본 연구에서는 선형가속기의 소조사면에 보다 정확한 선량계측이 가능하고, 빔 분포 영상화가 가능 계측시스템 개발을 위해 반도체화합물을 이용한 검출 센서를 제작하여 성능평가를 하였다. 센서 제작은 대면적 필름 형성을 위해 입자침전법을 이용하였다. 고에너지 X선에 대한 검출 특성은 암전류, 출력전류, 상승시간, 하강시간, 응답지연 측정을 통해 조사되었다. 측정 결과, $TiO_2$가 혼합된 $HgI_2$ 센서가 $PbI_2$, PbO, $HgI_2$ 보다 우수한 특성을 보였다. 선형가속기를 이용하여 선형성, 재현성 및 정확성 평가를 수행하였으며, 결과적으로 실제 임상에 적용되고 있는 선량 검출기와 감응 특성을 비교 시 재현성, 선형성 및 정확성 등에서 매우 우수한 특성을 나타내는 것을 확인할 수 있었다.
Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.
대구경 배관에서 소구경 배관으로 연결하는 부위 및 배관의 방향 전환을 위해 사용하는 소켓용접부는 용입불량 및 사용시간이 경과되면서 내부로부터 진전될 수 있는 균열 등의 결함을 가질 수 있다. 그러나 지금까지 적용하고 있는 비파괴검사법인 액체침투탐상과 방사선투과검사로는 내부에 존재하는 균열성 결함의 검출이 어렵다. 본 연구에서는 소켓용접부 내부의 균열성 결함 검출을 위한 초음파 검사 기법을 확립하였고, 검사를 수행할 수 있는 초음파 탐촉자를 설계 제작하였으며, 자동으로 검사할 수 있는 검사 장비와 제어용 운영 프로그램을 개발하였다. 개발된 장비는 컴퓨터를 기반으로 하고 있으며, pulser/receiver를 내장하고 100 MHz 고속 A/D board를 사용하여 초음파 탐상기 역할을 프로그램으로 구현하였으며, ISA interface type으로 4축 제어용 motion controller를 개발하여 자동 검사를 수행하는 scanner를 제어하도록 하였으며, 검사 결과는 소켓용접부 단면을 실시간 영상으로 나타내도록 되어 있다. 인공결함 시험편의 결함을 평가한 결과 결함의 깊이가 1mm인 결함의 평가 길이는 실제 크기보다 작게 나타내고 있으며, 결함의 깊이가 증가할수록 결함의 길이가 더 크게 평가되었다. 본 연구로 개발한 장비는 원자력 발전소나 화학플랜트에 많이 널려 있는 소켓용접부 내의 용입불량, 피로 균열 등을 검출하여 객관적인 검사 결과를 제시할 수 있으므로 설비 안전 관리 및 보수 부위 결정에 기여할 수 있을 것으로 기대된다.
안와 림프종의 치료에 가장 효과적인 치료법인 방사선 치료는 안구 질환의 증가로 인해 계속 늘어나는 추세이다. 항암화학요법과 치료 기술의 비약적인 발전으로 치료 및 예후가 좋아지고는 있지만 백내장, 안구건조, 망막병증 등의 부작용이 발생되고 있다. 이에 본 연구에서는 안와 림프종의 방사선치료 시 백내장 발생의 방어수단으로써 Lens Shielding Device(이하 LSD)를 고안 제작하였고 이의 제작방법과 방사선 차폐 정도에 대해 알아보았다. 안구 표면에 해당하는 깊이에서 TLD의 측정결과는 3개의 평균값이 5.7%로 나타났고 관심부위인 수정체의 위치에서는 TLD 4.2%, markus chamber 5.1%의 선량값을 나타내었다. 본 연구에서 안와에 발생한 림프종의 방사선 치료로 인한 부작용을 예방하기 위해 제작한 LSD는 치료 중 조사받게 되는 총 30Gy의 선량 중에서 5%에 해당하는 약 1.5Gy의 방사선량만이 수정체와 각막에 영향을 미치는 것으로 확인되어 백내장의 역치선량인 2Gy와 임상적으로 백내장이 발생된다고 보고된 5Gy보다 적은 선량이 조사됨을 알 수 있었다. 방사선 치료 시 발생할 수 있는 여러 부작용의 예방에 유용한 기구임을 확인하였고 환자의 안구와 일치되도록 개인별로 제작하여 착용 시 이물감에 의한 불편을 줄일 수 있을 뿐만 아니라 치료 시 고정 또한 매우 용이함을 검증하였다.
심장 혈관 협착증 환자의 경우 수술후 재협착을 방지하기 위하여 혈관내 방사선 조사를 실시하여 혈관내벽의 세포증식을 억제하는 방법이 시도되고 있다. 이를 위해 여러 가지 방사성 동위원소가 사용되고 있지만 한국원자력연구소에서 생산되는 Ho-166 도 그 중의 하나의 원소이다. 따라서 이 Ho-166 을 이용하여 혈관내 방사선조사를 할 경우 선량분포를 측정해 보았다. 혈관 내벽을 방사선 조사하는 방법은 풍선 혈관 카테터를 혈관내에 위치시키고 풍선 안에 액체 상태인 Ho-l66 동위원소를 채우고 일정시간 머물게 함으로써 시행된다. 선량분포를 측정하기 위하여 Solid water phantom 과 방사선 흡수선량에 따라 현상기에 현상을 하지 않아도 바로 필름 흑화도 변화를 볼 수 있는 GafChromic Film 을 사용하였다. 필름 흑화도 측정은 Videodensitometer를 이용하였으며 Co-60 빔에 검교정된 GafChromic 필름의 흑화도로 부터 풍선 혈관 카테터 안에 있는 Ho-166 동위원소에 의한 선량분포플 측정하였다. 먼저 Co-60 빔을 이용한 GafChromic Film 의 calibration curve를 얻었다. 흡수선량 대 필름 흑화도 곡선 (H-D curve)은 직선을 이루지 않았으며 이는 densitometer에 쓰이는 광원으로 부터 짐작되는 결과이다. H-D 곡선을 이용하여 Ho-l66이 채워진 풍선 혈관 카테터로 부터의 거리에 따른 선량분포를 얻었으며 카테터 표면으로 부터 1 mm 떨어진 거리에서의 선량은 풍선 표면에서의 약 20% 정도 였으며 5mm 떨어진 거리에서는 풍선 표면 선량의 약 1% 정도로 급속히 떨어짐을 볼 수 있었다. 혈관내 방사선 조사시 중요한 것은 혈관 내 벽에는 원하는 만큼의 방사선량을 주어야 하지만 주변의 정상조직에는 최소한의 손상을 유지해야 하므로 선량분포가 동위원소로 부터 떨어졌을 때 급속히 감소해야 한다는 것이다 따라서 이와같은 이유 때문에 베타선 방출 핵종 들이 많이 시도되고 있으며 동위원소 Ho-l66 도 혈관내벽 방사선조사를 위한 하나의 좋은 핵종으로 이용할 수 있다.
Carbon nanotube (CNT) field effect transistors and sensors use CNT as a current channel, of which the resistance varies with the gate voltage or upon molecule adsorption. Since the performance of CNT devices depends very much on the CNT/metal contact resistance, the CNT/electrode contact must be stable and the contact resistance must be small. Depending on the geometry of CNT/electrode contact, it can be categorized into the end-contact, embedded-contact (top-contact), and side-contact (bottom-contact). Because of difficulties in the sample preparation, the end-contact CNT device is seldom practiced. The embedded-contact in which CNT is embedded inside the electrode is desirable due to its rigidness and the low contact resistance. Fabrication of this structure is complicated, however, because each CNT has to be located under a high-resolution microscope and then the electrode is patterned by electron beam lithography. The side-contact is done by depositing CNT electrophoretically or by precipitating on the patterned electrode. Although this contact is fragile and the contact resistance is relatively high, the side-contact by far has been widely practiced because of its simple fabrication process. Here we introduce a simple method to embed CNT inside the electrode while taking advantage of the bottom-contact process. The idea is to utilize a eutectic material as an electrode, which melts at low temperature so that CNT is not damaged while annealing to melt the electrode to embed CNT. The lowering of CNT/Au contact resistance upon annealing at mild temperature has been reported, but the electrode in these studies did not melt and CNT laid on the surface of electrode even after annealing. In our experiment, we used a eutectic Au/Al film that melts at 250$^{\circ}C$. After depositing CNT on the electrode made of an Au/Al thin film, we annealed the sample at 250$^{\circ}C$ in air to induce eutectic melting. As a result, Au-Al alloy grains formed, under which the CNT was embedded to produce a rigid and low resistance contact. The embedded CNT contact was as strong as to tolerate the ultrasonic agitation for 90 s and the current-voltage measurement indicated that the contact resistance was lowered by a factor of 4. By performing standard fabrication process on this CNT-deposited substrate to add another pair of electrodes bridged by CNT in perpendicular direction, we could fabricate a CNT cross junction. Finally, we could conclude that the eutectic alloy electrode is valid for CNT sensors by examine the detection of Au ion which is spontaneously reduced to CNT surface. The device sustatined strong washing process and maintained its detection ability.
본 연구는 정상 상태의 유동에서 Rayleigh 산란을 이용하여 연료 농도를 측정시 잡음 원인과 대책에 관한 것이다. 실험 장치는 연료 농도 변화를 시간적, 공간적으로 측정함과 동시에 정확한 농도 측정을 위한 보정도 가능하도록 구성하였다. 실험 장치를 우선 보정 용기에 적용하여 프로판, 부탄, 아세틸렌, 프레온 가스의 산란단면적을 구하였다. 이후 내연기관을 상사한 실린더 헤드, 인젝터, 흡기매니폴드, 투명 실린더로 구성된 정상유동 장치를 구성하였다. Rayleigh 산란을 이용한 농도 측정 시 가장 큰 난점은 Mie 산란에 의한 간섭이다. Mie 산란의 영향을 제거하기 위해 하드웨어 필터로 입자의 수 밀도를 측정 가능한 수준으로 감소시켰다. Mie 산란 입자를 충분히 작게 만든 후 광전자 증배관과 앰프의 시정수에 바탕을 둔 소프트웨어 필터를 개발하여 적용하였다. 그리고 바탕 잡음은 광학적 배열을 조정하고 동시에 핀 홀과 빔 트랩을 적용하여 감소시켰다. 실험 결과 LRS는 연료 농도 계측에 매우 유용하게 이용될 수 있고 소프트웨어 필터는 Mie 간섭을 효과적으로 제거할 수 있음을 확인하였다.
Spectral solar irradiances were observed using a visible and UV Multi-Filter Rotating Shadowband Radiometer on the rooftop of the Science Building at Yonsei University, Seoul ($37.57^{\circ}N$, $126.98^{\circ}E$, 86 m) during one year period in 2006. 1-min measurements of global(total) and diffuse solar irradiances over the solar zenith angle (SZA) ranges from $20^{\circ}$ to $70^{\circ}$ were used to examine the effects of clouds and total optical depth (TOD) on enhancing four solar irradiance components (broadband 395-955 nm, UV channel 304.5 nm, visible channel 495.2 nm, and infrared channel 869.2 nm) together with the sky camera images for the assessment of cloud conditions at the time of each measurement. The obtained clear-sky irradiance measurements were used for empirical model of clear-sky irradiance with the cosine of the solar zenith angle (SZA) as an independent variable. These developed models produce continuous estimates of global and diffuse solar irradiances for clear sky. Then, the clear-sky irradiances are used to estimate the effects of clouds and TOD on the enhancement of surface solar irradiance as a difference between the measured and the estimated clear-sky values. It was found that the enhancements occur at TODs less than 1.0 (i.e. transmissivity greater than 37%) when solar disk was not obscured or obscured by optically thin clouds. Although the TOD is less than 1.0, the probability of the occurrence for the enhancements shows 50~65% depending on four different solar radiation components with the low UV irradiance. The cumulus types such as stratoculmus and altoculumus were found to produce localized enhancement of broadband global solar irradiance of up to 36.0% at TOD of 0.43 under overcast skies (cloud cover 90%) when direct solar beam was unobstructed through the broken clouds. However, those same type clouds were found to attenuate up to 80% of the incoming global solar irradiance at TOD of about 7.0. The maximum global UV enhancement was only 3.8% which is much lower than those of other three solar components because of the light scattering efficiency of cloud drops. It was shown that the most of the enhancements occurred under cloud cover from 40 to 90%. The broadband global enhancement greater than 20% occurred for SZAs ranging from 28 to $62^{\circ}$. The broadband diffuse irradiance has been increased up to 467.8% (TOD 0.34) by clouds. In the case of channel 869.0 nm, the maximum diffuse enhancement was 609.5%. Thus, it is required to measure irradiance for various cloud conditions in order to obtain climatological values, to trace the differences among cloud types, and to eventually estimate the influence on solar irradiance by cloud characteristics.
방사선 전신 및 반신 조사방법을 방사선치료에 적용하여 균일한 선량 분포를 유도하고자 조사거리에서 선량측정, 조직결손에 따른 보상과 선량 보정 방법을 논의하였다. 의료용 선형가속기에서 발생된 6MV 광자선을 이용한 전신 조사시의 흡수선량을 결정하는, 선원과 조사면사이의 거리 변화에 따른 계산자료를 조사면의 중심축에서 고체 팬톰, RFA-7 물팬톰(Scanditronix, Sweden)에 대해 UNIDOS 전리함(PTW, Germany), THERADOS 전리함(Scanditronix, Sweden)을 이용한 측정으로 그 크기를 결정하였다. 조직보상체는 연판과 아크릴판을 이용하였다. 전신조사의 조건은 선원으로부터 380 cm의 거리에서 120 $\times$ 120 $cm^2$ ~ 152 $\times$ 152 $cm^2$ 의 조사면을 대상으로 하였다. 전신조사를 위한 기본 자료 측정에서 선원과 조사면의 거리 변화에 따른 흡수 선량 분포는 거리가 멀수록 더 증가하는 현상을 보였고, 조사면의 모서리부분은 약 10-20% 의 선량이 감소되었으나 굴곡좌위형 체위를 취함으로서 선량분포를 보완할 수 있었다. 연판과 아크릴판을 이용한 조직결손에 따른 보상체 제작으로 중심축 선량비를 $\pm$ 8% 이내로 감소시킬 수 있었다. 조직결손의 보상에 따른 선량계산을 고찰하여 임상 적용시 선량분포의 불균일성을 줄일 수 있었다.
최근 UHD, AR, VR 등 초고화질 미디어 데이터 전송에 대한 요구가 증가함에 따라 이를 위한 다양한 기술들이 활발하게 개발되고 있고, 그 중 IEEE 802.11ad 표준의 상용화가 진행 중에 있다. 본 논문에서는 초고주파(mmWave)를 기반으로 근거리 통신을 지원하는 IEEE 802.11ad 표준 기반 모듈을 이용하여 실내 무선 환경을 분석하기 위해 테스트 베드를 구축하고 다양한 실내 무선 환경에 대한 측정 실험 결과를 소개하고 분석한다. 모듈로 데이터 전송을 통해 SNR(Signal to Noise Ratio), Throughput 등의 데이터를 수집하는 방법으로 비교하며, 모듈의 빔 패턴과 폭을 측정하여 복도 및 사무실의 실내 환경에서 미치는 영향을 비교하였다. 이를 통해 벽의 신호 반사로 더 높은 SNR 값을 보여 실외보다 실내에 더 적합하다는 것을 확인하였고, LoS(Line of Sight)가 아닐 때의 손실을 벽면의 반사된 신호가 보완할 만큼 충분하지 않다는 것을 확인하였다. 결론적으로 초고주파 무선랜의 실내 사용에 적합하다고 판단되며 차후 추가적인 실험 구성에 유용하게 활용될 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.