A Portable Wireless EEG System for Neurofeedback: Design and Implementation

  • Chen, Hai-Feng;Ye, Dong-Hee;Kang, Young-Ho;Lee, Jung-Tae
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2007
  • Human can learn how to shape their brain electrical activity in a desired direction through continuous feedback of the electroencephalogram (EEG), and this technique is known as Neurofeedback (or EEG biofeedback), which has been used since the late 1960s in clinical applications. In this study, a portable wireless EEG (named wEEG) has been designed and implemented, which consists of a mobile station (a wireless two-channel EEG acquisition device) and a base station (a bridge between mobile station and computer). Moreover, a SensoriMotor Rhythm (SMR) training system was also implemented with the wEEG for enhancing attention with virtual environment. Experiment results based on 16 volunteers' (8 females and 8 males, average age is $27{\pm}4$) were reported in this paper. The results show that the SMR ratio of 87.5% subjects increased about 0.7% in training status than that in the stable status. With the proposed system, many training protocol scan be designed easily and can be done at home in our daily life conveniently. Additionally, the proposed system will be useful for disabled and aged people.

Geophysical and Sedimentological Characteristics of Lomilik Seamount, West Pacific (서태평양 Lomilik 해저산 퇴적환경 특성)

  • Lee, Hyun-Bok;Oh, Jae-Kyung;Park, Cheong-Kee;Chi, Sang-Bum;Kim, Jong-Uk;Moon, Jai-Woon;Nam, Sang-Heon
    • Ocean and Polar Research
    • /
    • v.26 no.2
    • /
    • pp.207-218
    • /
    • 2004
  • Lomilik Seamount in the west Pacific was seismically surveyed and photographed to illuminate the bottom topography, the condition of manganese crust, and the characteristics of sedimentary environment. Lomilik Seamount has a NW-SE elongated bottom topography with steep slopes in the NESW direction part. Even though the steep slopes of the seamount are devoid of deposits, the summit area and gentle slope of the seamount are covered with thick deposits. The seismic data indicate that Lomilik Seamount is a flat-topped and step-faulted guyot of volcanic origin. Deep-sea camera photographs show that much of the seafloor is rippled in symmetrical and asymmetrical patterns. The traces of biological activity were distinct on gentle seafloor suggesting the low-energy bottom conditions. Some photographs also show outcrops encrusted with manganese crusts. Sedimentary environments in the Lomilik Seamount appear have been governed by regional morphology and strong bottom current.

The Supervisory Control System in a Moving-Actuator type Total Artificial Heart: Thought and Progress

  • Om, K.S.;Ahn, J.M.;Lee, J.H.;Choi, J.H.;Kim, W.E.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.55-58
    • /
    • 1997
  • In this paper we reviewed and stated the present state of our team's research of the moving-actuator type total artificial heart (MA-TAH). Especially, this paper showed new direction of researches. The integrated research of battery, telemetry, TET is required. And the real-time supervisory of the state of hemodynamic variables and MA-TAH is also needed. These requirement made us to think the supervisory control system (SCS). As functional abilities of the SCS require very high computational cost, the digital signal processor is an appropriate choice for our need.

  • PDF

Research about Intelligent Snake Robot (지능형 뱀 로봇에 관한 연구)

  • Kim, Seong-Joo;Kim, Jong-Soo;Jeon, Hong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.70-75
    • /
    • 2003
  • There come various types of robot with researches for mobile robot. This paper introduces the multi-joint snake robot having 16 degree of freedom and composing of eight-axis. The biological snake robot uses the forward movement friction and the proposed artificial snake robot uses the un-powered wheel instead of the body of snake. To determine the enable joint angle of each joint, the controller inputs are considered such as color and distance using PC Camera and ultra-sonic sensor module, respectively. The movement method of snake robot is sequential moving from head to tail through body. The target for movement direction is decided by a certain article be displayed in the PC Camera. In moving toward that target, if there is any obstacle then the snake robot can avoid by itself. In this paper, we show the method of snake robot for tracing the target with experiment.

Determining differentially expressed genes in a microarray expression dataset based on the global connectivity structure of pathway information

  • Chung, Tae-Su;Kim, Kee-Won;Lee, Hye-Won;Kim, Ju-Han
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2004.11a
    • /
    • pp.124-130
    • /
    • 2004
  • Microarray expression datasets are incessantly cumulated with the aid of recent technological advances. One of the first steps for analyzing these data under various experimental conditions is determining differentially expressed genes (DEGs) in each condition. Reasonable choices of thresholds for determining differentially expressed genes are used for the next -step-analysis with suitable statistical significances. We present a model for identifying DEGs using pathway information based on the global connectivity structure. Pathway information can be regarded as a collection of biological knowledge, thus we are tying to determine the optimal threshold so that the consequential connectivity structure can be the most compatible with the existing pathway information. The significant feature of our model is that it uses established knowledge as a reference to determine the direction of analyzing microarray dataset. In the most of previous work, only intrinsic information in the miroarray is used for the identifying DEGs. We hope that our proposed method could contribute to construct biologically meaningful network structure from microarray datasets.

  • PDF

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • Heo, Seung-Jin;Kim, Gi-Beom;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF

Research Trends on Qigong in the Korean Journal (한국 저널에 게재된 기공관련 단일군 임상연구 동향 분석)

  • Park, Sun-Hee;Han, Chang-Hyun;Kim, Ki-Jin;Shin, Mi-Suk;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • Background: Qigong is one energy-healing intervention used to prevent and cure ailments and to improve health through regular practice. Although Qigong-neither itself nor its postulated mechanism of action-are within the paradigm of modern Western medical science. effects on the human body could be possible. Objectives: This study aims to review the bibliography, biological responses and therapeutic effects of Qigong. In the process, this review grasp trends in this field of studies and direct further researches into the right direction. Method: The computerized Korean databases were searched from their respective inception up to January 2008. The search terms used were 'Qi', 'Qigong', 'Doin', 'training', 'bioenergy', 'life nurturing' and random or Korean language terms related to qigong. Several specialized journals were also manually searched for relevant articles. Result: Since the 1990s, Qigong papers in the Korean Literature have been increased. Clinical research studies are among the most control design study. Research subjects are less patient than the general public. The most common treatment disease was Musculo-skeletal disorder. Conclusions: The depth study for the each Qigong is needed. Specifically, I think it should be a clinical studies and qualified research methods for evaluation are needed.

  • PDF

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

Intra-Motion Compensation Using CSRS method in MRI

  • Ro, Y.M.;Yi, J.H.;Cho, Z.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.377-382
    • /
    • 1994
  • In the conventional Fourier imaging method in MRI (Magnetic Resonance Imaging), intramotion such as pulsatile flow makes zipper-like artifact along the phase encoding direction. On the other hand, line-integral projection reconstruction (LPR) method has advantages such as imaging of short T2, object and reduction of the flow artifact by elimination of the flow-induced phase fluctuation. The LPR, however, necessarily requires time consuming filtering and back-projection processes, so that the reconstruction takes long time. To overcome the long reconstruction time of the LPR and to obtain the flow artifact reduction effect, we adopted phase corrected concentric square raster sampling (CSRS) method and improved its imaging performance. The CSRS is a fast reconstruction method which has the same properties with the LPR. In this paper, we proposed a new method of flow artifact reduction using the CSRS method. Through computer simulations and experiments, we verified that the proposed method can eliminate phase fluctuations, thereby reducing the flow artifact and re- markably shorten the reconstruction time which required long time in the LPR.

  • PDF

A Thoracic Model using Three-dimensional Finite Element Method (3차원 유한 요소법을 이용한 흉부 모델)

  • Deok-Won Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.57-62
    • /
    • 1987
  • A three-dimensional thoracic model was constructed using 8-node trilinear hexahedron elements. A three-dimensional steady-state finite element code was developed using FORTRAN. Its output consists of potential at each node. current In each element, and total current In each layer in the z-direction. The thoracic model was Implemented to calculate basal impedance(Zo) In Impedance CardiograPhy Generalized Laplace's equation was solved with Dirlchlet(constant potentials) and homogeneous Neumann(no flux) boundary conditions. It was found that the con structed thoracic model was reasonable since the calculated potential differences between the adjacent electrodes and basal impedance were about the same as the measured ones.

  • PDF