• 제목/요약/키워드: beam quality

검색결과 1,057건 처리시간 0.043초

UV 레이저 마이크로머시닝을 이용한 마이크로 채널 제작기술 (Micro Channel Fabrication Technology Using UV Laser Micromachining)

  • 양성빈;장원석;김재구;신보성;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.216-224
    • /
    • 2004
  • In this study, we have developed a new UV$({\lambda}=355nm)$ laser micromachining technology by direct ablation method without masks. This technology allows that 3D micro parts can be fabricated rapidly and efficiently with a low price. And it has a benefit of reducing fabricating process simply. Due to micro parts' fabrication, such technologies need the control of XYZ stages with high precision, the design of optical devices to maintain micron spot sizes of laser beam and the control technology of laser focus. The developed laser manufacturing process for laser micromachining is that, after extracting coordinates of shape data from CAD model data, a beam path considering manufacturing features of laser beam is created by using genetic algorithm. This generated manufacturing process is sent to stage controller. In order to improve the surface quality of micro parts, we have carried out experiments on iteration manufacturing and beam step-over by using a minimum focus size. Moreover, we have fabricated a micro-channel through the developed laser micromachining technology and verified it through the results.

보 요소와 비선형 스프링 특성을 이용한 버스 전복 해석 (Rollover Analysis of a Bus using Beam Element and Nonlinear Spring Characteristics)

  • 박수진;유완석;권연주;김진배
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.56-63
    • /
    • 2007
  • In case of bus rollover, the body structure of the bus should be designed to ensure the survival space for passengers. So, this study focuses on evaluating rollover strength through a computer simulation using the commercial code, LS-DYNA3D at the initial stage of vehicle development. For this study, section structure was modeled using a simple beam element, and impact boundary conditions required by ECE(Economic Commission for Europe) regulation No.66 were applied. In order to confirm the validity of the beam element bus model, the results compared with the test results and shell element bus model. The analysis errors from beam element bus model are due to the difference in strain energy of joint area between beam and shell model. In this study, a method for the joint modeling was suggested by using nonlinear springs to which the collapse mechanisms were applied.

TiN증착 조건에 따른 박막의 특성에 대한 실험적 연구 (A study on an experimental basis a special quality character of thin film use in order to TiN a conditioned immersion)

  • 박일수
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.4711-4717
    • /
    • 2011
  • PVD방식에 의한 TiN박막의 형성은 DC와 RF sputtering deposition 방식을 적용할 수 있지만, 플라즈마 생성을 위해 주입된 가스의 이온화율이 떨어져 박막성형 속도가 느려지며, 박막과의 접착력을 높이는 것에도 한계성을 가지고 있다. 이를 개선하기 위해 증착과 동시에 이온빔을 조사하는 이온빔 진공증착 IBAD(Ion beam assisted deposition)를 이용 하게 되면, 코팅 전에 소재 표면을 Ion beam으로 조사하기 때문에 표면cleaning의 효과가 크고, 접착력이 높은 박막을 얻을 수 있다. 또한 고 진공과 낮은 온도에서도 균일한 두께의 고순도의 박막을 얻을 수 있는 이점이 있다.

대전지역 직달 및 산란과 전일사 상관계수 (Beam and Diffuse to Global Solar Irradiation Correlation Coefficients for Daejeon)

  • 이관호;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.11-24
    • /
    • 2019
  • The total solar irradiation on horizontal surfaces is separated into the beam and diffuses components. Although horizontal global irradiance is a commonly measured parameter for many sites, horizontal diffuse irradiance is not so readily obtainable. For such sites that measure global irradiation alone, a simple but reasonably accurate method is required to estimate diffuse irradiance from its global counterpart. This study investigates the applicability of correlation coefficients models correlating hourly diffuse and beam fraction and hourly clearness index in Daejeon. The three diffuse to global correlation coefficients models (Orgill and Holland model, CIBSE Guide J model, and Erbs et al. model) are selected and the three modified beam to global correlation coefficients models are generated. MBE, RMSE, r-squared of Daejeon and Daejeon boundary site-fitted models are compared with the case of original coefficients. The comparison result shows that the beam and diffuse to global solar irradiation correlation coefficients models with boundary site-fitted coefficients are best suitable for Daejeon. Further researches will be conducted to find the boundary site-fitting method using measured data of other cities and correlation coefficients models using solar altitude, cloud cover, and sunshine duration.

레이저광 반사 화상을 이용한 표면 거칠기 측정법의 개발과 적용 (Development of a Surface Roughness Measurement Method Using Reflected Laser Beam Image and Its Application)

  • ;김화영;안중환;최이존
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.51-57
    • /
    • 2001
  • A light beam reflected from a machined surface generally containes information concerning about its surface roughness. This study examines and proposes a surface roughness measurement technique for on-machine measurement of machined surfaces. The technique is based on the measurement of a reflected laser beam pattern and the statistical analysis of its light intensity distribution. The surface roughness was found to be closely related to the standard deviation of the light intensity on the primary axis of the reflected pattern. An image acquisition device is made up of a laser diode, a half mirror, a screen, and a CCD camera. The exact image with the primary and secondary axes of a reflected laser beam pattern is calculated through such image processing algorithm as thresholding, edge detection, image rotation, segmentation, etc. A median filter and a surrounding light correction algorithm are improve the image quality and reduce the measuring error. Using the developed measuring device the effect of screen materials and workpiece and workpiece materials was investigated. Experimental results regarding to relatively high-quality surfaces machined by grinding, polishing, lapping processes have shown the measurement error is within 10% in the range of $0.1{mu}m~0.8{\mu}m R_q.$Therefore, the proposed method is thought to be effectively used when quick measurements is needed with workpieces fixed on the machine.

  • PDF

임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량 (Radiation Doses and Quality Assurance in Cone Beam CT(CBCT))

  • 최용석;김규태;황의환
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.

Synergistic Effects of Electron-beam Irradiation and Leek Extract on the Quality of Pork Jerky during Ambient Storage

  • Kim, Hyun-Joo;Kang, Mingu;Yong, Hae In;Bae, Young Sik;Jung, Samooel;Jo, Cheorun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권4호
    • /
    • pp.596-602
    • /
    • 2013
  • To investigate the synergistic effect(s) of electron-beam (EB) irradiation and leek (Allium tuberosum Rottler) extract on the quality of pork jerky during ambient storage, we irradiated prepared pork jerky samples (control and samples with 0.5% and 1.0% leek extract) with EB technology at doses of 0, 1, 2, and 4 kGy, stored them for 2 months at $25^{\circ}C$, and analyzed them. Water activity was 0.73 to 0.77 in non-irradiated samples, and no significant difference in the water activity was observed between the samples treated with leek and the control. The total aerobic bacterial count was significantly decreased with an increase in the irradiation dose and leek extract addition when compared to that of the control ($4.54{\pm}0.05$ log CFU/g). Further, the Hunter color values ($L^*$, $a^*$, and $b^*$) were found to be significantly decreased following leek extract addition and EB irradiation. However, the color values, especially the $a^*$ value of the irradiated samples significantly increased during storage. Notably, increasing the EB irradiation dose enhanced the peroxide value. Sensory evaluation revealed that irradiation decreased flavor and overall acceptability. Our findings suggest the use of EB irradiation in combination with leek extract to improve the microbiological safety of pork jerky. However, in order to meet market requirements, novel methods to enhance the sensory quality of pork jerky are warranted.

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

서브 미크론의 패턴으로 구성된 고효율 회절 렌즈 몰드 제작 (Fabrication of High-Quality Diffractive-Lens Mold having Submicron Patterns)

  • 우도균;하네 카즈히로;이선규
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1637-1642
    • /
    • 2010
  • 본 연구는 초슬림의 광학 시스템에 적용 가능한 서브 미크론의 패턴으로 구성된 고효율 회절 렌즈의 금형을 가공하는 방법에 관한 것이다. 서브미크론의 패턴으로 구성된 고효율 회절 렌즈를 가공하기 위해 분해능이 뛰어난 전자빔 노광장치와 고속 원자 빔 플라즈마 에칭 공정을 바탕으로 다중 정렬방식을 이용하였다. 다중 정렬 방식을 이용하여 고효율 회절 렌즈를 가공 하기 위해서는 정렬 오차, 노광 오차 그리고 에칭 오차를 최소화 해야만 한다. 본 연구에서는 이 주요한 세 가지 가공 오차를 최소화 하였으며, 이를 바탕으로 지름 $267\;{\mu}m$ (NA=0.25), 최소 선 폭 226 nm, 렌즈 두께 819 nm 를 가지는 고효율 회절 렌즈 가공을 실현 하였다.

Apical periodontitis in mesiobuccal roots of maxillary molars: influence of anatomy and quality of root canal treatment, a CBCT study

  • Samantha Jannone Carrion;Marcelo Santos Coelho;Adriana de Jesus Soares;Marcos Frozoni
    • Restorative Dentistry and Endodontics
    • /
    • 제47권4호
    • /
    • pp.37.1-37.9
    • /
    • 2022
  • Objectives: This study aimed to evaluate the prevalence of apical periodontitis (AP) in the mesiobuccal roots of root canal-treated maxillary molars. Materials and Methods: One thousand cone-beam computed tomography images of the teeth were examined by 2 dental specialists in oral radiology and endodontics. The internal anatomy of the roots, Vertucci's classification, quality of root canal treatment, and presence of missed canals were evaluated; additionally, the correlation between these variables and AP was ascertained. Results: A total of 1,000 roots (692 first molars and 308 second molars) encompassing 1,549 canals were assessed, and the quality of the root canal filling in the majority (56.9%) of the canals was satisfactory. AP was observed in 54.4% of the teeth. A mesiolingual canal in the mesiobuccal root (MB2 canal) was observed in 54.9% of the images, and the majority (83.5%) of these canals were not filled. Significant associations were observed between the presence of an MB2 canal and the quality of the root canal filling and the presence of AP. Conclusions: AP was detected in more than half of the images. The MB2 canals were frequently missed or poorly filled.