• Title/Summary/Keyword: bending effect

Search Result 2,182, Processing Time 0.028 seconds

Effect of Oxide Film Formation on the Fatigue Behavior of Aluminum Alloy (알루미늄합금 재료의 산화막 형성이 피로거동에 미치는 영향)

  • Kim, Jong-Cheon;Cheong, Seong-Kyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, the effects of surface oxide film formation on the fatigue behavior of 7075-T6 aluminum alloy were analyzed in terms of the corrosion time of the alloy. The aluminum material used is known to have high corrosion resistance due to the passivation phenomenon that prevents corrosion. Aluminum alloys have been widely used in various industrial applications such as aircraft component manufacturing because of their lighter weight and higher strength than other materials. Therefore, studies on the fatigue behavior of materials and passivation properties that prevent corrosion are required. The fatigue behavior in terms of the corrosion time was analyzed by using a four-pointing bending machine, and the surface corrosion level of the aluminum material in terms of the corrosion time was estimated by measuring the surface roughness. In addition, fractographic analysis was performed and the oxide films formed on the material surface were studied by scanning electron microscopy (SEM). The results indicated that corrosion actively progressed for four weeks during the initial corrosion phase, the fatigue life significantly decreased, and the surface roughness increased. However, after four weeks, the corrosion reaction tended to slow down due to the passivation phenomenon of the material. Therefore, on the basis of SEM analysis results, it was concluded that the growth of the surface oxide film was reduced after four weeks and then the oxide film on the material surface served as a protection layer and prevented further corrosion.

Study on VHCF Fatigue Behaviors and UNSM Effects of Hydrogen Attacked STS 316L (수소취화된 스테인리스강 316L의 VHCF(Very High Cycle Fatigue) 피로특성과 UNSM 효과에 관한 연구)

  • Nahm, Seung-Hoon;Baek, Un-Bong;Suh, Chang-Min;Pyun, Young-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1011-1020
    • /
    • 2017
  • This study was conducted to investigate the material properties of stainless steel 316L specimens of untreated and UNSM treated material, hydrogen attacked material(100 bar, $300^{\circ}C$ at 120 h) and UNSM treated hydrogen attacked material at room temperature. Results demonstrated that the hydrogen attacked materials showed a tendency toward a slightly decreased fatigue strength, while the hydrogen embrittlement effect was smaller than the S-N curve of conventional untreated material. As compared to untreated material, the fatigue limit of the UNSM treated material increased by 43.8%, while it was 57.1% higher in the UNSM treated hydrogen attacked material than in untreated hydrogen attacked material. The plastic deformation layer was ${\sim}152{\mu}m$ thick, as confirmed by maps showing the level of local plastic deformation affected by the UNSM treatment in three ways: an image quality map, inverse pole figure map, and kernel average misorientation map captured via electron back scatter diffraction. Owing to hydrogen embrittlement, about 90% of surface cracks were smaller than the average grain size of $35{\mu}m$.

Experimental study on the damping characteristics of a cylindrical structure containing oil and bearing balls (윤활유와 베어링 볼을 내장한 원통형 구조물의 감쇠특성에 관한 실험적 연구)

  • 류봉조;송선호
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.107-114
    • /
    • 1996
  • The damping characteristics of a cylindrical structure containing oil and bearing balls is investigated for external bending forces. The experimental data obtained through the use of bearing balls with viscous oil in a column is given and analyzed. The viscous action of the oil and inertia effects of the balls on the inside of column create a drag force. The drag force dampens the vibration of the column. This study aims to search for an optimum combination of oil and balls which would produce maximum damping. Machining oils of various viscosities along with ball bearings of various sizes place inside cantilevered aluminium tubes of various diameters to create a rig on which the damping properties of the oil and balls can be studied. The contileved tubes are studied in both horizontal and vertical positions in order to gauge the effect of gravity on the system. The actions of the ball in the column and damping characteristics are investigated according to the dimensionless terms. The Buckingham theorem is used to reduce the variables and to predict the damping of an oil ball column. Though the damping ratio remains fairly constant in the horizontal position of column, the damping ratio begins to increase as the ratio of the number of balls and column length rise above 0.28 in the vertical position of oil ball column. The ratio of the ball diameter to column diameter influences the damping ratio with an optimum diameter ratio. Slenderness ratio and gravity effects on the damping ratio ane investigated.

  • PDF

Plastic Limit Loads for Slanted Circumferential Through-Wall Cracked Pipes Using 3D Finite-Element Limit Analyses (3차원 유한요소 한계해석을 이용한 원주방향 경사관통균열 배관의 소성한계하중)

  • Jang, Hyun-Min;Cho, Doo-Ho;Kim, Young-Jin;Huh, Nam-Su;Shim, Do-Jun;Choi, Young-Hwan;Park, Jung-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1329-1335
    • /
    • 2011
  • On the basis of detailed 3D finite-element (FE) limit analyses, the plastic limit load solutions for pipes with slanted circumferential through-wall cracks (TWCs) subjected to axial tension, global bending, and internal pressure are reported. The FE model and analysis procedure employed in the present numerical study were validated by comparing the present FE results with existing solutions for plastic limit loads of pipes with idealized TWCs. For the quantification of the effect of slanted crack on plastic limit load, slant correction factors for calculating the plastic limit loads of pipes with slanted TWCs from pipes with idealized TWCs are newly proposed from extensive 3D FE calculations. These slant-correction factors are presented in tabulated form for practical ranges of geometry and for each set of loading conditions.

A FINITE ELEMENT ANALYSIS ON STRESS AND DISPLACEMENT ACCORDING TO ISTHMUS WIDTH OF GOLD INLAY CAVITY (금인레이 와동의 폭경에 따른 응력분포와 변위에 관한 유한요소법적 연구)

  • Shin, Gang-Suk;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.395-411
    • /
    • 1993
  • The purpose of this study was to examine the clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, the cavities were prepared on maxillary first premolar and filled with gold inaly. A two - dimensional model was composed of 1037 - node triangle elements. In this model, isthmus was varied in width at 1/4, 1/3 and 1/2 of intercuspal width and material properties were given for four element groups, i.e., enamel, dentin, pulp and gold. The 500N occlusal load varied in direction and it was examined using three types of load : concentrated load, divided load and distributed load. The models were also examined with empty cavities using the devided load and distributed load. These models were analyzed the displacement and strees distribution by the two - dimensional Finite Element Method. The results were as follows : 1. All experimental models which filled with gold inlay after cavity preparation were similar direction of displacement with control model under same load type. But in the models with empty cavities, as isthmus width was wider, the degree of displacement was increased at same load type. 2. Among the experimental models which were filled with gold inaly after cavity preparation, the model II showed the least stress concentration under concentrated load and divided load. But in the models with empty cavities, the model III showed the largest stress concentration and tooth fracture is expected regardless isthmus width. 3. All experimental models showed similar displacement pattern beneath restorative material under a concentrated load. In the models with empty cavities, a divided load resulted in a lingual displacement of the lingual cusp, but a distributed load resulted in a buccal displacement of the lingual cusp. In regard to the above results, the restored models were stronger than empty models in respect to the bending moment and tensile stress. The empty models are expected to fracture regardless isthmus width. The safest isthmus width was 1/3 of intercuspal distance, which showed the least stress concentration in respect to the effect of stress distribution.

  • PDF

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

Characteristics of Shear Behavior of Reinforced Concrete Beams Strengthened with Near Surface Mounted CFRP Strips (CFRP 스트립 표면매립공법으로 보강된 철근콘크리트 보의 전단거동 특성)

  • Han, Sang Hoon;Hong, Ki Nam;Shin, Byoung Gil;Lim, Jin Mook;Kwak, So Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.178-189
    • /
    • 2011
  • Tests and analyses were performed in this study to assess the shear strength of Reinforced Concrete(RC) members strengthened by the Near Surface Mounted(NSM) technique in shear, which is drawing attention as an alternative to the Carbon Fiber Reinforced Polymer(CFRP) bonding strengthening technique. Four-point bending tests were performed on 7 RC specimens without any shear reinforcement. The test variables such as the inclination of CFRP strip (45 degrees and 90 degrees), and the spacing of CFRP strip (250mm, 200mm, 150mm, 100mm) were considered. Through the testing scenarios, the effect of each test variable on the failure mode and the shear strength of the RC members strengthened by the NSM technique in shear were assessed. The test results show that the specimens with CFRP strips at 45 degrees go to failure as a result of the strip fracture, but the specimens with CFRP strips at 90 degrees go to failure as a result of the slip of strips. Strips at 45 degrees was the more effective than strips at 90 degrees, not only in terms of increasing beam shear resistance but also in assuring larger deformation capacity at beam failure. In addition, the RBSN analysis appropriately predicted the crack formation and the load-displacement response of the RC members strengthened by the NSM technique in shear.

Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구)

  • Shin, Hyun-Seop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.10-21
    • /
    • 2014
  • The joint of prefabricated steel grid composite deck is composed of concrete shear key and high-tension bolts. The flexural and shear strength of the joint were experimentally evaluated only by the bending and push-out test of the joint element. In this study the lateral load transfer behavior of the joint in deck structure system is experimentally evaluated. Several decks connected by the joint are prefabricated and loaded centrically and eccentrically. In the case of centrically loaded specimens, the analysis results show that for the same loading step the rotation angle of the joint with 4 high-tension bolts is larger than the case of the joint with 9 high-tension bolts. Consequently, flexural stiffness of deck and lateral load transfer decrease in the case of specimen with 4 high-tension bolts. But, in the case of eccentrically loaded specimens, it is found that there are no significant differences in the load transfer behavior. The further analysis results about the structural behavior of the joint show that lateral load transfer can be restricted by the load bearing capacity of the joint as well as punching shear strength of the slab. Furthermore, considering that high-tension bolts in the joint didn't reach to the yielding condition until the punching shear failure, increase in the number of high-tension bolts from 4 to 9 has a greater effect on the flexural stiffness of the joint and deck system than the strength of them.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

Effects of Treatment Methods of Fire-retardant and Layup of Treated Veneers on the Performances of Plywoods (내화약제(耐火藥劑)의 처리방법(處理方法) 및 처리단판(處理單板)의 조판형태(調板形態)가 합판(슴板)의 성능(性能)에 미치는 영향(影響))

  • Son, Jung-Il;Cho, Jae-Sung;Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.39-50
    • /
    • 1999
  • This research was carried out to investigate the development of fire-retardancy treatment technology and performance evaluation of fire-retardant treated plywoods. Radiata pine, keruing, dillenia, calophyllum and terminalia veneers were treated by normal(conventional) pressure soak(NPS) and vacuum-pressure-soak(VPS) using 20% water solution of diammonium phosphate. Then, 4.8mm thick, 3ply plywoods were fabricated with combination of fire-retardant treated, untreated or water-immersion types and several composition types of radiata pine and keruing veneers, i,e. the uniform and the mixed types in species composition, and the homogenious and the alternate layer types in veneer treatment. In composed species, the retention and the treatment effects of fire-retardant chemicals III radiata pine was still greater than those of keruing. The effect of VPS treatment was larger than that of NPS treatment, however, adhesive bonding strength and bending strength of plywoods treated by these two methods were not necessarily lowered, compared to those of untreated plywood. And also, fire endurance performance of the urea melamine resin-bonded plywood was greater than that of the phenol resin-bonded plywood. In result, the appropriate combination in veneer species and layer as well as alternate fire-retardant treatments would be more efficiently available in service.

  • PDF