• Title/Summary/Keyword: bias effect

Search Result 1,492, Processing Time 0.031 seconds

Synthesis of Boron-Nitride Film by Plasma Assisted Chemical Vapor Deposition Using $BCl3-NH3-Ar$ Mixed Gas ($BCl3-NH3-Ar$계의 플라즈마화학증착공정을 이용한 질화붕소막의 합성)

  • 박범수;백영준;은광용
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.3
    • /
    • pp.249-256
    • /
    • 1997
  • The effect of process parameter of plasma assisted chemical vapor deposition (PACVD) on the variation of the ratio between cubic boron nitride (c-BN) and hexagonal boron nitride (h-BN) in the film was in-vestigated. The plasma was generated by electric power with the frequency between 100 and 500 KHz. BCl3 and NH3 were used as a boron and nitrogen source respectively and Ar and hydrogen were added as a car-rier gas. Films were composed of h-BN and c-BN and its ratio varied with the magnitude of process parameters, voltage of the electric power, substrate bias voltage, reaction pressure, gas composition, sub-strate temperature. TEM observation showed that h-BN phase was amorphous while crystalline c-BN par-ticle was imbedded in h-BN matrix in the case of c-BN and h-BN mixed film.

  • PDF

Effects of Psychosocial Interventions on Cortisol and Immune Parameters in Patients with Cancer: A Meta-analysis (암 환자에게 적용한 심리사회적 중재가 코티졸과 면역기능에 미친 효과: 메타분석)

  • Oh, Pok Ja;Jang, Eun-Su
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.4
    • /
    • pp.446-457
    • /
    • 2014
  • Purpose: This study was done to evaluate the effects of psychosocial interventions on cortisol and immune response in adult patients with cancer. Methods: MEDLINE via PubMed, Cochrane Library CENTRAL, EMBASE, CINAHL and domestic electronic databases were searched. Twenty controlled trials (11 randomized and 9 non-randomized trials) met the inclusion criteria with a total of 862 participants. Methodological quality was assessed using the Cochrane's Risk of Bias for randomized studies and the Risk of Bias Assessment tool for non randomized studies. Data were analyzed using the RevMan 5.2.11 program of Cochrane library. Results: Overall, study quality was moderate to high. The weighted average effect size across studies was -0.32 (95% CI [-0.56, -0.07], p=.010, $I^2 $=45%) for cortisol concentration, -0.62 (95%CI [-0.96,-0.29], p<.001, $I^2 $=0%) for T lymphocyte (CD3) and -0.45 (95%CI [-0.74, -0.16], p=.003, $I^2 $=0%) for Th lymphocyte (CD4) numbers. Psychosocial interventions were not effective for Tc lymphocyte (CD4), NK cell, monocyte, and cytokine response. Conclusion: Although these results provide only small evidence of successful immune modulation, they support the conclusion that psychosocial interventions can assist cancer patients in reducing emotional distress and improving immune response.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

Underwater Hybrid Navigation Algorithm Based on an Inertial Sensor and a Doppler Velocity Log Using an Indirect Feedback Kalman Filter (간접 되먹임 필터를 이용한 관성센서 및 초음파 속도센서 기반의 수중 복합항법 알고리듬)

  • 이종무;이판묵;성우제
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.6
    • /
    • pp.83-90
    • /
    • 2003
  • This paper presents an underwater hybrid navigation system for a semi-autonomous underwater vehicle (SAUV). The navigation system consists of an inertial measurement unit (IMU), and a Doppler velocity log (DVL), accompanied by a magnetic compass. The errors of inertial measurement units increase with time, due to the bias errors of gyros and accelerometers. A navigational system model is derived, to include the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 20. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors, and correct the state equation when the measurements are available. Simulation was performed with the 6-d.o,f equations of motion of SAUV, using a lawn-mowing survey mode. The hybrid underwater navigation system shows good tracking performance, by updating the error covariance and correcting the system's states with the measurement errors from a DVL, a magnetic compass, and a depth sensor. The error of the estimated position still slowly drifts in the horizontal plane, about 3.5m for 500 seconds, which could be eliminated with the help of additional USBL information.

The fabrication of Light Source for Fiber Optic Gyroscope (광섬유 자이로스코프용 광원 제작)

  • 정인식;안세경;배정철;최영규;홍창희
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.370-373
    • /
    • 2003
  • Superluminescent diodes(SLDs) are the optimum light sources for application in optical measurement systems such as fiber gyroscopes, optical time domain reflectometers, and to short and medium distance optical communication systems. The broadband characteristics of SLDs reduce Rayleigh backscattering noise, polarization noise, and the bias offset due to the nonlinear Kerr effect in fiber gyro systems. In this paper, in order to suppress lasing oscillation, we introduced a laterally tilted SCH(Separate Confinement Heterostructure)-SLD with a window region. An output power of 11mW has been achieved at 200mA injection current at 25$^{\circ}C$. At 120mA, parallel and perpendicular to the junction were 31$^{\circ}$${\times}$38$^{\circ}$.

  • PDF

테레비젼 신호중단에 있어 화질에 영향을 주는 요인에 관한 연구

  • 김원후
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.1 no.1
    • /
    • pp.23-31
    • /
    • 1976
  • When Television signal of VHF and UHF channel is retransmitted at the relay system with 6MHz Bandwidth including video and aural signals, the image is often affected with the unnatural changes of output amplitude frequency response within ttle region of dual sideband near to the carrier frequency. These phenomena are caused by the unnecessary lower sideband due to the spurious emission at the local oscillator, the nonlinear distortion in the linear amplifier, the intermoudulation distortion with the components of neighboring signal, the AM-PM conversion, and the envelope delay distortion. From the output characteristics, considering above results, the chief cause is caused by nonlinear response and has an effect on the bias states. Finally, it is confirmed that the effects on neighboring signal appear high in case of Down conversion than Up conversion and obtained the method for reducing the effects on the system.

  • PDF

Characterization and Emission/Absorption Study of a Grimm-type Glow discharge source in the application of high frequency Glow Discharge (고주파 글로우 방전을 이용한 GRIMM형 방전원의 특성 및 방출/흡광분석법 연구)

  • Suh, Jung-Gee;Woo, Jin-Chun
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.155-164
    • /
    • 1994
  • A conventional Grimm-type glow discharge source was constructed and applied to radio-frequency(13.56MHz) discharge for metal and ceramic analysis. We investigated the emission spectrum for aluminium and aluminium oxide and the influence of discharge operating paramaters including argon pressure, rf-power and DC-bias voltages at the sample-side electrode. Scanning Electron Microscope(SEM) also was used to investigate the effect of rf-sputtering on the microstructure formation of the aluminium oxide. Linear analytical calibration curves were constructed for Manganese and zinc element in samples of low alloy steel(BAS 401-405) and brass(NIST 1108-1117).

  • PDF

Chlorine effect on ion migration for PCBs under temperature-humidity bias test (고온고습 전원인가 시험에서 Cl에 의한 이온 마이그레이션 불량)

  • Huh, Seok-Hwan;Shin, An-Seob
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.47-53
    • /
    • 2015
  • By the trends of electronic package to be more integrative, the fine Cu trace pitch of organic PCB is required to be a robust design. In this study, the short circuit failure mechanism of PCB with a Cl element under the Temperature humidity bias test ($85^{\circ}C$/85%RH/3.5V) was examined by micro-structural study. A focused ion beam (FIB) and an electron probe micro analysis (EPMA) were used to polish the cross sections to reveal details of the microstructure of the failure mode. It is found that $CuCl_x$ were formed and grown on Cu trace during the $170^{\circ}C$/3hrs and that $CuCl_x$ was decomposed into Cu dendrite and $Cl_2$ gas during the $85^{\circ}C$/85%RH/3.5V. It is suggested that Cu dendrites formed on Cu trace lead to a short circuit failure between a pair of Cu traces.

A Fabrication and Characteristics of 16x8 Reflection Type Symmetric Self Electro-optic Effect Device Array (16x8 반사형 S-SEED 어레이 제작 및 특성)

  • 김택무;이승원;추광욱;김석태;정문식;김성우;권오대;강봉구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.10
    • /
    • pp.33-40
    • /
    • 1993
  • A reflection type 16x8 S-SEED array from LP(Low Pressure)-MODVD-grown GaAs/AlGaAs extremely shallow quantum well(ESQW) structures, with 4% Al fraction, has been fabricated. Its intrinsic region consists of 50 pairs of alternating 100.angs. GaAs and 100.angs. $Al_{0.04}$Ga$_{0.96}$As layers. A multilayer reflector stack of $Al_{0.04}$/Ga$_{0.96}$ As(599$\AA$)/AlAs(723$\AA$) was incorporated for the reflection plane below the p-i-n structures. The device processing after the MOCVD growth includes the mesa etching, isolation etching, insulator deposition, p & n metallization, and AR(Anti-Reflection) coating. For switching characteristics of the S-SEED in the form of p-i-n ESQW diode, the maximum optical negative resistance was observed at 856nm. Reflectance measurements showed a change from 15.6% to 43.3% for +0.9V to -6V bias. The maximum contrast ration of the S-SEED array was 2.0 and all the 128 devices showed optical bistability with contrast ratios over 2.4 at 5V reverse bias.

  • PDF

An Analytical Model for Deriving The Threshold Voltage of a Short-channel Bulk-type MOSFET (Short-Channel Bulk-Type MOSFET의 문턱전압 도출을 위한 해석적 모델)

  • Yang, Jin-Seok;Oh, Young-Hae;Suh, Chung-Ha
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.17-23
    • /
    • 2010
  • In this paper, a new analytical model for deriving the threshold voltage of a short-channel bulk-type MOSFET is suggested. Using the Fourier coefficient method, the Laplace equation in the oxide region and the Poisson equation in the depleted silicon region have been solved two-dimensionally. Making use of them, the minimum surface potential is derived to describe the threshold voltage. Simulation results show good agreement with the dependencies of the threshold voltage on the various device parameters and applied bias voltages.