Analysis of dosimetric leaf gap variation on dose rate variation for dynamic IMRT (동적 세기조절방사선 치료 시 선량률 변화에 따른 선량학적엽간격 변화 분석)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • To evaluate the position accuracy of the MLC. This study analyzed the variations of the dosimetric leaf gap(DLG) and MLC transmission factor to reflect the location of the MLC leaves according to the dose rate variation for dynamic IMRT. We used the 6 MV and 10 MV X-ray beams from linear accelerator with a Millennium 120 MLC system. We measured the variation of DLG and MLC transmission factor at depth of 10 cm for the water phantom by varying the dose rate to 200, 300, 400, 500 and 600 MU/min using the CC13 and FC-65G chambers. For 6 MV X-ray beam, a result of measuring based on a dose rate 400 MU/min by varying the dose rate to 200, 300, 400, 500 and 600 MU/min of the difference rate was respectively -2.59, -1.89, 0.00, -0.58, -2.89%. For 10 MV X-ray beam, the difference rate was respectively ?2.52, -1.69, 0.00, +1.28, -1.98%. The difference rate of MLC transmission factor was in the range of about ${\pm}1%$ of the measured values at the two types of energy and all of the dose rates. This study evaluated the variation of DLG and MLC transmission factor for the dose rate variation for dynamic IMRT. The difference of the MLC transmission factor according to the dose rate variation is negligible, but, the difference of the DLG was found to be large. Therefore, when randomly changing the dose rate dynamic IMRT, it may significantly affect the dose delivered to the tumor. Unless you change the dose rate during dynamic IMRT, it is thought that is to be the more accurate radiation therapy.

  • PDF

Changes of lip morphology following mandibular setback surgery using 3D cone-beam computed tomography images

  • Paek, Seung Jae;Yoo, Ji Yong;Lee, Jang Won;Park, Won-Jong;Chee, Young Deok;Choi, Moon Gi;Choi, Eun Joo;Kwon, Kyung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.38.1-38.10
    • /
    • 2016
  • Background: The aims of this study are to evaluate the lip morphology and change of lip commissure after mandibular setback surgery (MSS) for class III patients and analyze association between the amount of mandibular setback and change of lip morphology. Methods: The samples consisted of 14 class III patients treated with MSS using bilateral sagittal split ramus osteotomy. Lateral cephalogram and cone-beam CT were taken before and about 6 months after MSS. Changes in landmarks and variables were measured with 3D software program $Ondemand^{TM}$. Paired and independent t tests were performed for statistical analysis. Results: Landmarks in the mouth corner (cheilion, Ch) moved backward and downward (p < .005, p < .01). However, cheilion width was not statistically significantly changed. Landmark in labrale superius (Ls) was not altered significantly. Upper lip prominence angle (ChRt-Ls-$ChLt^{\circ}$) became acute. Landmarks in stomion (Stm), labrale inferius (Li) moved backward (p < .005, p < .001). Lower lip prominence angle (ChRt-Li-$ChLt^{\circ}$) became obtuse (p < .001). Height of the upper and lower lips was not altered significantly. Length of the upper lip vermilion was increased (p =< 0.01), and length of the lower lip vermilion was decreased (p < .05). Lip area on frontal view was not statistically significantly changed, but the upper lip area on lateral view was increased and change of the lower lip area decreased (p > .05, p < .005). On lateral view, upper lip prominent point (UP) moved downward and stomion moved backward and upward and the angle of Ls-UP-Stm ($^{\circ}$) was decreased. Lower lip prominent point (LP) moved backward and downward, and the angle of Stm-LP-Li ($^{\circ}$) was increased. Li moved backward. Finally, landmarks in the lower incisor tip (L1) moved backward and upward, but stomion moved downward. After surgery, lower incisor tip (L1) was positioned more superiorly than stomion (p < .05). There were significant associations between horizontal soft tissue and corresponding hard tissue. The posterior movement of L1 was related to statistically significantly about backward and downward movement of cheilion. Conclusions: The lip morphology of patients with dento-skeletal class III malocclusion shows a significant improvement after orthognathic surgery. Three-dimensional lip morphology changes in class III patients after MSS exhibited that cheilion moved backward and downward, upper lip projection angle became acute, lower lip projection angle became obtuse, change of upper lip area on lateral view was increased, change of lower lip area decreased, and morphology of lower lip was protruding. L1 was concerned with the lip tissue change in statistically significant way.

Decrease of the Activation and Carbamylation of Rubisco by High CO2 in Kidney Bean (KidneyBean에서의 고 CO2 농도에 의한 Rubisco의 Activation과 Carbamylation의 감소)

  • 노광수;김재기
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.295-302
    • /
    • 1996
  • The measurements of rubisco parameters are important in photosynthetic studies. In this experiment, we used photometric assay method to detect these major parameters, such as activity, carbamylation and amount of rubisco. The main advantages of this method are very simple and as sensitive as conventional methods which usually produce radioactive waste. In this study, with kidney bean (Phaseolus vulgatis L.) leaves grown at normal $CO_2$ (350ppm) and high $CO_2$ (650 ppm), we investigated the effect of $CO_2$ concentration on activation and carbamylation of rubisco by measuring the rubisco activity, carbamylation rate and amount of rubisco using a dual beam (334nm and 405nm) spectrophotometer, and analyzed the polypeptide profiles of rubisco by SDS-PAGE. When $CO_2$ concentration was raised from 350ppm to 650ppm, all parameters of rubisco were decreased : $41.2{\mu}M/m^2/s and 52.2{\mu}M/m^2/s$ to $27.4{\mu}M/m^2/s and 46.1{\mu}M/m^2/s$ for initial and total rubisco activity, respectively ; from 79% to 58.9% for carbamylation rate ; from $1.94 {\mu}M/m^2$ to 1.58{\mu}M/m^2$ for amount of rubisco. These results suggests that the decrease in rubisco activity at high $CO_2$ was caused by carbamylation. The analysis of the preparation by SDS-PAGE showed two major polypeptides at 50 and 14.5 kD which were identified as the large and the small subunits of rubisco. There were no differences in the intensity compared high $CO_2$ to normal $CO_2$ in both 50 kD and 14.5 kD bands. We also found that these inhibitory effects of $CO_2$ were reversible. When high $CO_2$ was switched to normal $CO_2$, the parameters of rubisco changed were almost the same as normal rubisco parameters. These data provide an evidence that activity of rubisco was recovered by $CO_2$ concentration of 350 ppm.

  • PDF

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

High-Dose-Rate Intraluminal Brachytherapy for Biliary Obstruction by Secondary Malignant Biliary Tumors (속발성 담도부 종양에 의한 담도 폐쇄에서 고선량률 관내 근접치료)

  • Yoon Won-Sup;Kim Tae-Hyun;Yang Dae-Sik;Choi Myung-Sun;Kim Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.35-43
    • /
    • 2003
  • Purpose :To analyze the survival period, prognostic factors and complications of patients having undergone high-dose-rate intraluminal brachytherapy (HDR-ILB) as a salvage radiation therapy, while having a catheter, for percutaneous transhepatic billary drainage (PTBD), inserted due to biliary obstruction caused by a secondary malignant biliary tumor Methods and Materials : A retrospective study was performed on 24 patients having undergone HDR-ILB, with PTBD catheter Insertion, be)ween December 1992 and August 2001. Their median age was 58.5, ranging from 35 to 82 years. The primary cancer site were the stomach, gallbladder, liver, pancreas and the colon, with 12, 6, 3, 2 and 1 cases, respectively. Eighteen patients were treated with external beam radiation therapy and HDR-lLB, while slx were treated with HDR-lLB only. The 4otal external beam, and brachytherapy radiations dose were 30$\~$61.2 and 9$\~$30 Gy, with median doses of 50 and 15 Gy, respectively. Results : Of the 24 patients analyzed, 22 died during the follow-up period, with a median survival of 7.3 months. The 6 and 12 months survival rates were 54.2 (13 patients) and 20.8$\%$ (5 patients), respectively. The median survivals for stomach and gailbladder cancers were 7.8 and 10.2 months, respectively, According to the unlvariate analysis, a significant factor affecting survival of over one year was the total radiation dose (over 50 Gy) (o=0.0200), with all )he patients surviving more than one year had been Irradiated with more than 50 Gy. The acute side effects during the radiation therapy were managed with conservative treatment. During the follow-up period, 5 patients showed symptoms of cholangltis due to the radiation therapy Conclusion :An extension to the survival of those patients treated with HDR-ILB is suggested compared to the median historical survival of 4hose patients treated with external biliary drainage. A boost radiation dose could be effectively given, by performing HDR-lLB, which is a prognostic factor In addition, the acute complications of radiation therapy were effectively controlled by conservative management, and It could be regarded as a safe treatment.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters (선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교)

  • Lee Jeong-Woo;Hong Semie;Choi Kyoung-Sik;Chung Jin-Beom;Choe Bo-Young;Jang Hong Seok;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2005
  • For clinical implementation of Enhanced Dynamic Wedge (EDW), it is necessary to adequately analyze and commission its dosimetric properties in comparison to common physical metal wedge (MTW). This study was implemented with the essential measurements of parameters for clinical application, such as percentage depth dose, peripheral dose, surface dose, effective wedge factor, and wedge profile. In addition, through the comparison study of EDW with open and MTW, the analysis was performed to characterize the EDW. We also compared EDW dose profiles of measured values using chamber array 24 (CA24) with calculated values using radiation treatment planning system. PDDs of EDW showed good agreements between $0.2\~0.5\%$ of open beam, but $2\%$ differences with MTW. In the result of the measurements of peripheral dose, it was shown that MTW was about $1\%$ higher than open field and EDW. The surface doses of $60^{\circ}$ MTW showed 10% lower than the others. We found that effective wedge factor of EDW had linear relationships according to Y jaw sizes and was independent of X jaw sizes and was independent of X jaw sizes and asymmetric Y jaw opening. In comparison with measured values and calculate values from Golden-STT based radiation treatment planning system (RTP system), it showed very good agreement within difference of $1\%$. It could be concluded that EDW is a very reliable and useful tool as a beam modification substitute for conventional MTW.

  • PDF

A Comparative Study of Landscape Characteristics on Bridges in Palaces of Korea and China - Focusing on the Chosun Dynasty and Ming and Qing Dynasties - (한국과 중국의 궁궐 내 교량에 관한 경관특성 비교 연구 - 조선시대와 명·청시대를 중심으로 -)

  • Zhang, Fu-Chen;Lee, Ai-Ran
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2019
  • A bridge is a structure constructed on water or in the air for convenient passage. Compared to other buildings, the building materials and structures of bridge required unique functions to cross the space. It depends on the productivity of the building, the level of science and technology, and the ecological environment of the building site. Also, it has important relationship with functions such as politics, military, economy, and life. Most of the academic research on bridges is focused on research in the field of bridge-building technology, so the study on the landscape aesthetics and history of bridges is lacking. Against this backdrop, the study will be valuable as a accumulation of both countries' understanding of bridge types, history and culture, as well as technical and aesthetic data, by analyzing the bridges located within the palaces of Korea and China. The research method is to analyze the bridge through field survey and literature analysis.. First, the bridges of royal palace of Korea and China are to be classified quantitatively as physical shapes, landscapes, and decorations by comparing the materials, forms, landscapes, and decorative culture of bridges. Second, characteristics, common points, and differences are extracted by classifying bridges of both countries. Also, the results are discussed based on the physical environment or cultural background. This would be worth cross-referencing in the building technology and aesthetics of the two countries. For the first important characteristics of result, main materials of Korean and Chinese palaces are stone. However, the bridge in China's royal palaces is also focused on wood. Second, in terms of form, the bridges in the royal gardens of Korea and China are all based on the beam bridge. However, the specific form, ratio, style of the beam bridge, and airspace of arched bridge are very different. Third, most of the connection methods are focused on the over bridge. It values the convergence with the surrounding landscape. Due to the difference in the area and location of water, the bridge in the Korean palace is more focused on the convergence of the surrounding buildings and plants, while the bridge in the Chinese palace is more concerned about the harmony of hydration. Fourth, the decoration places importance on the artistry and aesthetics of both the bridges in Korea and China. There is a difference in style in the same type of decoration due to culture.