• 제목/요약/키워드: beagle dogs.

검색결과 358건 처리시간 0.029초

Integrative Analysis of Probiotic-Mediated Remodeling in Canine Gut Microbiota and Metabolites Using a Fermenter for an Intestinal Microbiota Model

  • Anna Kang;Min-Jin Kwak;Hye Jin Choi;Seon-hui Son;Sei-hyun Lim;Ju Young Eor;Minho Song;Min Kyu Kim;Jong Nam Kim;Jungwoo Yang;Minjee Lee;Minkyoung Kang;Sangnam Oh;Younghoon Kim
    • 한국축산식품학회지
    • /
    • 제44권5호
    • /
    • pp.1080-1095
    • /
    • 2024
  • In contemporary society, the increasing number of pet-owning households has significantly heightened interest in companion animal health, expanding the probiotics market aimed at enhancing pet well-being. Consequently, research into the gut microbiota of companion animals has gained momentum, however, ethical and societal challenges associated with experiments on intelligent and pain-sensitive animals necessitate alternative research methodologies to reduce reliance on live animal testing. To address this need, the Fermenter for Intestinal Microbiota Model (FIMM) is being investigated as an in vitro tool designed to replicate gastrointestinal conditions of living animals, offering a means to study gut microbiota while minimizing animal experimentation. The FIMM system explored interactions between intestinal microbiota and probiotics within a simulated gut environment. Two strains of commercial probiotic bacteria, Enterococcus faecium IDCC 2102 and Bifidobacterium lactis IDCC 4301, along with a newly isolated strain from domestic dogs, Lactobacillus acidophilus SLAM AK001, were introduced into the FIMM system with gut microbiota from a beagle model. Findings highlight the system's capacity to mirror and modulate the gut environment, evidenced by an increase in beneficial bacteria like Lactobacillus and Faecalibacterium and a decrease in the pathogen Clostridium. The study also verified the system's ability to facilitate accurate interactions between probiotics and commensal bacteria, demonstrated by the production of short-chain fatty acids and bacterial metabolites, including amino acids and gamma-aminobutyric acid precursors. Thus, the results advocate for FIMM as an in vitro system that authentically simulates the intestinal environment, presenting a viable alternative for examining gut microbiota and metabolites in companion animals.

성견에서 표면처리된 교정용 마미크로 임플랜트의 골 접촉률 및 동요도 (Bone-implant contact and mobility of surface-fronted orthodontic micro-implants in dogs)

  • 박승현;김성훈;류준하;강윤구;정규림;국윤아
    • 대한치과교정학회지
    • /
    • 제38권6호
    • /
    • pp.416-426
    • /
    • 2008
  • 본 연구는 비글견에 식립된 sandblasted, large grit and acid-etched (SLA) 표면처리된 교정용 마이크로임플랜트와 평활면 마이크로임플랜트에 교정력을 가한 후 시간 경과에 따른 동요도와 골접촉률의 차이를 규명하기 위해 시행되었다. 비글 성견 네 마리를 이용하여 상, 하악 협측과 구개측 골에 대해 SLA 표면처리된 표면처리군 48개, 평활면의 비처리군 48개의 마이크로임 플랜트 96개를 식립하고 2주의 치유기간 후 교정력(150 - 200 g)을 지속적 으로 가했으며 식립 4주 후에 두 마리를 희생시키고, 12주 후에 나머지 2마리를 희생시켰다. 표면처리군과 비처리군 간의 마이크로 임플랜트의 동요도와 골과 임플랜트 간 접촉률을 조직학적인 측면에서 측정 비교하여 다음과 같은 결과를 얻었다. 상악 협측과 구개측에서는 표면처리군과 미처리군의 동요도에서 유의성 있는 차이가 없었으나 하악협측에서는 표면 처리군이 유의하게 안정적인 동요도를 보였다. 마이크로임플랜트와 인접골 간 접촉률은 상악 협측에서는 4주와 12주 모두 표면처리군과 미처리군 간에 유의 한 차이가 없었으나 하악 협측과 구개측의 경우 4주와 12주 모두 표면처리군이 비처리군에 비해 유의하게 높은 접촉률을 보였다. 표면처리군은 비처리군에 비해 임플랜트 주변에서 활발한 골개조가 관찰되었으며 모든 군에서 이물반응은 관찰되지 않았다. 본 연구를 통해 SLA 표면처리된 마이크로임플랜트는 평활면 마이크로임플랜트에 비하여 식립 초기에는 식립 부위에 따라 유의하게 높은 인접골 간 접촉률과 동요도의 안정성을 보임으로써 다양한 크기와 방향의 교정력의 적용이 가능할 것이라 생각한다.

교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구 (The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant)

  • 정규림;이성자
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.173-185
    • /
    • 2001
  • 본 연구는 경희대학교 치과대학 교정과와 Biosstech$^{\circledR)$이 개발한 교정용 골유착성 티타니움 임프란트를 이용하여 임프란트 매식 후 가해지는 교정력이 임프란트의 골유착에 미치는 영향과 임프란트 제거 후 손상된 치조골의 치유를 알아보기 위해 시행되었다. acid-etched type, sand-blasted type, sand-blasted & acid-etched type, 3종류의 교정용 임프란트 24개를 2마리 실험 동물의 구강 내에 식립하였다. dog1의 상하악 좌측에 식립한 6개 임프란트에는 식립 후 교정력을 주지 않았고, 우측에 식립한 6개 임프란트에는 식립 즉시 200-300gm의 교정력을 가하였다. dog2에서는 임프란트 식립후 4주의 치유기간을 기다린 후, 골 내에 고정되어 있는 모든 임프란트에 4주 동안 200-300gm의 교정력을 가하였다. 4주, 8주의 관찰 기간이 지난 후 실험 동물을 각각 희생시켜 임프란트와 주위 조직을 포함하는 비탈회 표본을 제작하여 광학 현미경하에서 검경하였다. 이 실험을 통해 다음과 같은 결과를 얻었다. 1. 골내 고정에 성공한 임프란트들의 식립 4주 후 조직 소견에서, 식립 즉시 교정력을 가한 임프란트와 교정력을 가하지 않은 임프란트 사이에 조직학적 차이가 없었다. 두 군 모두에서 미성숙 소주골이 임프란트 식립시 손상된 부위로 생성되고 있었으며 부분적인 골유착이 보였다. 2. 임프란트 식립 부위의 골손상이 완전히 치유되기 전에 가해진 교정력은 골유착의 진행을 방해하지 않았다. 4주의 치유기간 후 4주간 교정력을 가한 임프란트의 조직소견에서 골조직과 임프란트 계면 사이의 접촉은 더 넓은 부위로 진행되었고 나사골을 채우고 있는 신생골은 기저골의 구조와 형태를 닮은 층판골로 성숙되어 있었다. 3. 식립 후 임프란트 주위 연조직 염증이 심했던 임프란트는 대부분 탈락되거나 동요가 있었으며, 실험 동물 희생시 동요가 있었던 임프란트의 조직 소견에서 임프란트 주위는 연조직으로 둘러 쌓여 골조직과 분리되어 있었다. 4. 골내 고정에 실패한 임프란트의 식립 부위에서는 임프란트 제거 2주 후 염증 소견없이 왕성한 골형성을 나타내는 조직학적 소견이 관찰되었다.

  • PDF

성견에 식립된 sandblasted and large-grit and acid-etched 임플란트에서 N-acetyl cysteine(NAC)의 탑재가 주위 골형성에 미치는 영향에 대한 선행연구 (The Effect of N-acetyl cysteine (NAC) loading on the bone formation surrounding sandblasted and large-grit and acid-etched implants in the dog: A pilot study)

  • 서재민;김인주;배민수;이정진;안승근
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.77-85
    • /
    • 2020
  • 목적: N-acetyl cysteine (NAC)를 탑재한 sandblasted and large-grit and acid-etched (SLA) 임플란트를 성견에 식립한 후, 조직형태학적 분석을 통하여 NAC가 SLA 임플란트 주위의 초기 골형성에 미치는 영향을 알아보고자 한다. 재료 및 방법: NAC 탑재 여부에 따라 2개의 실험군으로 구성하였으며, SI 군은 NAC를 탑재하지 않은 SLA 임플란트로, NSI 군은 NAC를 탑재한 SLA 임플란트로 설정하였다. 4마리의 성체 비글 견에 두 실험군의 임플란트를 식립하고(각 군당 n = 8) 술 후 3주와 6주에 각각 2마리의 비글 견을 희생하여 식립된 임플란트 매식체와 주위 골 조직을 채취하였다. 조직 표본을 제작하고 조직형태학적 검사를 통해 골-임플란트 접촉률 및 골면적비율을 계산하였다. NAC 탑재 여부에 따른 각 실험군간 골-임플란트 접촉률과 골면적비율의 유의성을 알아보기 위해 독립표본 t검정을 이용한 통계분석을 시행하였다(α = .05). 결과: 3주차의 경우 NAC를 탑재한 SLA 임플란트가 일반 SLA 임플란트보다 약 1.5배 높은 골-임플란트 접촉률을 보였으나 통계적 유의성은 없었다(51.79 vs 35.43%; P = .185). 골면적 비율에서는 NAC를 탑재한 SLA 임플란트가 일반 SLA 임플란트보다 통계적으로 유의성 있게 높은 결과 값을 보였다(45.09 vs 37.57 %; P = .044). 6주차의 경우 골-임플란트 접촉률과 골면적 비율 모두에서 NAC를 탑재한 SLA 임플란트와 일반 SLA 임플란트가 비슷한 결과 값을 보였다(P > .05). 결론: 본 실험의 한계 내에서 NAC는 SLA 임플란트 주위의 초기 골형성에 긍정적인 영향을 미침으로써 임플란트의 골유착기간을 단축시키고 하중 부담시기를 앞당기는 데에 기여할 것이라고 사료된다.

배양골세포 이식이 치조골재생에 미치는 영향 (Effects Of Cultured Bone Cell On The Regeneration Of Alveolar Bone)

  • 정순준;허익;박준봉;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.1-26
    • /
    • 1996
  • This study was performed to estimate the effects of cultured bone cell inoculated on porous type hydroxyaptite for the regeneration of the artificial alveolar bone defect. In this experiment 3 beagle dogs were used, and each of them were divided into right and left mandible. Every surgical intervention were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). To reduce the gingival bleeding during surgery, operative site was injected with Lidocaine hydrochloride(l:80,000 Epinephrine) as local anesthesia. After surgery experimental animal were feeded with soft dietl Mighty dog, Frisies Co., U.S.A.) for 1 weeks to avoid irritaion to soft tissue by food. 2 months before surgery both side of mandibular 1st premolar were extracted and bone chips from mandibular body were obtained from all animals. Bone cells were cultured from bone chips obtained from mandible with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. Porous type hydroxyapatite were immerse into the high concentrated cell suspension solution, and put 4 hours for attachin the cells on the surface of hydroxyapatite. Graft material were inserted on the artificial bone defect after 3 days of culture. Before insertion of cellinoculated graft material, scanning electronic microscopic observation were performed to confirm the attachment and spreading of cell on the hydroxyapatite surface. 3 artificial bone defects were made with bone trephine drill on the both side of mandible of the experimental animal. First defect was designed without insertion of graft material as negative control, second was filled with porous replamineform hydroxyapatite inoculated with cultured bone marrow cells as expermiental site, and third was filled with graft materials only as positive control. The size of every artificial bone defect was 3mm in diameter and 3mm in depth. After the every surgical intervention of animals, oral hygiene program were performed with 1.0% chlorhexidine digluconate. All of the animals were sacrificed at 2, 4, 6 weeks after surgery. For obtaining histological section, tissus were fixed in 10% Buffered formalin and decalcified with Planko - Rycho Solution for 72hr. Tissue embeding was performed in paraffin and cut parallel to the surface of mandibular body. Section in 8um thickness of tissue was done and stained with Hematoxylin - Eosin. All the specimens were observed under the light microscopy. The following results were obtained : 1. In the case of control site which has no graft material, less inflammatory cell infiltration and rapid new bone forming tendency were revealed compared with experimental groups. But bone surface were observed depression pattern on defect area because of soft tissue invasion into the artificial bone defect during the experimental period. 2. In the porous hydroxyapatite only group, inflammatory cell infiltration was prominet and dense connective tissue were encapsulated around grafted materials. osteoblastic activity in the early stage after surgery was low to compared with grafted with bone cells. 3. In the case of porous hydroxyapatite inoculated with bone cell, less inflammatory cell infiltration and rapid new bone formation activity was revealed than hydroxyapatite only group. Active new bone formation were observed in the early stage of control group. 4. The origin of new bone forming was revealed not from the center of defected area but from the surface of preexisting bony wall on every specimen. 5. In this experiment, osteoclastic cell was not found around grafted materials, and fibrovascular invasion into regions with no noticeable foreign body reaction. Conclusively, the cultured bone cell inoculated onto the porous hydroxyapatite may have an important role of regeneration of artificial bone defects of alveolar bone.

  • PDF

개 퇴행성 관절염 모델을 이용한 연골과 활액 내 단백질 분해 효소와 억제제의 작용 연구 (Proteinases and their Inhibitors in Cartilage and Synovial Fluid Acquired from a Canine Osteoarthritic Model)

  • 설재원;이해범;김남수;이영훈;강형섭;김인식;박상열
    • 한국임상수의학회지
    • /
    • 제26권2호
    • /
    • pp.144-149
    • /
    • 2009
  • 퇴행성관절염(Osteoarthritis,OA)은 관절 부위의 퇴행성 변화가 특징이며, 이를 진단하기 위해서는 연골세포나 활액에서 유래된 표지인자가 일반적으로 사용된다. 이번 연구에서는 개를 이용하여 실험적으로 퇴행성관절염을 유도하고, 활액과 연골세포에서 단백질 분해 효소인 matrix metalloproteinase(MMPs)와 MMPs의 활성을 억제시키는 것으로 알려진 tissue inhibitors of metalloproteinases(TIMPs)의 발현 정도를 조사하였다. 20마리의 비글견이 퇴행성관절염 모델로 사용되었으며 MMP-2 와 -9은 Western blot 분석에 의해서, TIMP-2의 농도는 ELISA(enzyme-linked immunosorbent assays)에 의해 결정하였다. 퇴행성관절염 유도 4주 후에 연골에서 분리한 연골세포에서 MMP-2의 발현은 증가되었지만 MMP-9의 발현은 감소되었다. 그러나, 퇴행성관절염을 유도한 개의 활액에서는 MMP-2와 -9의 발현이 모두 증가하는 것을 보였다. TIMP-2의 농도는 퇴행성관절염을 유도한 연골에서 분리한 연골세포에서는 높았지만, 활액에서는 낮은 농도를 보였다. 이러한 결과는 MMP-9가 퇴행성관절염 시 연골 조직의 변성에 따른 연골세포의 손상에 의해 MMP-2보다 더 활액으로 방출된다는 것을 보여주며, 활액 내 TIMP-2의 감소에 따른 MMPs의 활성이 퇴행성관절염을 더욱 악화시키는 것을 제안해준다. 결국 MMPs의 활성은, 특히 MMP-9, 개의 퇴행성관절염의 조기 진단과 치료를 위한 표지인자로서 사용할 수 있을 것으로 사료된다.

척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가 (Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model)

  • 성윤상;윤성호;박재순;김희경;장용민;구세광;박현정;장광호
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.546-552
    • /
    • 2010
  • 대부분 척수손상 모델에서의 척수 손상 정도 평가는 자기공명 영상 등을 통한 유발 후 평가를 실시하고 있으며, 유발 전 평가를 위해 풍선 카테타에 주입된 공기 양을 기준한 예가 있으나 종 특이성과 개체 차이를 고려하지 못하는 단점이 있다. 이러한 단점을 극복한 척수손상 기준모델을 제시하기 위해 본 실험을 실시하였다. 방사선 평가를 통해 요추 1 번 척수강 높이가 8 mm로 측정된 임상적으로 건강한 비글견 8 마리를 풍선카테타의 직경과 척수 압박시간을 기준으로 4개 군 (4 mm/3 시간, 4 mm/6 시간, 4 mm/12 시간 그리고 6 mm/3 시간)으로 구분하였다. 손상 정도는 행동 관찰, 자기공명영상 해석, 체성감각유발전위평가 그리고 병리조직검사를 실시하여 평가하였다. 실험결과, 행동평가와 체성감각유발전위평가는 단지 손상 유발 여부만 지시할 뿐 정도 평가에는 유용하지 못하였다. 자기공명영상 평가에서 척수손상 부위는 단시간반전회복영상과 T2강조영상에서 불균질한 고신호강도 영역으로 관찰되었다. 고신호강도 영역은 삽입된 풍선 직경과 압박시간 증가에 따라 보다 확장되어 관찰되었으며, 이러한 소견은 공포화 등의 손상부위 증가와 카스파제-3 및 PARP 면역반응 세포의 수적 증가로 나타난 병리조직검사 결과와 일치하였다. 이러한 결과로 미루어 정형화된 척수손상 모델 유발을 위한 척수강 직경과 풍선카테타 직경 그리고 압박시간의 변수 이용과 손상 정도 평가를 위해 자기공명영상은 매우 유용할 것으로 판단된다.

생체내 혈중 납 표준물질의 제조 (In Vivo Preperation of Standard Reference Materials of Lead in Blood)

  • 정규철;최호춘
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권4호
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF