• 제목/요약/키워드: beam quality

검색결과 1,050건 처리시간 0.026초

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Comparison of Quality of Bologna Sausage Manufactured by Electron Beam or X-Ray Irradiated Ground Pork

  • Shin, Mee-Hye;Lee, Ju-Woon;Yoon, Young-Min;Kim, Jong Heon;Moon, Byeong-Geum;Kim, Jae-Hun;Song, Beom-Suk
    • 한국축산식품학회지
    • /
    • 제34권4호
    • /
    • pp.464-471
    • /
    • 2014
  • Ground lean pork was irradiated by an electron beam or X-rays to compare the effects of two types of radiation generated by a linear accelerator on the quality of Bologna sausage as a model meat product. Raw ground lean pork was vacuum packaged at a thickness of 1.5 cm and irradiated at doses of 2, 4, 6, 8, or 10 kGy by an electron beam (2.5 MeV) or X-rays (5 MeV). Solubility of myofibrillar proteins, bacterial counts, and thiobarbituric acid reactive substance (TBARS) values were determined for raw meat samples. Bologna sausage was manufactured using the irradiated lean pork, and total bacterial counts, TBARS values, and quality properties (color differences, cooking yield, texture, and palatability) were determined. Irradiation increased the solubility of myofibrillar proteins in a dose-dependent manner (p<0.05). Bacterial contamination of the raw meat was reduced as the absorbed dose increased, and the reduction was the same for both radiation types. Differences were observed only between irradiated and non-irradiated samples (p<0.05). X-ray irradiation may serve as an alternative to gamma irradiation and electron beam irradiation.

A Psychophysical Approach to the Evaluation of Perceived Focusing Quality of CRT Displays

  • Yoon, Kwang-Ho;Kim, Sang-Ho;Chang, Sung-Ho
    • Journal of Information Display
    • /
    • 제5권3호
    • /
    • pp.35-40
    • /
    • 2004
  • In this study, we collected data used to formulate the relationship between quantitative metrological parameters in CRT display and the perceived focus quality. Human perception of the focusing quality was evaluated in terms of user feedback scores regarding the character legibility from four highly trained inspectors. Thirteen CRT monitors from five different manufacturers were compared relatively with respect to the norm monitor. The profile of electron beam such as spot size and the shape of distribution made by electron beam, contrast, convergence of RGB beams, and luminance characteristics were measured using a precision measurement system. Linear regression analysis and artificial neural network models were used to formulate the relationship between human perception and the quantitative measurements. The accuracy of the formulated linear regression model ($R^2$=0.515) was not satisfactory but the nonlinear neural network model ($R^2$=0.716) was fairly convincing and robust even the utilized data included subjective differences.

RF-MEMS 스위치용 마이크로 외팔보의 감쇠특성 (Damping Characteristics of a Microcantilever for Radio Frequency-microelectromechanical Switches)

  • 이진우
    • 한국소음진동공학회논문집
    • /
    • 제21권6호
    • /
    • pp.553-561
    • /
    • 2011
  • A theoretical approach is carried out to predict the quality factors of flexible modes of a microcantilever on a squeeze-film. The frequency response function of an inertially-excited microcantilever beam is derived using an Euler-Bernoulli beam theory. The external force due to squeeze-film phenomenon is developed from the Reynolds equation. Slip boundary conditions are employed at the interfaces between the fluid and the structure to consider the gas rarefaction effect, and pressure boundary condition at both ends of fluid analysis region is enhanced to increase the exactness of predicted quality factors. To the end, an approximate equation is derived for the first bending mode of the microcantilever. Using the approximate equation, the quality factors of the second and third bending modes are calculated and compared with experimental results of previously reported work. The comparison shows the feasibility of the current approach.

전자선 조사가 포장방법에 따른 건미역(Undaria pinnatifida)의 미생물학적 안전성 및 품질변화에 미치는 영향 (Effect of Packaging and Electron Beam Irradiation on the Microbial Safety and Quality of Dried Undaria pinnatifida)

  • 박시우;김꽃봉우리;김민지;강보경;박원민;김보람;안나경;최연욱;이주운;김재훈;변명우;안동현
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.489-494
    • /
    • 2014
  • This study determined the effect of packaging and electron beam irradiation on the quality of dried Undaria pinnatifida. Samples were air or vacuum packaged and irradiated at 7 kGy. The dried Undaria pinnatifida had total viable cells and coliform counts of 5.51 and 4.40 log CFU/g in total, respectively, and counts of 5.56 and 4.19 log CFU/g in surface. These counts were reduced by 2-4 log cycles after irradiation. Irradiation increased the lightness and yellowness of the dried Undaria pinnatifida, but not the redness. In the sensory evaluation, there were no significant differences among samples. Therefore, electron beam irradiation improves the microbial safety and quality of dried Undaria pinnatifida.

구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구 (A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose)

  • 박윤희;박지군
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.303-308
    • /
    • 2022
  • 유방암의 조기 진단에는 X선을 이용한 유방 촬영이 현재 가장 많이 이용되고 있다. X선 장치의 사용 빈도가 증가함에 따라 유방 X선 촬영에서 기인하는 방사선의 위해해 대한 관심이 고조되고 있는 추세이다. 이에 본 연구에서는 고 대조도 및 고해상력을 요구하는 X선 유방촬영에서 유선의 피폭선량을 측정하기 위하여 International Atomic Energy Agency (IAEA)에서 규정한 검사 기준에 대해 IEC 62220-1-2에서 제시하는 국제 권고안의 beam quality 기준을 바탕으로 평균 유선 선량을 평가하는 가이드라인을 제시 하고자 하였다. 그 결과 4.5 cm PMMA 팬톰의 평균 유선선량 값은 30 kV 범위 이내에서 최대 2.3 mGy였으며, 28 kV를 기준으로 1.19 mGy로 평가되었다.

Development and Evaluation of an Electron Beam Source for Microscopy and Its Applications

  • Ahn, Seung-Joon;Oh, Tae-Sik;Kim, Ho-Seob;Ahn, Seong-Joon
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.127-130
    • /
    • 2010
  • We have developed an efficient electron beam (e-beam) source, a microcolumn, that can be used as a source module for of microscopy and its applications. To obtain a low operating voltage, a very sharp cold field electron emitter was developed by electrochemically etching a tungsten wire. Laser diffraction was used for the fabrication of high-quality electron lenses and for their precise alignment. The measurement of the e-beam currents, and SEM images captured by the microcolumn confirmed the potential of the device as a very good e-beam source.

Finite element modeling of slab-on-beam concrete bridge superstructures

  • Patrick, Michael D.;Huo, X. Sharon
    • Computers and Concrete
    • /
    • 제1권3호
    • /
    • pp.355-369
    • /
    • 2004
  • This paper presents a study of four finite element techniques that can be used to model slabon-beam highway bridges. The feasibility and correctness of each modeling technique are examined by applying them to a prestressed concrete I-beam bridge and a prestressed concrete box-beam bridge. Other issues related to bridge modeling such as torsional constant, support conditions, and quality control check are studied in detail and discussed in the paper. It is found that, under truck loading, the bending stress distribution in a beam section depends on the modeling technique being utilized. It is observed that the behavior of the bridge superstructure can be better represented when accounting for composite behavior between the supporting beams and slab.