• Title/Summary/Keyword: beam analysis

Search Result 6,216, Processing Time 0.04 seconds

THE EFFECT OF ETHYLENE GLYCOL ANALOGS ON MECHANICAL PROPERTIES OF MOIST DEMINERALIZED DENTIN MATRIX (Ethylene Glycol 유사체가 탈회된 상아질의 물리적 성질에 미치는 영향)

  • Lee Kyung-Hee;Cho Young-Gon;Lee Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.290-299
    • /
    • 2006
  • Objectives: The purpose of this study is to evaluate the effect of ethylene glycol analogs on modulus of elasticity and ultimate tensile strength of moist, demineralized dentin matrix. Methods: Dentin disks 0.5 mrn thick were prepared from mid-coronal dentin of extracted. unerupted, human third molars. 'I' beam and hour-glass shaped specimens were prepared from the disks, the ends protected with nail varnish and the central regions completely demineralized in 0.5M EDTA for 5 days. Ultimate tensile stress (UTS) and low strain modulus of elasticity (E) were determined with specimens immersed for 60 min in distilled water $(H_{2}O)$, ethylene glycol $(HO-CH_{2}-CH_{2}-OH)$, 2-methoxyethanol $(H_{3}CO-CH_{2}-CH_{2}-OH)$, and 1,2-dimethoxyethane $(H_{3}CO-CH_{2}-CH_{3}-OCH_{3})$ prior to testing in those same media. Modulus of elasticity was measured on the same specimens in a repeated measures experimental design. The results were analyzed with a one-way ANOVA on ranks, followed by Dunn's test at ${\alpha}\;=\;0.05$. Regression analysis examined the relationship between UTS or E and hoy's solubility parameter for hydrogen bonding $({\delta}_{h})$ of each solvent. Results: The UTS of demineralized dentin in water, ethylene glycol, 2-methoxyethanol, and 1,2-dimethoxyethane was 24 (3), 30 (5), 37 (6), and 45 (6) MPa, ${\times}$ (SD) N = 10. Low strain E for the same media were 16 (13), 23 (14), 52 (24), and 62 (22) MPa. Regression analysis of UTS vs ${\delta}_{h}$ revealed a significant $(p\;<\;0.0001,\;r\;=\;-0.99,\;R^{2}\;=\;0.98)$ inverse, exponential relationship. A similar inverse relationship was obtained between low strain E vs ${\delta}_{h}\;(p\;<\;0.0005,\;r\;=\;-0.93,\;R^{2}\;=\;0.86)$. Significance: The tensile properties of demineralized dentin are dependent upon the hydrogen bonding ability of polar solvents $({\delta}_{h})$. Solvents with low ${\delta}_{h}$ values may permit new interpeptide H-bonding in collagen that increases its tensile properties. Solvents with high ${\delta}_{h}$ values prevent the development of these new interpeptide H-bonds.

Selective Oxidation of Single Crystalline AlAs layer on GaAs substrate and XPS(X-ray photoelectron spectroscopy) Analysis (GaAs 기판위에 성장된 단결정 AlAs층의 선택적 산화 및 XPS (X-ray photonelectron spectroscopy) 분석)

  • Lee, Suk-Hun;Lee, Young-Soo;Tae, Heung-Sik;Lee, Young-Hyun;Lee, Jung-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.79-84
    • /
    • 1996
  • A $1\;{\mu}m$ thick n-type GaAs layer with Si doping density of $1{\times}10^{17}/cm^{3}$ and a $500{\AA}$ thick undoped single crystalline AlAs layer were subsequently grown by molecular beam epitaxy on the $n^{+}$ GaAs substrate. The AlAs/GaAs layer was oxidized in $N_{2}$ bubbled $H_{2}O$ vapor($95^{\circ}C$) ambient at $400^{\circ}C$ for 2 and 3 hours. From the result of XPS analysis, small amounts of $As_{2}O_{3}$, AlAs, and elemental As were found in the samples oxidized up to 2 hours. After 3 hours oxidation, however, various oxides related to As were dissolved and As atoms were diffused out toward the oxide surface. The as-grown AlAs/GaAs layer was selectively converted to $Al_{2}O_{3}/GaAs$ at the oxidation temperature $400^{\circ}C$ for 3 hours. The oxidation temperature and time is very critical to stop the oxidation at the AlAs/GaAs interface and to form a defect-free surface layer.

  • PDF

Evaluation of Deformation Characteristics and Vulnerable Parts according to Loading on Compound Behavior Connector (복합거동연결체의 하중재하에 따른 변형 특성 및 취약부위 산정)

  • Kim, Ki-Sung;Kim, Dong-wook;Ahn, Jun-hyuk
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.524-530
    • /
    • 2019
  • Purpose: In this paper, we construct a detailed three-dimensional interface element using a three-dimensional analysis program, and evaluate the composite behavior stability of the connector by applying physical properties such as the characteristics of general members and those of reinforced members Method: The analytical model uses solid elements, including non-linear material behavior, to complete the modeling of beam structures, circular flanges, bolting systems, etc. to the same dimensions as the design drawing, with each member assembled into one composite behavior linkage. In order to more effectively control the uniformity and mesh generation of other element type contact surfaces, the partitioning was performed. Modeled with 50 carbon steel materials. Results: It shows the displacement, deformation, and stress state of each load stage by the contact adjoining part, load loading part, fixed end part, and vulnerable anticipated part by member, and after displacement, deformation, The effect of the stress distribution was verified and the validity of the design was verified. Conclusion: Therefore, if the design support of the micro pile is determined based on this result, it is possible to identify the Vulnerable Parts of the composite behavior connector and the degree of reinforcement.

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF

Study on Growth Optimization of InAs/GaSb Strained-Layer Superlattice Structures by High-Resolution XRD Analysis (고분해능 XRD 분석에 의한 InAs/GaSb 응력초격자 구조의 성장 최적화 연구)

  • Kim, J.O.;Shin, H.W.;Choe, J.W.;Lee, S.J.;Kim, C.S.;Noh, S.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.245-253
    • /
    • 2009
  • For the growth optimization of InAs/GaSb (8/8-ML) strained-layer superlattice (SLS), the structure has been grown under various conditions and modes and characterized by the high-resolution x-ray diffraction (XRD) analysis. In this study, the strain modulation is induced by changing parameters and modes, such as the growth temperature, the ratio of V/III beam-equivalent-pressure (BEP), and the growth interruption (GI), and the strain variation is analyzed by measuring the angle separation of 0th-order satellite peak in XRD patterns. The XRD results reveal that the growth temperature and the V/III(Sb/Ga) ratio are major parameters to change the crystallineity and the strain modulation in SLS structures, respectively. We have observed that the SLS samples with compressive strain prepared in this study are show a transition to tensile strain with decreasing V/III(Sb/Ga) ratio, and the GI process is a sensitive factor giving rise to strain modulation. These results obtained in this study suggest that optimized growth temperature and V/III(Sb/Ga) ratio are $350^{\circ}C$ and 20, respectively, and the appropriate GI time is approximately 3 seconds just before InAs growth that the crystallineity is maximized and the strain relaxation is minimized.

Enhancement of SNUF Active Trailing-edge Flap Blade Mechanism Design (SNUF뒷전 플랩 블레이드 메커니즘의 설계 개선)

  • Natarajan, Balakumaran;Eun, WonJong;Shin, SangJoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.7
    • /
    • pp.645-653
    • /
    • 2013
  • Seoul National University flap(SNUF) blade is a small-scale rotor blade incorporating a small trailing-edge flap control surface driven by piezoelectric actuators at higher harmonics for vibration attenuation. Initially, the blade was designed using two-dimensional cross-section analysis and geometrically exact one-dimensional beam analysis, and its material configuration was finalized. A flap-deflection angle of ${\pm}4^{\circ}$ was established as the criterion for enhanced vibration reduction based on an earlier simulation. The flap-linkage mechanism was designed and static bench tests were conducted for verifying the performance of the flap-actuation mechanism. Different versions of test beds were developed and tested with the designed flap and the selected APA 200M piezoelectric actuators. Through significant improvements, a maximum deflection of ${\pm}3.7^{\circ}$ was achieved. High-frequency experiments were conducted for evaluating the performance, and the transfer function of the test bed was determined experimentally. With the static tests almost complete, the rotor power required for testing the blade in a whirl tower (centrifugal environment) was calculated, and further preparations are underway.

The Role of Surgical Resection in the Treatment of Newly-Diagnosed Supratentorial Lobar Glioblastoma in Adults (성인에서 천막상부, 두개엽에 위치한 원발성 교모세포종의 치료에서 종양 절제의 역할)

  • Rhee, Jong Joo;Ahn, Jae Sung;Jeon, Sang Ryong;Kim, Jeong Hoon;Ra, Young Shin;Kim, Chang Jin;Lee, Jung Kyo;Kwun, Byung Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.221-227
    • /
    • 2001
  • Objective : The therapeutic impact of tumor resection in glioblastomas is poorly defined and still questionable. Therefore, we conducted the current study to verify the role of tumor resection in the treatment of these highly malignant tumors. Methods : A retrospective study was performed(1990-1999) to compare the treatment results of surgical resection plus radiotherapy(130 patients) with those of stereotactic biopsy plus radiotherapy(19 patients) in glioblastomas. Only adult patients with supratentorial, de novo glioblastoma located in one lobe were included. Survival time/rate was analysed with Kaplan-Meier method, and prognostic variables were obtained from the univariate log-rank test and the multivariate Cox's proportional hazards model. Results : The resection group and the biopsy group did not differ in terms of age, gender, duration of symptoms, presenting symptoms, tumor location, tumor side, tumor size, and the frequency of midline shift. Patients in the biopsy group more often were found to have worse preoperative Karnofsky performance status(KPS)(p=0.001). On univariate analysis, age, KPS, and tumor side were associated with survival(p=0.0053, 0.0001, and 0.0331 respectively). Median survival time and 1-year survival rate were also statistically improved by tumor resection ; resection group - 13 months and 61.2%, and biopsy group - 8 months and 19.7%, respectively(p=0.0001). In patients with midline shift of the tumor, resection was highly effective comparing to biopsy(p=0.0001), but in patients without midline shift, external beam radiation alone was as effective as tumor resection(p=0.0605). Other prognostic variables did not affect survival. On multivariate analysis after variable selection, survival was independently associated with KPS(p=0.001), but not the surgical resection(p=0.2837). Even in biopsy group with midline shift of the tumor, survival rate was not different from that seen after tumor resection(p=0.3505). Conclusions : Radiotherapy alone was as effective as tumor resection plus radiotherapy in patients without midline shift of the tumor. Although there was not statistically significant, tumor resection looked like effective in patients with midline shift. For supratentorial, lobar glioblastoma patients without mass effect of the tumor, biopsy with radiotherapy is one of rational treatment strategies. We consider that tumor resection should be performed in patients with pretreatment midline shift.

  • PDF

The improvement of electrical properties of InGaZnO (IGZO)4(IGZO) TFT by treating post-annealing process in different temperatures.

  • Kim, Soon-Jae;Lee, Hoo-Jeong;Yoo, Hee-Jun;Park, Gum-Hee;Kim, Tae-Wook;Roh, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.169-169
    • /
    • 2010
  • As display industry requires various applications for future display technology, which can guarantees high level of flexibility and transparency on display panel, oxide semiconductor materials are regarded as one of the best candidates. $InGaZnO_4$(IGZO) has gathered much attention as a post-transition metal oxide used in active layer in thin-film transistor. Due to its high mobility fabricated at low temperature fabrication process, which is proper for application to display backplanes and use in flexible and/or transparent electronics. Electrical performance of amorphous oxide semiconductors depends on the resistance of the interface between source/drain metal contact and active layer. It is also affected by sheet resistance on IGZO thin film. Controlling contact/sheet resistance has been a hot issue for improving electrical properties of AOS(Amorphous oxide semiconductor). To overcome this problem, post-annealing has been introduced. In other words, through post-annealing process, saturation mobility, on/off ratio, drain current of the device all increase. In this research, we studied on the relation between device's resistance and post-annealing temperature. So far as many post-annealing effects have been reported, this research especially analyzed the change of electrical properties by increasing post-annealing temperature. We fabricated 6 main samples. After a-IGZO deposition, Samples were post-annealed in 5 different temperatures; as-deposited, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$ and $500^{\circ}C$. Metal deposition was done on these samples by using Mo through E-beam evaporation. For analysis, three analysis methods were used; IV-characteristics by probe station, surface roughness by AFM, metal oxidation by FE-SEM. Experimental results say that contact resistance increased because of the metal oxidation on metal contact and rough surface of a-IGZO layer. we can suggest some of the possible solutions to overcome resistance effect for the improvement of TFT electrical performances.

  • PDF

In-Plane Extensional Vibration Analysis of Asymmetric Curved Beams with Linearly Varying Cross-Section Using DQM (미분구적법(DQM)을 이용한 단면적이 선형적으로 변하는 비대칭 곡선보의 내평면 신장 진동해석)

  • Kang, Ki-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.612-620
    • /
    • 2019
  • The increasing use of curved beams in buildings, vehicles, ships, and aircraft has results in considerable effort being directed toward developing an accurate method for analyzing the dynamic behavior of such structures. The stability behavior of elastic curved beams has been the subject of a large number of investigations. Solutions of the relevant differential equations have traditionally been obtained by the standard finite difference. These techniques require a great deal of computer time as the number of discrete nodes becomes relatively large under conditions of complex geometry and loading. One of the efficient procedures for the solution of partial differential equations is the method of differential quadrature. The differential quadrature method(DQM) has been applied to a large number of cases to overcome the difficulties of the complex algorithms of programming for the computer, as well as excessive use of storage due to conditions of complex geometry and loading. In this study, the in-plane extensional vibration for asymmetric curved beams with linearly varying cross-section is analyzed using the DQM. Fundamental frequency parameters are calculated for the member with various parameter ratios, boundary conditions, and opening angles. The results are compared with the result by other methods for cases in which they are available. According to the analysis of the solutions, the DQM, used only a limited number of grid points, gives results which agree very well with the exact ones.

Development of Permit Vehicle Classification System for Bridge Evaluation in Korea (허가차량 통행에 대한 교량의 안전성 평가를 위한 허가차량 분류 체계 개발)

  • Yu, Sang Seon;Kim, Kyunghyun;Paik, Inyeol;Kim, Ji Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.845-856
    • /
    • 2020
  • This study proposes a bridge evaluation system for indivisible permit vehicles such as hydraulic cranes. The permit loads for the bridge evaluation are divided into three categories: routine permit loads, special permit 1 loads, and special permit 2 loads. Routine permit and special permit 1 vehicles are allowed to cross a bridge with normal traffic. For these two permits, the standard lane model in the Korean Highway Bridge Design Code was adopted to consider normal traffic in the same lane. Special permit 2 vehicles are assumed to cross a bridge without other traffic. Structural analyses of two prestressed-beam bridges and two steel box girder bridges were conducted for the proposed permit loads. The rating factors of the four bridges for all permit loads were calculated as sufficiently large values for the moment and shear force so that crossing the bridges can be permitted. A reliability assessment of the bridges was performed to identify the reliability levels for the permit vehicles. It was confirmed that the reliability level of the minimum required strength obtained by the load-resistance factors yields the target reliability index of the design code for the permit vehicles.