• Title/Summary/Keyword: beam spot

Search Result 286, Processing Time 0.027 seconds

Time-resolved transient reflective image on silicon surface after single-shot fs-laser pulse irradiation (단일 펨토초 레이저펄스를 이용한 실리콘 표면에서의 시분해 반사율 측정 연구)

  • Moon, Heh-Young;Sidhu, Mehra Singh;Lee, Hyun-Kyu;Jeoung, Sae-Chae
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • In this work, we have studied on time-resolved transient reflective image of single crystalline Si surface after single-shot fs-laser irradiation with varying the laser fluence under two different laser spot sizes. The temporal profiles of transient reflectivity changes as well as its maximum values at the early delay time were found to be strongly dependent on both the laser beam spot size and laser fluence. We have interpreted the dependence of transient reflectivity changes on the laser spot size in terms of a relaxation of the generated free carriers to the bulk silicon, which should be interacted with the plasma.

  • PDF

Simulation of Beta Rays from Tritium with Cathode Rays (음극선을 이용한 삼중수소 베타선 모사)

  • Kim, KwangSin;Lee, Sook-Kyung;Son, Soon-Hwan;Lim, Hoon;Lee, Dong-Hwan
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.141-148
    • /
    • 2008
  • Beta rays emitted from tritium in titanium tritide film were simulated with cathode rays of a scanning electron microscope to investigate the effect of beta rays from tritium on semiconductor devices. The cathode ray currents, which vary with the change of applied energy and beam spot size, were measured with Faraday cup. The current from the semiconductor device irradiated with cathode rays at various conditions was measured. The cathode ray current increased with the increase of spot size to a maximum then decreased when the spot sized increased further. The magnitude of current produced in the semiconductor device is proportional to the magnitude of cathode ray current. The magnitude of cathode ray current at each energy level was matched to the intensity of beta ray to simulate the tritium beta ray spectrum. Then the semiconductor characteristics were analyzed with I-V curves.

Fairness-Based Beam Bandwidth Allocation for Multi-Beam Satellite Communication System (다중 빔 위성 통신 시스템을 위한 공평성 기반 빔 대역폭 할당)

  • Jung, Dong-Hyun;Ryu, Joon-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1632-1638
    • /
    • 2020
  • In this paper, we investigate a multi-beam satellite communication system where multiple terminals transmit information signals to the gateway via a satellite. The satellite is equipped with phased array antennas to form multiple spot beams of which bandwidths are not identically allocated. We formulate an optimization problem to maximize fairness of beam bandwidth allocation. In order to solve the problem, we propose two heuristic algorithms; iterative beam bandwidth allocation (IBBA) and request ratio-based beam bandwidth allocation (RRBBA) algorithms. The IBBA algorithm iteratively equalizes the ratio of allocated bandwidth of each beam to their resource request while the RRBBA algorithm allocates beam bandwidth calculated from the ratio. Simulation results show that the IBBA algorithm has close fairness performance to the optimum while the RRBBA algorithm has less performance than the IBBA algorithm at the price of reduced computational complexity.

A Study on the Laser Lamination Joining of Silicon Steel Sheets with Die (금형내의 레이저에 의한 규소강판 적층가공에 관한 연구)

  • Kang, H.S.;Kang, I.T.;Jun, T.O.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.37-43
    • /
    • 1997
  • The technology of Laser lamination joining of silicon steel sheets has been studied in this paper. Conventional sheets lamination process does not meet the requirments for the improvement electric parts performance. In response to this, a new Laser spot joining method has been developed. This study performs the Laser spot lamination joining while synchronizing the sillicon steel sheets in the dies with the press movement. Several conclusions have been drawn in this paper. Effects of beam focus, power, atmosphere gas and press oil etc.

  • PDF

Implementation of multi-level phase gratings for the optical interconnection using liquid crystal television (LCTV를 이용한 광연결용 다위상 격자의 구현)

  • Lee, Yeon-Seon;Kim, Nam;Park, Seong-Gyoon;Ihm, Jong-Tae
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.3
    • /
    • pp.152-162
    • /
    • 1996
  • Diffraction gratings were designed to generate multiple beams for the real-time optical interconnection in free-space using a liquid crsytal television. Multi-level phase gratings consisted of stepped phase value, 0 to 2$\pi$, and generate a 5$\times$5 spot array, and V-shaped spot patterns which have a maximum diffraction efficiency of 78.84%. Simulated annealing technique was used to determine phase states of each pixel having uniform intensity and high diffraction efficiency. Through the optical interconnection experiments, we compared the diffraction characteristics of beam paterns obtained by binary-level, four-level, and eight-level phase gratings.

  • PDF

Optimal Design of NFR Coarse Actuator (근접장 광기록 장치용 조동 구동기의 최적 설계)

  • 정재화;이성규;김기현;권대갑
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.592-596
    • /
    • 2001
  • Near field technology makes it possible to overcome the diffraction limit of laser beam and create the small spot. Because of the small spot size, the pit size and track pitch can be decreased. So the high performance actuator is needed for near field recording system. And the light mass and the small form factor are also important properties of the NFR actuator in order to be used for hand held device. The purpose of this paper is the optimal design of the NFR coarse actuator to maximize actuating force. The structure of NFR coarse actuator is the same as HDD VCM actuator. The permeance method is used for modeling of the coarse actuator. The optimal result and the FEM simulation result are presented.

  • PDF

Design and Fabrication of Microlens Illuminated Aperture Array for Optical ROM Card System (Optical Card 시스템에서의 마이크로렌즈 조사 광프로브 어레이 설계 및 제작)

  • Kang, Shin-Ill;Kim, Seok-Min;Kim, Hong-Min;Lee, Jee-Seung;Lim, Ji-Seok;Busch, Christopher
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • An optical ROM card system which using an optical probe array generated by Talbot effect was proposed as new robust storage solution. To improve the optical density and to decrease the power consumption of the system, it is very important to make the spot sizes of optical probes smaller as well as to increase the optical efficiency from the light source to optical probes. In this study, a microlens illuminated aperture array for generating high efficiency optical probe away with small beam spot was designed and fabricated using monolithic lithography integration method. The maximum intensity of optical probes of microlens illuminated aperture array increased about 12 times of that of aperture array, and the full width half maximum of the optical probe at Talbot plane generated by microlens illuminated aperture array was $0.77{\mu}m$.

  • PDF

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

Finite Element Analysis for Electron Optical System of a Thermionic SEM (열전자방사형 주사전자 현미경 전자광학계의 유한요소해석)

  • Park, Keun;Jung, Huen-U.;Kim, Dong-Hwan;Jang, Dong-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1293
    • /
    • 2007
  • The present study covers the design and analysis of a thermionic scanning electron microscope (SEM) column. The SEM column contains an electron optical system in which electrons are emitted and moved to form a focused beam, and this generates secondary electrons from the specimen surfaces, eventually making an image. The electron optical system mainly consists of a thermionic electron gun as the beam source, the lens system, the electron control unit, and the vacuum unit. In the design process, the dimension and capacity of the SEM components need to be optimally determined with the aid of finite element analyses. Considering the geometry of the filament, a three-dimensional (3D) finite element analysis is utilized. Through the analysis, the beam emission characteristics and relevant trajectories are predicted from which a systematic design of the electron optical system is enabled. The validity of the proposed 3D analysis is also discussed by comparing the directional beam spot radius. As a result, a prototype of a thermionic SEM is successfully developed with a relatively short time and low investment costs, which proves the adoptability of the proposed 3D analysis.

  • PDF

Optimization of optical focus of composition optical system by OSLO (합성광학계의 OSLO를 통한 optical focus의 최적화)

  • Kim, Dae Nyoun;Choi, Gei Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • This study was to calculate spot size, focus shift and optical focus by use of OSLO when 3 wavelength, ${\omega}{\upsilon}_1=0.588{\mu}$, ${\omega}{\upsilon}_2=0.486{\mu}$ and ${\omega}{\upsilon}_3=0.656{\mu}$ in composite lens optics system & ocular optical system were respectively here, Entrance Beam Radius(mm) 1 mm, Field angle(deg) 5.7296e-0.5 mm, Image Aperture 0.053055 mm, Exit Aperture 0.903711 mm, Reflective focal length 25.181544 mm, Petzval radius -19.21839 mm, n = 1.523. It was found that a range of spot size was 0.002 mm~0.07 mm when a range of back curvature radius was 1 mm~30 mm, and 0.0005 mm~0.002 mm when of it more than 50 mm. Focus shift, 50 mm a range 3 kinds of lens was small, and it saw that of all tendency was high up to 1 mm~15 mm and up to 25 mm beyond that limits, it was going down and then going up again, optical focus 100 mm lens was best and the value when optimization with this lens was $60{\pm}1mm$.

  • PDF