• 제목/요약/키워드: beam measurement

검색결과 1,536건 처리시간 0.031초

Measurement Method and System of Optical Fiber-Based Beam Width Using a Reflective Grating Panel

  • Lee, Yeon-Gwan;Jang, Byeong-Wook;Kim, Yoon-Young;Kim, Jin-Hyuk;Kim, Chun-Gon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권2호
    • /
    • pp.175-178
    • /
    • 2011
  • An optical fiber-based beam width measurement technique is presented. The proposed system can be applied to the optical fiber industry in applications such as lensed fiber, optical fiber based laser beam source, and fiber optic sensor. The measurement system is composed of optical fiber, which is used as a transceiver, and a single grating panel which consists of a multi-reflection area with an even non-reflection area. The grating panel is used to vary the reflected light. When the widths of the reflection area and non-reflection area are larger than the optical beam width, the reflected light is varied at the interface between the reflection area and the non-reflection area by the movement of the grating panel. Experiments were conducted in order to verify the feasibility of the proposed technique. Multi-mode fiber combined with a collimator was selected as an emitter and a receiver, and the beam width measurement system was contrived. Subsequently, the proposed method and the system were verified by comparing the experimental results with the results of the conventional charge-coupled device technique.

레이져를 이용한 진동측정장치 (The Measurement Systme of Vibration using Laser)

  • 진동희;전병철;조종두;김재도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.357-362
    • /
    • 1993
  • In this study low priced laser measurement system was made, so its reliability was investigated Intensity distribution of laser beam measured by devised system and FFT analyzer and their results were examined for proving reliability of devised system. Transmitted laser beam intensity on photodiode changed by eccentrically rotating of disk cam and motor speed. To get results, photodiode and devised amplifier were used for changing voltage. After that, response signal was calculated by signal analysis program. It was found that the vibration of disk cam could be measured by the intensity distribution of laser beam and the same tendency was obtained by FFT. Change of motor speed effected the distribution of laser beam,which was obtained by devised system. Also linear distribution was got by sensitive balancing switch on amplifier according to the transmission of laser beam on photodide.

  • PDF

스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구 (A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.

가우시안 근사를 이용한 6 MeV 전자선의 에너지분포에 관한 연구 (Study on Energy Distribution of the 6 MeV Electron Beam using Gaussian Approximation)

  • 이정옥;김승곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.53-56
    • /
    • 1999
  • A Gaussian distribution was parametrized for the initial distribution of the electron beam emitted from a 6MeV medical linear accelerator. A percent depth dose was measured in a water phantom and the corresponding Monte Carlo calculations were performed starting from a Gaussian distribution for a range of standard deviations, ${\sigma}=0.1$, 0.15, 0.2, 0.25, and 0.3 with being the mean value for the Incident beam energy. When measurement and calculation were compared, the calculation with the Gaussian distribution for ${\sigma}=0.25$ turned out to agree best with the measurement. The results from the present work can be utilized as input energy data in planning an electron beam therapy with a Monte Carlo calculation.

  • PDF

우주전파 수신기를 위한 IF 분배기 및 V/F 컨버터 설계 (DESIGN OF THE IF DISTRIBUTOR AND V/F CONVERTER FOR RECEIVER SYSTEM)

  • 김광동;임인성;변도영;송민규
    • 천문학논총
    • /
    • 제22권3호
    • /
    • pp.83-87
    • /
    • 2007
  • We designed the Intermediate Frequency(IF) distributor for multi beam backend system and manufactured Voltage to Frequency Converter(VFC) to measure the multi-beam receiver performance. Multi beam receiver has 15 channel receivers and can get 15 spectrums at once. The multi beam receiver has more observation efficiency than single beam receiver. We manufactured the 15 IF distributors to distribute IF signal for Autocorrelation spectrometer that is radio signal processor. Also, we manufactured the VF Converter to test the performance measurement of receiver for Korea VLBI Network(KVN) system which is under-construct in Seoul, Ulsan and Jeju. As a result of performance measurement, we could obtain linearity of 99.4% on the input power vs output frequency and measured the operating range of input frequency.

Mevatron KD 선형 가속기에서의 10MV X-선 특성 (Charateristics of 10MV X-ray Beam from a Mevatron KD Linear Accelerator)

  • 이병용;이명자
    • Radiation Oncology Journal
    • /
    • 제6권1호
    • /
    • pp.101-108
    • /
    • 1988
  • The beam characteristics and dosimetric measurements of the 10MV X-ray beam from a Mevatron KD linear accelerator are examined. The Percent Depth Dose (POD) table and the Tissue Maximum Ratio (TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile (including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented.

  • PDF

3차원 레이저 스캐너용 ND 필터의 시뮬레이션 (Simulation of ND Filter for Terrestrial Laser Scanner)

  • 양수효;오동근;정중연
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2009년도 춘계학술발표회 논문집
    • /
    • pp.65-73
    • /
    • 2009
  • The terrestrial laser scanner measures the signal delay time of electronic circuit in EDM(Electronic Distance Measurement) Module for distance measurement. To measure signal delay time precisely, transmitting laser beam of terrestrial laser scanner is divided optically. Therefore, 10% of the laser beam power is entered into the electronic circuit and the others go out through lens. But, measure of delay time is severe in the laser scanner system that the laser beam power is changed dynamically by reflectance of a object, because characters like gain of electronic circuit involving APD(Avalanche Photo Diode) and so on are changed by incident laser beam. Therefore, we adapt ND(Neutral Density) filter that has grid pattern to the laser scanner system to keep constant the incident laser beam power. In this paper, we propose the simulation program for efficient design of ND filter pattern. Finally, to affirm simulation program, we conduct the experimental test of simulated ND filter that has linearly transmittance change, and we consider the experiment result.

  • PDF

가역성 원리를 이용한 반무한보의 진동 인텐시티 측정 (Measurement of Vibration Intensity of a Semi-Infinite Beam Using the Principle of Reciprocity)

  • 양귀봉;길현권;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1073-1077
    • /
    • 2001
  • The objective of this paper is to apply an experimental method based on the principle of reciprocity to measuring the structural intensity. Since only one accelerometer is used in this method it has the advantages of shortening measurement time. reducing accelerometer phase error. overcoming the limitation that the situation should be stationary during the experiment. It has been used to measure the vibration intensity of an infinite beam (beam with damped ends) and a semi-infinite beam (beam with simply supported and damped ends). Results showed that the experiment method based on the principle of reciprocity can be effectively used to measure the structural intensity.

  • PDF

Philips LINAC 6 MV와 8 MV X선 소조사연에 대한 선량분포 측정 (Measurement of Dose Distribution in Small Beams of Philips 6 and 8 MVX Linear Accelerator)

  • 서태석;윤세철;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1991
  • 본 논문에서는 소조사면에 대한 X-선의 선량분포를 일반실험식으로 계산될 수 있도록 beam 측정 데이타를 종합 처리하는 방법에 대하여 기술하고 있다. Beam 데이타는 philips LINAC 6 MV, 8 MV X-ray에 대하여 측정 되었으며, 측정된 요소는 tissue maximum ratio (TMR), off-axis-ratio (OAH), 그리고 relative output factor (ROF)를 포함한다. 소조사면에 의한 방사선 치료를 위하여 isocenter에서 지름이 1 내지 3cm되도록 실린더 형태의 특수 collimator가 2 mm 간격으로 제작되었다. 본 측정을 위하여 다이오드 detector가 이용되었으며 Film 및 TLO 측정기로 측정된 값과 비교검토 되었다. 제한된 조사면으로 측정된 TMR, OAR data로부터 beam 데이타를 나타내는 실험식을 유도하였으며 이 실험식은 임의의 Set-UP조건에 따른 측정값을 예상할 수 있는 일반 실험식으로 확장되었고 측정된 TMR과 OAR 값들은 잘 일치되었다.

  • PDF

전자빔 인출 및 빔 계측과 교육 활용을 위한 기반구축 (The Emission and Characteristics Measurement of Electron Beam and Basis Construction for Education Usage)

  • 이동훈
    • 전기전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.257-264
    • /
    • 2007
  • MM22 마이크로트론은 1986년도 11월부터 2006년 2월까지 암 환자를 위한 방사선 치료 장비로 사용되었다. 장비의 노후로 치료 장비에서 연구 및 교육용으로 전환하기 위해 방사선의학연구센터로 이전 설치하였다. 본 논문에서는 이전 설치 한 후 빔 인출을 수행하기 위해 마이크로트론의 동작원리, 시스템을 구성하는 각 장치의 특성을 분석하여 보았고 주요 부분의 파라메타인 펄스구조의 특징을 살펴보았다. 실제, 각 주요 시스템의 펄스를 측정하였고 빔 인출부, 빔 라인 및 최종단인 타겟에서 빔 인출 기법을 통하여 빔 인출 및 빔 측정을 수행하였다. 이전 설치 후 10 MV X-선의 경우 최종 단 치료기에서 30 mA 타겟 전류를 인출하였고, 필름을 SSD 100 cm, $10{\times}10cm^2$ 조사면에 놓고 100 MU 방사선을 조사하였다. 조사면의 방사선분포의 평탄도 측정 결과 3%이내로 안정적인 빔을 인출하여 이전설치가 성공적으로 수행되었음을 확인할 수 있었다.

  • PDF