Journal of the Korea Academia-Industrial cooperation Society
/
v.3
no.4
/
pp.233-239
/
2002
The technology of joining BT (Biotechnology) with NT (Nanotechnology) must be rapidly arranged in 21c. Specially, the technical value is important more and more since the research about MEMS, which synthesizes BT and NT, is variously proceeding on the wide fields. This study by simulation shows the Fluid-Flow within micro Pump used in Bio-MEMS technology through Fluent Program. Namely, this experiment shows the most suitable external conditions and Pump Model within micro Pump by observing the flow of fluids as to the conditions of pressure, temperature and Model when the Fluid flows within micro Pump. We saw the variousness of pressure and temperature as to the existence of Chamber through examining by reference of Fluid-Flow. In the case of the existence of Chamber, the variousness of pressure and temperature is less than in the case of the non-existence of Chamber. By this simulation, we know that the Pump, which has a Chamber, affects the Fluid-Flow less than that. So we can say that it is necessary for us to design the Pump which has a Chamber.
Proceedings of the Korean Society of Precision Engineering Conference
/
2003.06a
/
pp.223-227
/
2003
A new flexible electronic packaging technology and its medical applications are presented. Conventional silicon chips and electronic modules can be considered as "mechanically rigid box." which does not bend due to external forces. This mechanically rigid characteristic prohibits its applications to wearable systems or bio-implantable devices. Using current MEMS (Microelectromechanical Systems) technology. a surface micromachined flexible polysilicon sensor array and flexible electrode array fer neural interface were fabricated. A chemical thinning technique has been developed to realize flexible silicon chip. To combine these techniques will result in a realization of truly flexible sensing modules. which are suitable for many medical applications.
Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.
Chang Jun Keun;Park Sung-Jin;Kim Jung Kyung;Han Dong Chul
Journal of the Korean Society of Visualization
/
v.1
no.1
/
pp.28-33
/
2003
This paper presents the visualization method in which 3-dimensional(3D) microchannel flow can be detected using a confocal scanning microscope. By soft-lithography, we fabricated various Bio-MEMS(Micro Electro-Mechanical System) devices such as a disposable microchip for a flow cytometer and a micro-mixer, which have 3D structures. Injecting aqueous fluorescent solution in the microfluidic devices, we measured the flow in a steady state by the confocal scanning microscope. At first, we explain the principle of the confocal scanning microscope. And then we show the results from 3D visualization of microscopic flow structures using the confocal scanning microscope.
Micromixer plays an important role in Bio-MEMS or ${\mu}-TAS$. Mixing is generally generated by turbulence and interdiffusion of two fluids. Because of low Reynolds number(Re << 2000) in ${\mu}-channel$, it is difficult to generate turbulence, so mixing mainly depends on interdiffusion. Thus long channel distance is required to mix two different fluids. To reduce the channel length required for mixing, we propose the a new active ${\mu}-mixer$ that two fluids are effectively mixed in ${\mu}-channel$ by the ultrasonic wave which is generated by PZT. The ultrasonic wave is radiated into a chamber in the cross-section directional direction to interface with the two fluids. The two fluids are positioned one on top of the other. Mixing state is measured by the changing of color due to the reaction of NaOH and phenolphtalein.
Journal of the Institute of Electronics Engineers of Korea SC
/
v.42
no.1
/
pp.33-37
/
2005
A micromixer plays an important role in Bio-MEMS or μ-TAS. Mixing is generally generated by turbulence and interdiffusion of two fluids. Because of low Reynolds number values (Re << 2000) within microchannels, it is difficult to generate turbulence, and consequently mixing mainly depends on interdiffusion. So, channel distance is often prohibitively long to mix two different fluids properly. To reduce this mixing length, we proposed a new mixer for micromixing in which two fluids were effectively mixed by an ultrasonic wave generated by PMN-PT. The ultrasonic wave was radiated into a chamber In the cross-sectional direction into the boundary surface formed by two fluids. The two fluids were positioned one on top of the other. The mixing state was measured by observing the color of samples due to the reaction of NaOH and phenolphthalein.
Application of MEMS to biologic system mainly categorized into bio-electronics and micro-medical systems, Bio-electronics concerns on the biocompatible electronic device, in-vivo sensors, the sensors based on biological materials, biological materials for electronics and optics, the concepts and materials Inspired by biology and useful for electronics, the algorithm inspired by biology, artificial sense, and the biologic-inorganic hybrids. Micro-medical systems are utilited into the drug delivery systems, micro patient monitoring systems, micro prosthesis and artificial organs, cardiology related prothesis, analysis systems, and the minimal invasive surgery tools based on the m icrom achining technology.
In this work, we optimized a microbolometer for application of a $CO_2$ detector by using MEMS technology. We fabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometer performance. We could fabricate more stable thermal isolation structure for the microbolometer through the results of ANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a $CO_2$ detector. The microbolometer shows a detectivity of $2.5{\times}109$ cmHz$^{1/2}$/W at a chopper frequency of 8 Hz and a bias current of $6.25\;{\mu}A$ with a vacuum package of about $3.0{\times}10.3$ torr. Therefore, we put to conclusion that the microbolometer optimized in this experiment could be useful for the application of a $CO_2$ detector.
Transactions on Electrical and Electronic Materials
/
v.17
no.3
/
pp.150-154
/
2016
Contact electrodes pose threats like inflammation, metal poisoning, and allergic reaction to the user during long term ECG procedure. Therefore, we present a novel noncontact electrocardiographic electrode designed through microelectromechanical systems (MEMS) process. The proposed ECG electrode consists of small inner and large outer circular copper plates separated by thin insulator. The inner plate enables capacitive transduction of bio-potential variations on a subject’s chest into a voltage that can be processed by a signal processing board, whereas the outer plate shields the inner plate from environmental electromagnetic noise. The electrode lead wires are also coaxially designed to prevent cables from coupling to ground or electronic devices. A prototype ECG electrode has an area of about 2.324 cm2, is very flexible and does not require power to operate. The prototype ECG electrode could measure ECG at about 500 um distance from the subject’s chest.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.