• 제목/요약/키워드: beam alignment

검색결과 257건 처리시간 0.027초

PDMS기판에 이온빔 처리에 따른 수평 액정의 배향 연구

  • 김영환;오병윤;김병용;이원규;임지훈;나현재;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.159-159
    • /
    • 2009
  • We characterize a flexible self-assembled liquid crystal display (LCD) fabricated from a polyimide (PI) alignment layer with polydimethylsiloxane pixel walls. Ion beam (IB) irradiation aligned LC molecules in the PI layer and bonded two flexible plastic substrates in a one-step assembly of the pixel walls. X-ray photoelectron spectroscopic analysis, Fourier transform infrared spectroscopy, and scanning electron microscopy provided chemical and physical evidence for the formation of stable chemical bonds between the PI layer and the PDMS pixel walls in addition to the important maintenance of a uniform 6 um gap between the two substrates without the use of any epoxy resins or other polymers.

  • PDF

조사연료봉 봉단마개의 레이저용접기술 (Technology of the End Cap Laser Welding for Irradiation Fuel Rods)

  • 김수성;이정원;고진현;이영호
    • Journal of Welding and Joining
    • /
    • 제21권6호
    • /
    • pp.20-25
    • /
    • 2003
  • Various welding methods such as Gas Tungsten Arc Welding(GTAW), magnetic force electrical resistance welding and Laser Beam Welding(LBW) are now available for end cap closure of nuclear fuel rods. Even though the resistance and GTA welding processes are widely used in manufacturing commercial fuel rods, they can not be recommended for the remote seal welding of fuel rods in the hot cell Facility due to the complexity of the electrode alignment, the difficulty in replacing parts in a remote manner and the large heat input for the thin sheath. Therefore, the Nd:YAG laser system using optical fiber transmission was selected for the end cap welding of irradiation fuel rods in the hot cell. The remote laser welding apparatus in the hot cell Facility was developed using a pulsed Nd:YAG laser of 500 watt average power with an optical fiber transmission. The weldment quality such as microstructure and mechanical strength was satisfactory. The optimum conditions of laser welding for encapsulating irradiation fuel rods in the hot cell were obtained.

New stability equation for columns in unbraced frames

  • Essa, Hesham S.
    • Structural Engineering and Mechanics
    • /
    • 제6권4호
    • /
    • pp.411-425
    • /
    • 1998
  • The effective length factor of a framed column may be determined by means of the alignment chart procedure. This method is based on many unrealistic assumptions, among which is that all columns have the same stiffness parameter, which is dependent on the length, axial load, and moment of inertia of the column. A new approximate method is developed for the determination of effective length factors for columns in unbraced frames. This method takes into account the effects of inelastic column behaviour, far end conditions of the restraining beams and columns, semi-rigid beam-to-column connections, and differentiated stiffness parameters of columns. This method may be implemented on a microcomputer. A numerical study was carried out to demonstrate the extent to which the involved parameters affect the K factor. The beam-to-column connection stiffness, the stiffness parameter of columns, and the far end conditions of restraining members have a significant effect on the K factor of the column under investigation. The developed method is recommended for design purposes.

Analysis of CRUD Flake Applied to Abnormal High Beam Current by Shielded-EPMA

  • Jung, Y.H.;Baik, S.J.;Ahn, S.B.
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.265-271
    • /
    • 2018
  • CRUD specimens, scraped from twice-burned fuel cladding in the Korean Nuclear Power Plant, were analyzed using Shielded-EPMA. The principal elements of the CRUD were identified as Ni and Fe, at an approximate ratio of 1.3 Ni/Fe. To investigate the morphology and composition of the pure metallic materials in the CRUD, coolant impurities must be removed. This can be accomplished by increasing the EPMA current to an abnormally high intensity until the impurities are melted. Normally, EPMA applications are performed at conditions of 20 kV voltage and 20 nA current. But in our study, the applied current was increased up to 1200 nA, over time increments ranging from 5 to 30 seconds. This technique was performed by opening an adjustable aperture for the gun alignment. Results showed impurities contained in the CRUD material disappeared and pure metal materials, e.g., Ni and Fe, remained. This method presents an innovative way to analyze CRUD.

U-플랜지 트러스 보의 구조 내력에 관한 실험 연구 (Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam)

  • 오명호;김영호;강재윤;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.113-121
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.

Boron Nitride Films Grown by Low Energy Ion Beam Assisted Deposition

  • Park, Young-Joon;Baik, Young-Joon;Lee, Jeong-Yong
    • The Korean Journal of Ceramics
    • /
    • 제6권2호
    • /
    • pp.129-133
    • /
    • 2000
  • Boron nitride films were synthesized with $N_2$ion flux of low energy, up to 100 eV, at different substrate temperatures of no heating, 200, 400, 500, and $800^{\circ}C$, respectively. Boron was supplied by e-beam evaporation at the rate of $1.5\AA$/sec. For all the conditions, hexagonal BN (h-BN) phase was mainly synthesized and high resolution transmission electron microscopy (HRTEM) showed that (002) planes of h-BN phase were aligned vertical to the Si substrate. The maximum alignment occurred around $400^{\circ}C$. In addition to major h-BN phase, transmission electron diffraction (TED) rings identified the formation of cubic BN (c-BN) phase. But HRTEM showed no distinct and continuous c-BN layer. These results suggest that c-BN phase may form in a scattered form even when h-BN phase is mainly synthesized under small momentum transfer by bombarding ions, which are not reconciled with the macro compressive stress model for the c-BN formation.

  • PDF

Electro-optical Characteristics of the One-side Rubbing TN-LCD on Polyimide Surface with Ion-beam Irradiation

  • Kim, Young-Hwan;Lee, Kang-Min;Kim, Byoung-Yong;Oh, Byeong-Yun;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.198-201
    • /
    • 2008
  • The electro-optical (EO) characteristics of the one-side rubbing twisted nematic (TN) - liquid crystal display (LCD) on the polyimide (PI) surface with one-side ion beam (IB) irradiation were successfully studied. The good LC alignment for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation was observed. The suitable transmittance-voltage curves for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation were measured. Also, the good response time characteristics of the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation were measured. The fast response time can be achieved for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation.

Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Byoung-Jun;Park, Deok-Woo;Jung, Byoung-Hoon;Lee, Hyo-Jin;Hong, Ji-Young;Kim, Seung-Chul
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

  • PDF

Femtosecond laser induced photo-expansion of organic thin films

  • 채상민;이명수;최지연;이현휘;김효정
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.120.2-120.2
    • /
    • 2015
  • We propose a novel direct writing technique with a femtosecond laser enabling selective modification of not only the morphology of conducting polymer thin films but also the orientation and alignment of the polymer crystal. Surface relief gratings resulting from photoexpansion on P3HT:PCBM and PEDOT:PSS thin films were fabricated by femtosecond laser direct writing. The photoexpansion was induced at laser fluence below the ablation threshold of the thin film. The morphology (size and shape) of photoexpansion could be quantitatively controlled by laser writing parameters such as focused beam size, writing speed, and laser fluence. GIWAX results showed that face-on P3HT crystals were largely increased in the photoexpansion in comparison with pristine region of the thin film. In addition, the face-on P3HTs in the photoexpansion were aligned with their orientation along the polarization of the laser. The micro-RAMAN spectra confirmed that neither chemical composition change nor the polymer chain breaking was observable after femtosecond laser irradiation. We believe that this laser direct writing technique opens a new door to the fabrication of more efficient OPVs via non-contact, toxic-free approach.

  • PDF

Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

  • Park, Yang-Soon;Han, Sun-Ho;Kim, Jong-Goo;Jee, Kwang-Yong;Kim, Won-Ho
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.407-414
    • /
    • 2006
  • An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-XRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at $5{\mu}m$ steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was $4,000{\times}20{\mu}m$ and the spatial resolution of the beam was $47{\mu}m$ at the sample position. When the diffraction peaks were measured for a $UO_2$ pellet specimen by this system, the reproducibility ($2{\Theta}={\pm}0.01^{\circ}$) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only $TiO_2$ in an outer layer but also TiO near an oxide-metal interface was observed.