorithm. A biological signals are inputted by 12 bit A/D converter into the system. In case of using 2400bps modem, a frame full color image data and biological information data needed 10 minutes in transmission.

  • PDF

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

A Study on the Biotelemetry using Infra-red Light (적외선을 이용한 생체신호의 원격측정에 관한 연구)

  • Huh, Soo-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.169-175
    • /
    • 1993
  • Recently, interest in infra-red(IR) telemetry has increased because of the entirely different propagation and reflection properties of IR light as compared to radiowaves. IR hardly penetrates most materials and is reflected from obstacles. An biotelemetry system using these characteristics of indirect transmitted IR lights was developed, in which 3 ECG's are multiplexed and modulated in PDM/PIM pulse sequence. This proto-type system enables us to realize the non-restraint measurement of biological signals. Compared with conventional radio telemetry, this technique has some merits such as no electromagnetic interference, no frequency allocation problem, no government control over transmission power.

  • PDF

Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function (무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현)

  • Lee, Sang-June;Kim, Myoung Nam;Lee, Jyung Hyun;Lim, Hyung-Gyu;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System (CDMA망 기반 3채널 심전도 모니터링 시스템의 평가)

  • Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.